ページ9に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Parts and their function =Guide pin END/EXT connector [ND/EXT] Use this to determine the direction in which the camera is This is for the control of the ND filter and lens extender of to be mounted. the motorized lens unit. Connect this connector when using a motorized lens unit with ND filter and lens extender functions. >Camera mounting screws (U1/4” 20UNC) The compatible connector is the R03-P6M or R03-PB6M These are used to secure the camera firmly after it has
ページ10に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Parts and their function JY connector [Y] This is the output connector for the camera’s video signals. It is connected to the Y/VIDEO connector on the AW-RC400 cable compensator or monitor, etc. Use a BNC coaxial cable for the connecting cable. The AW-PB302 RGB card must be installed if the AW-E300, AW-E300A, AW-E600, AW-E800 or AW-E800A convertible camera is to be used. K1394 connector [1394] This is used for the control of the convertible camera and pan/tilt h
ページ11に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Assembling the pan/tilt head 1Attaching the camera mounting base Attach the camera mounting base to the rotary arm using the three screws. The mounting direction differs depending on the installation method used. For installation on the ceiling 2Attaching the rotary arm Attach the rotary arm to the rotary head using the four screws. The mounting direction differs depending on the installation method u
ページ12に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Setting the mounting direction switch Set the switch as follows when the unit is to be installed on the ceiling. (This switch was set to the stand-alone installation position at the factory.) 1 Remove the four screws, and gently remove the pedestal connector panel. 2 Set switch S1 on the PCB inside the pan/tilt head as follows. For stand-alone installation: Set S1 to the rear position (T). (Factory se
ページ13に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Setting the PCB switches The switches on the CONNECTOR PCB will need to be set in accordance with the signals to be transmitted and the equipment to be connected to the pan/tilt head. (The switches are set to support analogue/SDI at the factory.) ≥ Analogue/SDI support IP/IEEE switch: IEEE 422/IP switch: 422 ≥ Web card support IP/IEEE switch: IP 422/IP switch: IP ≥ IEEE1394 card support IP/IEEE switch
ページ14に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Changing the mounting position of the pedestal connector panel If necessary, the position at which the pedestal connector panel is mounted can be moved to the opposite side of the unit. Rotary head connector panel Side blank panel Pedestal connector panel (opposite side) 1 Remove the four screws for the pedestal connector panel, and pull out the pedestal connector panel. 2 Disconnect all six connector
ページ15に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Installing the pan/tilt head When installing the pan/tilt head, follow the instructions below carefully. In order to prevent accidents resulting when the product becomes dislodged or falls down, be absolutely sure to proceed as instructed. Do not install the pan/tilt head on its side since its prescribed operation and performance cannot be ensured. ≥ After the pan/tilt head has been installed, mount t
ページ16に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Mounting the camera 1 Select the positions of the guide pin and camera mounting screws in accordance with the camera and lens to be used, and mount the camera. When mounting the camera on the pan/tilt head, be very careful to ensure that the camera does not fall off or fall down. For a stand-alone installation Guide pin Flat washers Camera mounting screws For installation on the ceiling Guide pin Flat
ページ17に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Attaching the chain When mounting the AW-E750 camera 1 Use the chain mounting screw (M4!8 mm with flat washer and spring washer) to attach one end of the chain to the pan/tilt head’s arm. 2 Mount the mounting spacer on the top panel of the camera. 3 Use the chain mounting screw (M4!6 mm with flat washer and spring washer) to attach the other end of the chain to the screw hole of the mounting spacer. W
ページ18に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Replacing the consumable parts $ Replacing the battery The battery has a service life of approximately 5 years. The unit stores the preset positions, limiters and other data in its memory. This data is retained even when the power is turned off, but if the internal battery has reached the end of its service life, the data will be lost when the power is turned off. Replace a battery that has lost its charge with a new one. (Battery used: CR2032 manganese dioxide-lit
ページ19に含まれる内容の要旨
Indoor Pan/Tilt Head AW-PH400 Specifications Supply voltage: AC 240V, 50/60 Hz Power consumption: 145W 1 indicates safety information. Genlock input: BNC Black burst or composite video signal Prompter input (PROMPTER IN): BNC Through output to PROMPTER connector Prompter output (PROMPTER OUT): D-SUB 15-pin Camera video output VIDEO: BNC, 75-ohm output, 1 Vp-p Connecting cable: 5C-2V, max. 1000 meters Y, Pr/C, Pb: Y/C Y: 1 Vp-p/75 ohms C: 0.285Vp-p/75 ohms (burst) Component video: Y: 1 Vp-p/75 o
ページ20に含まれる内容の要旨
Pan/Tilt Head Controller AW-RP400 Introduction ≥ This pan/tilt head controller enables up to five AW-PH400 NOTE indoor pan/tilt heads to be controlled. ≥ The AW-RP400 cannot be used to control the model ≥ By connecting the AW-CB400 remote operation panel or AW-PH300, AW-PH300A, AW-PH350, AW-PH500 or WV-CB700A remote control box to the controller, the AW-PH600 pan/tilt heads. convertible cameras mounted on the pan/tilt heads can be ≥ Before using the controller, the movement range controlled at