ページ1に含まれる内容の要旨
30X Crisp Image Detection
PTZ Dome Camera SPD-3000/2300 User’s Manual
Thank you for purchasing a SAMSUNG CCD CAMERA.
SALES NETWORK
Before attempting to connect or operate this product,
• SAMSUNG TECHWIN CO., LTD.
145-3, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, 462-120, Korea
please read these instructions carefully and save this manual for future use.
TEL : +82-31-740-8151~8158 FAX : +82-31-740-8145
• SAMSUNG OPTO-ELECTRONICS UK, LTD.
Samsung House, 1000 Hillswood Drive, Hillswo
ページ2に含まれる内容の要旨
The lightning flash with an arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. INFORMATION -Th
ページ3に含まれる内容の要旨
ENGLISH Samsung Techwin cares for the environment at all product manufacturing Features stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents Samsung Techwin s will to create environment-friendly products, and indicates that the product satisfies the EU RoHS Directive. 30X/23X Zoom Lens with Auto- Day & Night Focus Function The 30X/23X zoom lens having Auto-focus Day & Night function of ICR (IR Cu
ページ4に含まれる内容の要旨
ENGLISH ENGLISH Contents 8 Precautions 30 Functional Description OSD Menu Organization 30 Dome Camera User Menu Settings 34 10 Part Names and Functions 1. Camera Settings 34 Body 10 2. Sequence Setting 42 Camera Holder 11 3. P/T Setting 48 Camera Holder Connection 12 4. OSD Setting 51 Camera Holder Initial Setting 13 5. Alarm Setting 54 6. Initialization Setting 56 7. Status 57 22 Components and Accessories 58 Product Structure and Installation 23 Installation 62 Specifications
ページ5に含まれる内容の要旨
ENGLISH ENGLISH Precautions Installation by unqualified If any unusual odors or smoke comes Do not install the product in too Do not install the camera in persons is not recommended. from the camera, stop using the product. hot or too cold environments. intermittent lighting environments. Experienced and skilled technicians have to install It may cause fire. Do not use the camera under extreme temperatures (below - Do not install the camera under severely this product. Unqualified and personal i
ページ6に含まれる内容の要旨
ENGLISH Part Names and Functions Body Camera Holder 9. 1N.C 8. 1N.O Function Setup Switch 1. Half/Full 2.3.4.5. RS-485/422 Terminal Setting Power Switch 6. RS-485/422 Communication 7. Factory setting 8. RS-232 Power ON/OFF (Factory Setting: OFF) Controller Connection Input 1. RXD+ 2. RXD- 3. TXD+ 4. TXD- 5. GND 6. TX 7. RX ID Setup Switch Alarm Connection Input 1. IN1 2. IN2 3. GND 4. IN3 5. IN4 6. GND 7. COM1 8. 1N.O 9. 1N.C 10. COM2 11. 2N.O 12. 2N.C Protocol Selection S
ページ7に含まれる内容の要旨
ENGLISH Part Names and Functions Camera Holder Connection Camera Holder Initial Settings Setting Communications Protocol Use the SW3 of installation bracket to set the communications protocol. SW3 Protocol Baud Rate(BPS) 0 Samsung 9,600 1 Samsung 19,200 2 Pelco-D 2,400 3 Pelco-D 4,800 4 Pelco-D 9,600 5 Pelco-P 4,800 6 Pelco-P 9,600 7 Samsung Elec. 9,600 8 Samsung Elec. 19,200 9 Panasonic 9,600 A Panasonic 19,200 B Vicon 4,800 C Vicon 9,600 D Honeywell 9,600 E AD 4,800 F Bosch 9,600 Notes • If t
ページ8に含まれる内容の要旨
ENGLISH ENGLISH Part Names and Functions Setting Baud Rate Based on DVR Model (Camera Holder) Setting Camera ID Switch (Camera Holder) Camera ID SW2 SW1 Remarks Camera ID SW2 SW1 Remarks If the speed dome camera is controlled not by the camera controller but by a ID = 0 0 0 N/A ID = 48 3 0 ID = 1 0 1 ID = 49 3 1 DVR, set the communication speed based on the DVR model as follows. ID = 2 0 2 ID = 50 3 2 ID = 3 0 3 ID = 51 3 3 Protocol Samsung Pelco Samsung Elec. ID = 4 0 4 ID = 52 3 4 DVR Model I
ページ9に含まれる内容の要旨
ENGLISH Part Names and Functions Camera ID SW2 SW1 Remarks Camera ID SW2 SW1 Remarks Camera ID SW2 SW1 Remarks Camera ID SW2 SW1 Remarks ID = 96 6 0 ID = 146 9 2 D = 196 C 4 ID = 246 F 6 ID = 97 6 1 ID = 147 9 3 ID = 197 C 5 ID = 247 F 7 ID = 98 6 2 ID = 148 9 4 ID = 198 C 6 ID = 248 F 8 ID = 99 6 3 ID = 149 9 5 ID = 199 C 7 ID = 249 F 9 ID = 100 6 4 ID = 150 9 6 ID = 200 C 8 ID = 250 F A ID = 101 6 5 ID = 151 9 7 ID = 201 C 9 ID = 251 F B ID = 102 6 6 ID = 152 9 8 ID = 202 C A ID = 252 F C ID =
ページ10に含まれる内容の要旨
ENGLISH Part Names and Functions The following 3 Camera ID’s cannot be used. Notes Camera ID R-SW2 R-SW1 • Factory Settings: OFF ID = 0 0 0 ID = 160 A 0 ID = 175 A F Setting Communication Method (Camera Holder) Function ON OFF Setting Transmission Mode (Camera Holder) SW3- #6 Factory Release RS-422 RS-485 Set the transmission mode using the ON/OFF of the Dip Switch 1. Notes • Factory Setting: OFF Setting for Factory Adjustment (Camera Holder) Function ON OFF Function ON OFF SW3- #1 Transmissio
ページ11に含まれる内容の要旨
