Résumé du contenu de la page N° 1
F300E
Electronic Air Cleaner
PRODUCT DATA
FEATURES
• Available in four sizes to fit most ducts; adapts to
airflow from either side.
3
• Capacity varies from 1200 cfm (2040 m /hr) to
3
2000 cfm (3400 m /hr), depending on size.
• Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of
cell dirt loading conditions.
• Pressure drop is approximately equal to that of a
regular fiberglass filter.
• Optional W8600F Air Cleaner Monitor indicates air
cleaner perfor
Résumé du contenu de la page N° 2
F300E ELECTRONIC AIR CLEANER Fractional Efficiency: SPECIFICATIONS 70% efficient on 0.3 micron particles at 500 fpm. 90% efficient on 1.0 micron particles at 500 fpm. IMPORTANT 99% efficient on 10.0 micron particles at 500 fpm. The specifications given in this publication do not include normal manufacturing tolerances. Temperature Ratings: Therefore, this unit may not exactly match the listed Operating Ambient: 40° to 125°F (4° to 52°C). specifications. This product is tested and calibrated Temp
Résumé du contenu de la page N° 3
F300E ELECTRONIC AIR CLEANER AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES. .25 [62.2] 16 x 20 in. [406 x 508 mm] .20 [49.7] 20 x 25 in. 16 x 25 in. .15 [508 x 635 mm] [406 x 635 mm] [37.3] 20 x 20 in. [508 x 508 mm] 10 [24.9] .05 [12.4] 2 3 0 100 20 x 25 in. 1 90 (508 x 635 mm) 80 20 x 20 in. (508 x 508 mm) 70 16 x 25 in. 16 x 20 in. (406 x 635 mm) (406 x 508 mm) 60 4 50 400 500 1100 1200 1400 1700 2000 600 700 800 900 1000 1300 1500 1600 1800 1900 [680] [850] [1870] [2040]
Résumé du contenu de la page N° 4
F300E ELECTRONIC AIR CLEANER 3 6 8 (162) SYSTEM DIM. E (SEE TABLE) DIM. B DIM. A (SEE TABLE) (SEE TABLE) 7 8 5 3 (22) DIM. C (SEE TABLE) 6 8 4 (16) (172) DIM. D (SEE TABLE) 2-1/2 (63) DIM. A DIM. B DIM. C DIM. D DIM. E F300 IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM 16 X 25 406 X 635 14 7/16 367 16 3/16 411 23 1/4 591 25 626 2 3/4 70 16 X 20 406 X 508 14 7/16 367 16 3/16 411 18 1/4 457 20 509 2 3/4 70 20 X 25 508 X 635 18 7/16 468 20 3/16 513 23 1/4 591 25 626 2 3/4 70 20 X 20 508 X 508 18 7/16 4
Résumé du contenu de la page N° 5
F300E ELECTRONIC AIR CLEANER 1. Mount it as far as possible upstream from the air Optional W8600A AIRWATCH™ Indicator cleaner. The W8600A can be mounted next to the thermostat or in 2. Install a standard disposable furnace filter between the any other location in the living area of the home where the humidifier and the air cleaner to trap water droplets display can be conveniently observed. No wiring is and hard water salts. necessary. 3. Frequently clean the air cleaner to prevent a hard water
Résumé du contenu de la page N° 6
F300E ELECTRONIC AIR CLEANER A B D C E F G M14732A Fig. 3. Mounting positions with variety of furnace installations. Turning Vanes Determine Duct Design Requirements If the air cleaner is installed close to an elbow or angle The air cleaner is adaptable to all new or existing forced air fitting, install turning vanes inside the angle to distribute heating, cooling and ventilating systems used in residential airflow more evenly across the face of the cell. See Fig. 5. applications. Transitions, t
Résumé du contenu de la page N° 7
