ページ1に含まれる内容の要旨
MEGAPIXEL IP CAMERA
INSTRUCTIONS
VN-X35U
Thank you for purchasing this JVC product.
Before operating this unit, please read the
instructions carefully to ensure the best
possible performance.
LST0789-001A
ページ2に含まれる内容の要旨
Getting Started Safety Precautions Information for Users on Disposal of Old Equipment [European Union] This symbol indicates that the electrical and electronic equipment should not be disposed as general household waste at its end-of-life. Instead, the product should be handed over to the applicable collection point for the recycling of electrical and electronic equipment for proper treatment, recovery and recycling in accordance with your national legislation. By disposing of this product c
ページ3に含まれる内容の要旨
● This installation should be made by a Due to design modifications, data given in this qualified service person and should conform instruction book are subject to possible change to all local codes. without prior notice. ● This installation shall be in accordance with the National Electrical Code, ANSI/NFPA 70. WARNING: ● The unit is to be powered by an AC 24 V TO REDUCE THE RISK OF FIRE OR power supply. ELECTRIC SHOCK, DO NOT The AC 24 V power supply should conform to the following:Class
ページ4に含まれる内容の要旨
Getting Started These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances. IMPORTANT SAFEGUARDS 1. Read all of these instructions. 2. Save these instructions for later use. 3. All warnings on the product and in the operating instructions should be adhered to. 4. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5. Do not use attachments not recommended by the appliance
ページ5に含まれる内容の要旨
Setting Using Internet Explorer Contents When the IP address of VN-X35U is known ........................................ 33 Getting Started When the IP address of VN-X35U Safety Precautions ..................................... 2 is unknown .................................... 33 Contents ..................................................... 5 Setup ........................................................ 33 Main Features ............................................. 6 Internet Explorer Setup
ページ6に含まれる内容の要旨
Getting Started Main Features Privacy Mask Feature You can configure the privacy mask setting to hide specific area in shooting area. High Picture Quality The camera unit of this product employs a Motion Detection 1,250,000-pixel CCD (1/3") which enables high This feature enables output of an alarm upon quality video surveillance. detection of motion in the video image within preset area. Support for Dual Stream Pre-/Post-recorded image files may be sent via Simultaneous distribution of JP
ページ7に含まれる内容の要旨
How to use this manual Operating Environment Symbols used Recommended Computer Caution : Describes precautions concerning Specifications the operation of this product. OS : Windows XP (Professional or Note : Describes reference information, Home Edition) (SP2) such as functions and usage : Windows Vista Business(SP1) restrictions of this product. CPU : Pentium4 2GHz or higher A : Indicates the reference page Memory capacity : 1 GB or more numbers and reference items. Free hard disk spa
ページ8に含まれる内容の要旨
Getting Started Cautionary Notes Saving Energy When this product is not in use for a long period of time, turn off the power of the Maintenance and location of use system to ensure safety and reduce power consumption. This product is intended for use indoors. Make sure that you use a housing etc., when using it outdoors. Maintenance Do not place this product in the following Be sure to turn off the power before environments. performing maintenance. Otherwise, it may malfunction or
ページ9に含まれる内容の要旨
If the power supply voltage is momentarily Others cut off or reduced due to lightning, turning on of the air conditioner’s power, etc., the image The cable stopper of the alarm terminal may may be disrupted or noise interference may come off in some cases. When mounting the occur. cables, make sure to do so carefully. When using multicast, make use of a If a high luminance object (such as a lamp) is IGMPv2-compliant network switch. shot, a white smear may appear at the upper and
ページ10に含まれる内容の要旨
Getting Started Name and Function of Parts Front / Bottom / Side H A G F B E C D I A Back Focus Adjustment Ring F [MAC address]Indicator This ring is used for adjusting the back focus. The MAC address is a unique physical address of the product. This address cannot be altered. To operate, loosen the H back focus fastening screw by turning it in the anti-clockwise direction, G Camera Mounting Bracket and turn the screw in the clockwise direction to This bracket is pre-mounted to the bottom fa
ページ11に含まれる内容の要旨
