TABLE OF CONTENTS PAGE PAGE 1 Safety Precaution -------------------------------------------------3 1.1. General Guidelines ----------------------------------------3 1.2. Leakage Current Cold Check ---------------------------3 1.3. Leakage Current Hot Check (See Figure 1.)--------3 1.4. How to Discharge the Capacitor on Power/Top PCB------------------------------------------------------------4 2Warning --------------------------------------------------------------5 2.1. Prevention of Electro Stat
ページ3に含まれる内容の要旨
1 Safety Precaution 1.1. General Guidelines 1.3. Leakage Current Hot Check 1. IMPORTANT SAFETY NOTICE (See Figure 1.) There are special components used in this equipment 1. Plug the AC cord directly into the AC outlet. Do not use which are important for safety. These parts are marked by an isolation transformer for this check. 2. Connect a 1.5 k Ω, 10 W resistor, in parallel with a 0.15 μF in the Schematic Diagrams, Circuit Board Layout, capacitor, between each exposed metallic part on the set E
ページ4に含まれる内容の要旨
1.4. How to Discharge the Capacitor on Power/Top PCB CAUTION: 1. Be sure to discharge the capacitor on POWER/TOP PCB. 2. Be careful of the high voltage circuit on POWER/TOP PCB when servicing. [Discharging Procedure] 1. Refer to the disassemble procedure and Remove the necessary parts/unit. 2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k Ω /5W). (an equivalent type of resistor may be used.) 3. Put the resistor between both terminals of capacitor on POWER/TOP PCB for appro
ページ5に含まれる内容の要旨
2Warning 2.1. Prevention of Electro Static Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Elec- trostatically Sensitive (ES) Devices. The following techniques should be used to help reduce the incidence of component damage caused by electro static discharge (ESD). 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain
ページ6に含まれる内容の要旨
2.3.2.1. Important 2.3. Caution for AC Cord The wires in this mains lead are coloured in accordance with (For EB/GC/SG) the following code: 2.3.1. Information for Your Safety Blue Neutral IMPORTANT Brown Live Your attention is drawn to the fact that recording of pre- recorded tapes or discs or other published or broadcast As the colours of the wires in the mains lead of this appliance material may infringe copyright laws. may not correspond with the coloured markings identifying the WARNING term
ページ7に含まれる内容の要旨
2.4. How to Replace the Lithium Battery 2.4.1. Replacement Procedure 1. Remove the POWER/TOP PCB. (Refer to Disassembly Procedures.) 2. Remove the Lithium battery (Ref. No. “Z9901” at component side of POWER/TOP PCB) and then replace it into new one. NOTE: This Lithium battery is a critical component. (Type No.: ML-421S/ZT Manufactured by Matsushita Battery Industrial Co.,Ltd.) It must never be subjected to excessive heat or discharge. It must therefore only be fitted in requirement designed sp
ページ8に含まれる内容の要旨
NOTE: Above caution is applicable for a battery pack which is for DMC-TZ1 series, as well. 8
ページ9に含まれる内容の要旨
3 Service Navigation 3.1. Introduction This service manual contains technical information, which allow service personnel’s to understand and service this model. Please place orders using the parts list and not the drawing reference numbers. If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual. 3.2. General Description About Lead Free Solder (PbF) The lead free solder has been used in the mounting process of all el
ページ10に含まれる内容の要旨
3.4. How to Define the Model Suffix (NTSC or PAL model) There are six kinds of DMC-TZ1, regardless of the colours. • a) DMC-TZ1S • b) DMC-TZ1PP • c) DMC-TZ1EB/EF/EG/EGM/GN • d) DMC-TZ1EE • e) DMC-TZ1GT • g) DMC-TZ1PL/GC/GK/SG (DMC-TZ1S is exclusively Japan domestic model.) What is the difference is that the “INITIAL SETTINGS” data which is stored in Flash ROM mounted on Main PCB. 3.4.1. Defining methods: To define the model suffix to be serviced, refer to the nameplate which is putted on the bot
ページ11に含まれる内容の要旨
3.4.2. INITIAL SETTINGS: When you replace the Main PCB be sure to perform the initial settings after achieving the Adjustment, by ordering the following pro- cedure in accordance with model suffix. • Step 1. The temporary cancellation of factory setting: Set the mode dial to “[ Normal picture mode ] (Red camera mark)”. While keep pressing [ Optical Image Stabilizer ] and “[ UP ] of Cross key” simultaneously, turn the Power on. • Step 2. The cancellation of factory setting: Set the mode dial to
ページ12に含まれる内容の要旨
4 Specifications 12
ページ13に含まれる内容の要旨
5 Location of Controls and Components 13
ページ14に含まれる内容の要旨
6 Service Mode 6.1. Error Code Memory Function 1. General description This unit is equipped with history of error code memory function, and can be memorized 32 error codes in sequence from the latest. When the error is occurred more than 32, the oldest error is overwritten in sequence. The error code is not memorized when the power supply is shut down forcibly (when the unit is powered on by the battery, the battery is pulled out) because the error code is memorized to FLASH ROM when the unit is
ページ15に含まれる内容の要旨
• 4. How to read the error code: One error code is displayed for 8 bit, the contents of error codes is indicated the table as shown below. Attribute Main item Sub item Error code Contents (Upper) High 4 bits Low 4 bits Check point (Lower) LENS Lens drive OIS 1800 1000 PSD (X) error. Hall element (X axis) position detect error in OIS unit. OIS Unit 2000 PSD (Y) error. Hall element (Y axis) position detect error in OIS unit. OIS Unit 3000 GYRO (X) error. Gyro (IC7101: X axis) detect error on Main
ページ16に含まれる内容の要旨
Attribute Main item Sub item Error code Contents (Upper) High 4 bits Low 4 bits Check point (Lower) LENS Adj.History OIS 1900 2000 OIS adj. Yaw direction amplitude error (small) OIS Unit, LENS flex breaks. 3000 OIS adj. Pitch direction amplitude error (small) OIS Unit, LENS flex breaks. 4000 OIS adj. Yaw direction amplitude error (large) OIS Unit, LENS flex breaks. 5000 OIS adj. Pitch direction amplitude error (large) OIS Unit, LENS flex breaks. 6000 OIS adj. MREF error OIS Unit, LENS flex break
ページ17に含まれる内容の要旨
6.2. Confirmation of Firmware Version The Firmware version can be confirmed by ordering the following steps:. • Step 1. The temporary cancellation of factory setting: Set the mode dial to “[ Normal picture mode ] (Red camera mark)”. Insert the SD memory card which has a few photo data. While keep pressing [ Optical Image Stabilizer ] and “[ UP ] of Cross key” simultaneously, then turn the power on. • Step 2. Confirm the version: Set the mode dial to “[ Playback ]” and then press [ DISPLAY ] to
ページ18に含まれる内容の要旨
7 Service Fixture & Tools 7.1. Service Fixture and Tools The following Service Fixture and tools are used for checking and servicing this unit. 18
ページ19に含まれる内容の要旨
7.2. When Replacing the Main PCB After replacing the MAIN PCB, be sure to achieve adjustment. The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in “TSN system”, together with Maintenance software. 7.3. Service Position This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing. Table S1 Extension Cable List No. Parts No. Connection Form 1 VFK1950 FP6501 (SD/AFE) -CCD UNIT
ページ20に含まれる内容の要旨
8 Disassembly and Assembly Instructions 8.1. Disassembly Flow Chart 8.2. PCB Location 20