ページ1に含まれる内容の要旨
MFCD 1219 (TS)
User Manual
ページ2に含まれる内容の要旨
(This page intentionally left blank.) 2
ページ3に含まれる内容の要旨
Copyright notice This document is copyrighted. All rights are reserved. Nor this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems - without written permission of Barco © 2010 Barco N.V. All rights reserved. 3
ページ4に含まれる内容の要旨
Table of Contents Table of Contents Preface ................................................................................................. 5 Environmental information.......................................................... 7 Safety Instructions........................................................................ 7 Recommendations for using your display system ................... 10 Overview............................................................................................ 12 Int
ページ5に含まれる内容の要旨
Preface Preface Notice Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know. BarcoView software products are the property of BarcoView. They are distributed under copyright by Barco N.V. or BarcoView, LLC., for use only under the specific terms of a software license agreement
ページ6に含まれる内容の要旨
Preface reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Canadian notice This Class B di
ページ7に含まれる内容の要旨
Preface Environmental information Disposal Information The lamps inside the display contain mercury. Do not throw the display in the trash. Dispose of it as required by local ordinances or regulations. This equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for health and environment. In order to avoid the dissemination of those substances in the environment and to diminish the pressure on natural resources, we encourag
ページ8に含まれる内容の要旨
Preface Electrical shock Type of protection (electrical): Class I equipment Degree of safety (flammable anesthetic mixture): Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. Power connection • Power requirements: The display must be powered using the 12 VDC power supply that is supplied with the display. • The 12 VDC power supply must be powered by the AC mains voltage. •Power cords: Power cord with CEE 7 plug: The colo
ページ9に含まれる内容の要旨
Preface Water and moisture Never expose the display to rain or moisture. Never use the display near water - e.g. near a bathtub, washbasin, swimming pool, kitchen sink, laundry tub or in a wet basement. Ventilation Do not cover or block the ventilation openings in the cover of the set. When installing the display in a cupboard or another closed location, heed the necessary space between the set and the sides of the cupboard. Installation Place the display on a flat, solid and stable surfa
ページ10に含まれる内容の要旨
Preface This apparatus conforms to: CE (LVD 73/23/EEC), IEC 60950-1, UL 60950-1, CAN/CSA C22.2 No. 60950-1 (c-UL), EN 60950-1 DEMKO, CCC GB4943-1995 National Scandinavian Deviations for Cl. 1.7.2 : Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan" Norway: "Apparatet må tilkoples jordet stikkontakt" Sweden: "Apparaten skall anslutas till jordat uttag" Recommendations for using your display system 1. Optimize the lifetime of your display Enabling the Display
ページ11に含まれる内容の要旨
Preface saver is not activated), change the image content regularly to avoid image retention of the static elements. 3. Understand pixel technology LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more a
ページ12に含まれる内容の要旨
Overview Overview Introduction The MFCD 1219 (TS), BARCO’s full color 19” LCD display, guarantees perfect image quality in medical imaging applications. The display combines a TFT (thin film transistor) liquid crystal display panel structure and a built-in backlight with inverter for a better picture quality. It is designed to meet users' needs for performance, consistency, and outstanding image quality through a streamlined development process in which wall-mount functionality provides a
ページ13に含まれる内容の要旨
Overview Touch panel The MFCD 1219 TS is equipped with a touch panel. Instructions on how to install and use the touch panel driver and controls can be found in the "TouchKit, Barco TouchScreen controller installation and user manual" on the supplied CD-ROM. Package contents The package should include the following items, please check. If some of the items are missing, please contact the reseller you have purchased the unit from. • The display with foot • 12V DC adapter • European power cor
ページ14に含まれる内容の要旨
Overview Controls and connectors 11 1 23 4 56 7 8 9 10 1. 12V DC power input 2. DVI input (DVI-D supported only) 3. Analog video input 4. USB port for touch panel connection to PC (MFCD 1219 TS only) 5. < (left) Key 6. > (right) Key 7. Menu key 8. Auto Key 9. Power LED The LED is off when the display is off. The LED is green when the display is on. The LED is orange when the display is in power-saving mode (stand-by) 10. Power key 11. Push-button to release the panel from the foot 14
ページ15に含まれる内容の要旨
Installation Installation Precautions • Keep your original packaging. It is designed for this display and is the ideal protection during transport. • Avoid reflections in the flat panel to reduce eye strain. • Place the display on a strong and stable table or desk. • Keep the display away from heat sources and provide enough ventilation in case it is built in a rack or console. Do not put in direct sunlight. • Make sure computer and display are switched off before connecting the signals. • T
ページ16に含まれる内容の要旨
Installation 2. Firmly press down the push-button (9) with one hand while carefully lifting the panel up with the other hand. 3. Remove the panel from the foot. Step 2: Fix the mounting plate to the wall 1. Screw the mounting plate to the wall with the 4 supplied screws (A). A 2. Slide back the locks at both sides of the mounting plate (B). In that way, you can secure the panel to the mounting plate after placing the panel. B Step 3: Place the panel on the mounting plate 1. Place the panel o
ページ17に含まれる内容の要旨
Installation Please make sure that the four shafts are securely placed in the notches of the mounting plate. C 2. To secure the panel, slide forward the locks on both sides of the mounting plate. Lock the panel with one screw at both sides (D). D Connecting the signals 12 3 17
ページ18に含まれる内容の要旨
Installation To connect the video & sync signals: 1. Connect one end of the appropriate video cable to the corresponding video input of the monitor. • Analog video: Connect to input (3) • DVI: Connect to input (2) 2. Connect the other end of the video cable to the video output of your video source. • Analog video: Computer graphics board with analog video output • DVI: Computer graphics board with digital video output To connect the power: 1. Connect one end of the proper power cable to the A
ページ19に含まれる内容の要旨
Installation 1 Note: The recommended resolution for best image quality is 1280x1024 at 60 Hz. The microcontroller in the display checks if the connected video signal has been adjusted before, and if these adjustments have been stored in the memory. There are 2 possibilities: a) The video signal has been adjusted and stored in the memory. In this case, the display switches to this memory location (the so- called mode) and the image will need no further adjustments. b) The video signal has not
ページ20に含まれる内容の要旨
Installation Install the software MediCal QAWeb Agent software: Insert the CD-ROM in the CD-ROM drive. The CD-ROM starts automatically. Please follow the instructions on the screen. The CD-ROM contains user instructions about the usage of the MediCal QAWeb Agent. Touch panel software: Please refer to the TouchKit installation & user manual on CD-ROM. 20