Side JK MONITOR OUT PAL OFF NTSC RESET STATUS IRIS M L J [MONITOR OUT] Monitor Output Selection Memo: Switch Pressing and holding the button for five seconds or longer enables the service confirmation Use this switch to select the availability of output mode. The L [STATUS] indicator lights up in from the N [MONITOR OUT] terminal as well as orange color in this mode. Do not press the the signal system.(A Page 12) button for 5 seconds or l
ページ12に含まれる内容の要旨
Getting Started Name and Function of Parts (continued) Rear R S N O N [MONITOR OUT] Monitor Video Signal P [ALARM INPUT/OUTPUT] Alarm Input/ Output Terminal (RCA) Output Terminals This is an output terminal for composite video Use these terminals to connect to an external signals (1 V (p-p), output impedance of 75 K). alarm device. Use this terminal to connect to devices such as a (A Page 20) video monitor. Q [AC24V] Power Input Terminal This terminal is used for adjusting the camera angle du
ページ13に含まれる内容の要旨
Features Surveillance via Dual Stream Simultaneous distribution of JPEG and MPEG4 images enables real-time surveillance using Surveillance Using Built-in Viewer MPEG4 (30 fps) and recording of JPEG images at the same time. You can also lengthen the VN-X35U comes with Built-in JPEG/MPEG4 recording time by lowering the frame rate, Viewer and Audio Monitor. resolution, and picture quality settings for JPEG JPEG images and MPEG4 images of VN-X35U images. can be monitored using Built-in Viewe
ページ14に含まれる内容の要旨
Getting Started Alarm Device VN-X35U Features (continued) MAC address Input audio to computer / output audio from computer Connect the mini jack R3.5 stereo cable to the [AUDIO IN/OUT] terminal. Connect an external Network microphone to the R ch of the mini jack R3.5 stereo cable. You can now monitor audio sound Computer Sending JPEG images that has been picked up such as on a computer. before and after alarm Connect the built-in amplifier speakers to the Lch input to FTP to output aud
ページ15に含まれる内容の要旨
Setup Procedures Step 1 Connection/Installation (A Page 16) Connect the lens mount, power supply cord, LAN cable and alarm cable. Next, mount the camera to the ceiling. Make sure to attach the fall prevention wire firmly to the camera. After the camera is mounted, connect the video monitor to the [MONITOR OUT] terminal at the rear of the unit, followed by adjusting the camera angle. You can select the video signals of the [MONITOR OUT] terminal using the [MONITOR OUT] switch. (ANTSCBor A
ページ16に含まれる内容の要旨
Connection / Installation 3. When using a DC iris lens, pay attention Mounting the Lens to the pin position before connecting the lens cable Note: ● Make use of a megapixel lens. 2. MONITOR OUT PAL OFF NTSC RESET 1. Check the mounting method of the lens to STATUS be used before mounting ● The mount method used for VN-X35U is CS IRIS mount. ● Make use of the values listed in the table 3. 1 3 below for the dimensions of the lens mount (a)
ページ17に含まれる内容の要旨
Power Connection MONITOR OUT PAL OFF NTSC RESET Electricity can be supplied to this product either STATUS by connecting to the AC 24 V power supply or using the PoE (A Page 18). When power is supplied to this product, the IRIS [STATUS] indicator at the side lights up. The indicator lights up in orange color during startup, and switches to green color after startup is complete. [STATUS] Indicator Memo: Power cord You can select not t
ページ18に含まれる内容の要旨
Connection / Installation Power Connection (continued) LAN Cable Connection ● In a system where multiple units of VN-X35U Connect the camera to a hub or computer using are used, turn on the power of only one unit a LAN cable. to configure the IP address settings using the Internet Explorer. Upon doing so, turn on the Cable to use power of the second unit and configure ● Shielded cable accordingly. Configure the camera settings ● Length of 100 m or shorter using the same procedure. ● When t
ページ19に含まれる内容の要旨
Monitor Signal Output Terminal Audio Signal Input/Output Connection Terminal Connection Make use of this terminal for camera angle Connect the mini jack R3.5 stereo cable. adjustment during installation or focus L ch : Connect to speakers with built-in adjustment in the Focus Assist mode. Connect it amplifier, etc. to devices such as a video monitor using a video cable (RCA). R ch : Connect to plug-in power type capacitor microphone Memo:
ページ20に含まれる内容の要旨
Connection / Installation Sensor Example VN-X35U Alarm Input/Output Terminal (1) DC3.3 V INPUT 1 or VCC Connection 2 Terminal R R OUT Connect the alarm input/output terminals with external devices, such as a sensor or buzzer. 3.3 V 1 mA Plug/Unplug the cable while pressing the button G Terminal GND as shown in the diagram below. (Alarm Input Equivalent Circuit) Sensor Example Cable to use (2) ● Shielded cable Relay Switch, etc. ● Length of 50 m or shorter OUT GND 1 2 G 21 21 AC24V ALARM Al