F300E ELECTRONIC AIR CLEANER ❑ Place blocks under the cabinet so the unit is firmly INSTALLATION supported and level. The 5/8 in. (16 mm) mounting foot on the cabinet hinge plate provides the minimum clearance required for the access door hinge. When Installing this Product… ❑ Attach the cabinet securely to the furnace. The unit can 1. Read these instructions carefully. Failure to follow them be attached directly, as shown, or a starting collar can could damage the product or cause a hazardous f
Résumé du contenu de la page N° 8
F300E ELECTRONIC AIR CLEANER Table 3. Description of W8600F Function Indicator Panel. Indicators Condition ON EAC is powered and system blower is running. BATTERY Battery that maintains W8600F memory is low and needs to be replaced. TURNING SERVICE EAC prefilter and cells need to be washed . VANES FAULT • Shorting of collector plates. • Continuous ionizer or collector plate arcing. • Power supply failure. • Excessive current. • Major reduction in high voltage. LOCKING • EAC prefilter and cells a
Résumé du contenu de la page N° 9
SYSTEM F300E ELECTRONIC AIR CLEANER Wiring Select Wash Frequency 1. Run a 3-conductor thermostat cable (up to Use the W8600F DIP switches to program the time between 18 gauge) from the W8600F to the terminal strip on SERVICE indications. Be sure to select the setting according the air cleaner. to the conditions of the home. Factors to consider include the duty cycle of the EAC, the number of people and pets, and IMPORTANT activities such as woodworking and other crafts that are being Connect cab
Résumé du contenu de la page N° 10
G 1 Y 2 R 3 B 4 On Battery Service Fault Air Cleaner Monitor F300E ELECTRONIC AIR CLEANER 10. Plug the driver board assembly into the J1 power The W8600A function indicator panel has four liquid crystal supply connector. display (LCD) arrow indicators that point to Battery, Air 11. Replace the power supply box cover. Cleaner, UV Air Treatment, and Humidifier. See Fig. 14. The 12. Connect the three wires from the W8600F to the EAC blinking arrowheads indicate the devices that need service. te
Résumé du contenu de la page N° 11
SYSTEM F300E ELECTRONIC AIR CLEANER NOTE: The UV air treatment system and the humidifier settings are for one year. Theair cleaner settings are selectable according to homeowner activities and needs. DOWNSTREAM 2. Determine the air cleaner filter run time you desireand AIRFLOW set the DIP switches accordingly: CELL KEY a If air cleaner filter is used, select desired filter time CELL SCREW of 3, 6, 9 or 12 months. Follow the settings on the KEY CELL KEY back of the W8600A to set the DIP switches
Résumé du contenu de la page N° 12
F300E ELECTRONIC AIR CLEANER BLACK COLLECTOR TEST RED IONIZER BUTTON RED BLACK CONTACT BOARD 5 P3 BLACK BLACK P4 POWER SUPPLY J4 2 BROWN J3 P2 P1 4 BLACK J1 4 BLUE ORANGE B4 6 RED 5 GRAY R3 1 VIOLET Y2 2 GREEN BLACK G1 BLACK BLACK 1 INTERLOCK SWITCH. W4 W2 W1 W3 2 SHORTING BAR. 3 3 AIRFLOW SWITCH DISABLE JUMPER. 4 OPTIONAL W8600F AIR CLEANER MONITOR. DRIVER AIRFLOW SWITCH BOARD BOARD AND CABLE PROVIDED WITH W8600F. M11975 5 NEON LIGHT. Fig. 18. Internal schematic for electronic a
Résumé du contenu de la page N° 13
F300E ELECTRONIC AIR CLEANER ❑ Alternatively, the electronic air cleaner can be wired with • Outside air, if used, is mixed with return air or heated, as conduit. necessary, before it can reach the air cleaner. 1. Open access door. • Airflow arrows on the electronic cell point downstream. 2. Remove and retain the (2) screws from the front of the • Prefilter is on the upstream side of the cell. power box and the (2) screws from the sides of the • Cell handle faces outward. power box. See Fig. 19.