ENGLISH Part Names and Functions Controller Connection Terminal (Camera Holder) Setting Termination Resistance In order to prevent signal reduction, the termination resistance of the 2 end NAME Purpose units, which are the distant paths for camera and controller to be connected CON7- #1 RXD+ Controller Data Line Connection on the RS485 interface, should be connected. CON7-#2 RXD- Controller Data Line Connection As the termination resistance is built in the camera, whether to make the CON7-#3 T
ページ12に含まれる内容の要旨
ENGLISH ENGLISH Components and Accessories Installation Accessories Preparation for Cable To install and use the SPD-3000/2300, the following cables should be used. • Power Adapter Cable The cable connected to the power input terminal of SPD-3000/2300 is shown below with a rated voltage of AC24V 2.5A. Adapter AC24V, Peak 2.5A) User s Manual Camera Holder 3 Screws for Fastening Camera Holder Terminal Block for Controller Terminal Block for Alarm Safety wire Connection (7Pin) Connection (12Pin)
ページ13に含まれる内容の要旨
ENGLISH Installation Cable Connection Installation of SPD-3000/2300 1. First, connect one end of the BNC video Monitor In Terminal Video Out Terminal • Installation Precautions cable connector to the Video Output - Check out the installation place. It should be strong enough to support more Terminal. than 4 times the total product weight including speed dome camera (SPD- 3000/2300) and installation structure. 2. Next, connect the other end of the - Install the camera in a place having more tha
ページ14に含まれる内容の要旨
ENGLISH Installation 3) Indoor and Outdoor Housing (STH-330PI, STH-330PO) Camera Installation (outdoor Housing) This housing is used to install the speed dome camera on the indoor or outdoor 1. Fasten the ceiling mount on the ceiling. wall or ceiling. (For the indoor type, the fan and heater are excluded.) 2. Pull outside of the housing the safety wire fastened to the outdoor housing. 4) Wall Type Mount (STB-270PW) This item is used to install the indoor or outdoor housing for speed dome on th
ページ15に含まれる内容の要旨
ENGLISH Installation 5. Connect the heater and fan cables within the 9. Connect the housing safety wires to the fixture housing to the fan heater PCB. inside the mount installed on the ceiling. 6. Adjust and make the arrows marked on 10. Connect the video cable, the controller cable, the bottom of the camera an arrow the power adapter cable and ID cable to body face each other. the camera holder. 11. Check out the connection of all parts and 7. Insert the camera into the housing by matc
ページ16に含まれる内容の要旨
ENGLISH Functional Description P1 P2 P3 P4 Defaults OSD Menu Organization Sync Line Lock Line Lock Phase 225 Stabilizer On/Off OFF Dome camera can be set up on the OSD (On Screen Display) menu displayed Camera Others Sharpness 008 Image Adj. on the video monitor by the camera controller. The joystick operations in the Setting Color 050 OSD menu are as follows. In addition, sending control codes to the camera from Freeze On/Off OFF the PC can also use the camera functions. Preset Setting Edit
ページ17に含まれる内容の要旨
ENGLISH Functional Description P1 P2 P3 P4 Defaults Notes Area5 Area Name Area6 • Preset setting is only possible on the OSD menu or using the controller. Area Setting Position Area7 ON/OFF Area8 P/T Mask1 Setting Mask2 Position Area Masking Mask3 ON/OFF Symbol Description Mask4 1. Motion Stabilization Stand-by Operation Prop. P/T ON / OFF ON Digital Flip ON / OFF ON - “D” symbol is flashing on the right top of the screen. Camera ID ON / OFF ON 2. Alarm operation Camera Name Edit ON / OFF - “
ページ18に含まれる内容の要旨
ENGLISH Functional Description Dome Camera User Menu Settings FOCUS • Execution of OSD Menu : In Focus menu, you can set up the focus mode among Auto, Manual or One After checking if the camera is in manual operation mode, press the OSD Menu Shot AF. key or 1+MENU (SCC-16 Model). The following commands are displayed on the Focus Mode monitor screen. Auto : The camera adjusts the focus automatically while monitoring the screen continuously in the auto mode. In the auto focusing mode, • Main M
ページ19に含まれる内容の要旨
ENGLISH Functional Description Exposure White Balance The White Balance function corrects the abnormal white colour into the Camera exposure can be controlled. normal white colour under any colour temperature lighting. Camera Setting Exposure Select the mode among ATW, AWC and Manual. ATW is selected by default. Focus Brightness 050 White Balance ATW(O) Iris AUTO Camera Setting Exposure Shtter --- Focus Back Light OFF Sens-Up AUTO White Balance ATW(O) AGC MIDDLE Exposure SSNR MIDDLE Back Ligh
ページ20に含まれる内容の要旨
ENGLISH Functional Description Sens-Up Camera Setting Camera Setting Auto: The low light level of the night or dark condition is detected automatically Focus Focus White Balance ATW(O) White Balance ATW(O) and the bright and clear image can be maintained. Exposure Exposure Sens-Up Limit: Maximum accumulated magnification can be selected. Back Light OFF Back Light OFF AGC MIDDLE AGC OFF Off: Sens-Up function is cancelled. SSNR MIDDLE SSNR MIDDLE Day & Night COLOR Day & Night COLOR Notes Others