UNIVERSAL COOK’N’VENT
INSTALLATION INSTRUCTIONS
MODELS: UCV30 UCV36 UCV45
Rating: 120 Volt, 60 Hz., 10.0 Amps.
For Integral Blower Installations:
• Requires Integral Blower: Model # VTN600CVA
Requires Round Duct Size (6" Diam.)
Requires Dedicated Branch Circuit Power Supply 120 Volt AC
min. 15 Amps., 3 prong receptacle 60 Hz.
See Steps 3 and 5 for electrical receptacle and duct outlet location
For Remote Blower Installations:
Requires Remote Blower: Model # VTR1000Q or V
ページ2に含まれる内容の要旨
TABLE OF CONTENTS Safety Instructions ..............................................................................................................................................pg. 1 Introduction ..........................................................................................................................................................pg. 2 Step 1 Plan the Installation...............................................................................................................
ページ3に含まれる内容の要旨
Figure 1 Top Cap Filters Snorkel Blower Assembly J-Box Support Leg Wing Nuts INTRODUCTION GENERAL DESCRIPTION ® The complete Universal Cook‘n‘Vent System consists of the ventilator intake and a blower. See Fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the cooktop) or a remote (roof or outside wall mounted). When a remote blower is used, a duct transition is mounted on the ventilator intake in place of the integral blower to connect the intake to the d
ページ4に含まれる内容の要旨
STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below. See Figure 2. A. Determine whether a remote or integral blower will E. Provide "make-up air" to installation location to be used. Remote blower installation requires 5 improve performance and prevent problems, such as wires plus a ground wire to run from the fireplace chimney downdrafts. ® Cook‘n’Vent to the blower. F. Investigate potential ductwork routes and choose B. Make sure adequate cabinet and counter spa
ページ5に含まれる内容の要旨
Figure 2 Be certain to avoid interference with gas and electric supply to cooktop. Shelving and drawer depths are dependent upon cooktop depth and setback. REMOTE REMOTE INTEGRAL w/ CVT314 w/ CVT7 A 10-3/8" 8-1/16" 12" B 11" 11" 10" Page 4
ページ6に含まれる内容の要旨
FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 Figure 4 INTEGRAL BLOWER REMOTE BLOWER Remote Blower Duct Attach- ment Box CVT314 VTN600CVA Wall Cap WC8 12" Min. Ground ROOF MOUNT INSTALLATION THROUGH WALL INSTALLATION Figure 5 Figure 6 INTEGRAL BLOWER REMOTE BLOWER Duct Attachment VTN600CVA Remote Blower Box CVT314 10" Collar BLOWER ROTATED 90° FOR SIDE CONNECTION THROUGH WALL INSTALLATION THROUGH WALL DUCT INSTALLATION Page 5
ページ7に含まれる内容の要旨
Page 6
ページ8に含まれる内容の要旨
TABLE 2. DUCT WORK INSTALLATION GUIDELINES Keep duct runs as short and straight as possible. Use only duct work constructed of materials that are acceptable by the applicable codes. All duct should Duct fittings (elbows and transitions) reduce air be 26 gauge or heavier to minimize flex due to air flow. flow efficiency. If the VTR1000Q is used, then a 10" diam. round Back to back elbows and "S" turns significantly duct to match the inlet ring is required or a transition reduces air
ページ9に含まれる内容の要旨
CD OD 1/8" BT SB TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Cooktop CWCDOWOD SB BT, Max++ Model No. Cutout Cutout Overall Overall Minimum Backsplash Width Depth Width Depth Set Back Thickness 30” Cooktops: Installed with UCV30 SGS304* 28-15/16 22-1/4 31 23-3/4 1-1/2 3/4 SGSX304* 28-15/16 22-1/4 31 23-3/4 1-1/2 3/4 CET304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 CEP304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 CEM304 28-3/4 22-1/8 31 23-7/8 2-1/2 0 36”Cooktops: Installed with UC
ページ10に含まれる内容の要旨
CD 1/8" OD BT SB B. INSTALLATION WITH ANOTHER BRAND OF COOKTOP (Figure 8) The installer will need to have the cooktop installation 2. Calculate the cutout depth, CD: instructions available to complete the installation. All Determine the cooktop overhang (CO) cooktop dimensions should be verified through measure- CO = (COD-CCD)/2 (Assumes front and rear ment prior to cutting the countertop: cooktop overhangs are equal) Calculate the cutout CCW = Cooktop Cutout Width depth, (CD): CCD = Cooktop C
ページ11に含まれる内容の要旨
STEP 3 PREPARE DUCT CUTOUTS IN CABINET A. Refer to Figure 9. Drop a plumb-line from Point "P" C. Temporarily set intake and cooktop in place and at the center of the rear countertop cutout. attach integral blower (or duct transition fitting if a Mark this point on the bottom of the cabinet. Draw remote blower is installed). Refer to steps 6 and 7. Line AA through this point and parallel to the front Verify that the duct cutouts as marked will match of the cabinet. Through the same point draw Lin
ページ12に含まれる内容の要旨
STEP 4 STEP 6 INSTALL DUCTWORK MOUNT VENT & COOKTOP (REMOTE BLOWER - if used) A. Remove grease filters and any packing materials from inside the intake. A. Install the ductwork and remote blower (if used) in accordance with the ductwork routing plan devel- B. Set the vent intake into rear of countertop opening. oped in Step 1. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging B. Make sure that the installation complies with all from t
ページ13に含まれる内容の要旨
Figure 10 STEP 7 MOUNT INTEGRAL BLOWER OR Remote Blower Transition MOUNT INTEGRAL BLOWER OR Remote Blower Transition Integral Blower VTN600CVA Only A. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet. B. On each side of blower housing there is a flanged edge. When placing the housing onto the intake, these flanges need to be positioned in line with intake flanges. C. Place the support bars over the screw
ページ14に含まれる内容の要旨
STEP 8 Figure 12 VERIFY INSTALLATION, Snorkel Up/ Down button OPERATION & COOKTOP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the Blower Controls lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter instal- lation. Plug the vent power cord into a proper electrical recep- tacle and ensure that the circuit is energized. E. Raise and lower the ven
ページ15に含まれる内容の要旨
NOTES
ページ16に含まれる内容の要旨
5551 McFadden Avenue, Huntington Beach CA, 92649 800-735-4328 BSH Home Appliances Corp. Litho in U.S.A. 10/02 5060004249 (8209)