Résumé du contenu de la page N° 14
F300E ELECTRONIC AIR CLEANER NOTE: To let the heating or air conditioning system Washing the Cell(s) in a Container operate normally while the cell(s) are being washed, simply turn off the air cleaner switch. CAUTION Vacuum the prefilter or brush, or soak it in a tub. Do not Hazardous Chemical. wash the prefilter in the dishwasher or car wash. Can cause personal injury. • Do not splash the detergent solution in eyes. Wear Automatic Dishwasher rubber gloves to avoid prolonged detergent contact wi
Résumé du contenu de la page N° 15
F300E ELECTRONIC AIR CLEANER 5. Rinse the cell(s) and prefilter(s) with a hard spray of COLLECTOR TERMINAL very hot water; rinse the tub clean, then fill the tub with clean hot water and soak for 5 to 15 minutes. Rinse IONIZER TERMINAL until the water draining from the cell(s) and prefilter(s) no longer feels slippery. COLLECTOR TERMINAL 6. Soak cell(s) and prefilter(s) in a final clear water rinse for ten minutes. 7. Wipe the ionizer wires and contact board on the end of the cell using your thu
Résumé du contenu de la page N° 16
F300E ELECTRONIC AIR CLEANER Modification to Reduce Ozone Odor WARNING Electric Shock Hazard. WARNING Can cause personal injury. Only a trained service technician should perform the Electric Shock Hazard. following procedure. Can cause personal injury. Always disconnect power and open the access door 2. This will reduce ozone production about 20 to 25 before opening the power supply cover. percent and reduce efficiency about seven to ten percent, depending on actual airflow delivered by the furn
Résumé du contenu de la page N° 17
F300E ELECTRONIC AIR CLEANER P3 J5 SHUNT P4 IN OZONE REDUCTION POSITION E5 E6 J4 J5 IN NORMAL E4 E3 POSITION E2 E1 J3 P2 P1 M15099 Fig. 25. Move J5 shorting bar to reduce ozone production about 20 to 25 percent. 68-0240-1 17 J1 J5
Résumé du contenu de la page N° 18
F300E ELECTRONIC AIR CLEANER REPLACEMENT PARTS/EXPLODED VIEW Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 20 in. 20 x 25 in. No. Description (406 x 508 mm) (406 x 635 mm) (508 x 508 mm) (508 x 635 mm) 1 Access Door 32004876-004 32004876-004 32004876-003 32004876-003 2 Electronic Cell FC37A1114 (2) FC37A1130 (2) FC37A1049 (2) FC37A1064 (2) 3 Cell Handle 137266 (2) 137266 (2) 137266 (1) 137266 (2) 4 Prefilter 209989 (2) 203371 (2) 203373(2) 203372 (2) 5 Cell Key 136518 (1) 136518 (1) 1
Résumé du contenu de la page N° 19
F300E ELECTRONIC AIR CLEANER 9 8 13 19 16 12 15 14 17 11 6 10 18 7 20 5 4 3 2 1 M14740 Fig. 27. Components of the Electronic Air Cleaner (2-cell model shown). 68-0240-1 19
Résumé du contenu de la page N° 20
F300E ELECTRONIC AIR CLEANER Parts and Accessories Not Illustrated Nominal Return Air Opening 16 x 20 in. 16 x 25 in. 20 x 20 in. 20 x 25 in. Description (406 x 508 mm) (406 x 635 mm) (508 x 508 mm) (508 x 635 mm) Air Cleaner Cabinet Gasket Kit 32002109-001 32002109-001 32002109-001 32002109-001 Ionizer Wires (multiples of 5) 136434BA 136434BA 136434AA 136434AA Mounting Screws 136375 (6) 136375 (6) 136375 (6) 136375 (6) Air Cleaner Monitor W8600F1008 W8600F1008 W8600F1008 W8600F1008 (beige colo