Résumé du contenu de la page N° 1
menu
MCL1801 FAMILY
LCD 18” COLOR MONITOR
User’s Manual
Copyright © 2002 FIMI S.r.l. Saronno - Italy
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
Printed in Italy (Rev. 1.1)
Résumé du contenu de la page N° 2
Copyright © This manual is copyrighted with all rights reserved. Under the copy rights law, this manual may not be copied, in whole or part, without written consent of Philips. Under the law, copying includes translating into another language or format. The monitor described in this manual, has been certifi ed/registered by the safety agencies/regulatory authori- ties as model n° : FCC Notice This equipment has been tested and found to comply with the limits for a class A digital device, purs
Résumé du contenu de la page N° 3
INTRODUCTION The FIMI Medical Grade MCL1801 Medical is a color active matrix, liquid crystal display exclusively designed for medical applications. The monitor can be used for general medical viewing requiring high level color image quality, as well as in the Control Stations of Patient Monitoring, with a resolution of 1280 x 1024, and can accept an analogue signal input as well as a digital input. The product is engineered to meet all stringent medical safety requirements, including UL2601.1
Résumé du contenu de la page N° 4
CONTENTS TECHNICAL INFORMATION.............................................5 DIMENSIONS..........................................................................6 INSTALLATION.....................................................................8 MOUNTING INSTRUCTION..............................................8 CONNECTING INSTRUCTION...........................................9 connecting AC power....................................................10 connecting analog video..........
Résumé du contenu de la page N° 5
TECHNICAL INFORMATION Display Panel 18.1” (460mm) SXGA active matrix monocrome TFT/LCD Supported Grayscale 8-bit Dimensions Panel 410 x 362 x 105 mm. (width x height x depth.) Weight 7,7 Kg ( panel ), 3,7 Kg ( pedestal ) Active display area 359,0 x 287,2 mm ( width x height ) Response Time 40 mS ( 10% to 90% rising + 90% to 10% falling ) Viewing Angle ± 85° typ. horizontal or vertical ( contrast ratio ≥ 15 ) Contrast Ratio 400 : 1 typ. 2 White luminance 200 cd/m Pixel Pitch 0,280
Résumé du contenu de la page N° 6
DIMENSIONS 410 360 197.78 306.02 MCL1801 6 288.2 362 21.3 17.6 22.2 1.5 82 48.7 147.58
Résumé du contenu de la page N° 7
DIMENSIONS 205 205 100 117 MCL1801 7 71 181 181 100 29 117
Résumé du contenu de la page N° 8
INSTALLATION Before unpacking the monitor , prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area that is relatively free of glare from sunlight or other sources of bright light. The monitor is cooled by two internal fans. For best performance, do not block the cooling vents. NOTE: before istalling this monitor, please refer to the user’s guides of your computer and video adapter to make sure if these equipments require any change of setting
Résumé du contenu de la page N° 9
O O MOUNTING INSTRUCTION PEDESTAL STANDARD (OPTIONAL) I fi g. 9a The pedestal must be fi xed at monitor with N° 6 screws M3x10 (included into the BOX) as shown in fi gure 9a. ARM VESA PLATE I fi g. 9b An arm with VESA (100x100) interface must be fi xed at monitor with N° 4 screws M4x10 as shown in fi gure 9b. MCL1801 9
Résumé du contenu de la page N° 10
O O CONNECTING INSTRUCTION CONNECTING AC POWER Plug the receptacle and of the cord set into the AC power adapter, then plug the power connector of the adapter into the power port on the monitor. This power port is located on the back of the monitor (see fi g. 10a). MAINS SWITCH I fi g.10a The power cord set can be fi xed to cabinet with proper cable clamp and screw (see fi g. 10b) I fi g 10b Insert the plug end of the power cord into a grounded wall outlet. For added protection, use a surge protec
Résumé du contenu de la page N° 11
G R B G R B O O CONNECTING ANALOG VIDEO (SXGA) With the power the computer and the monitor turned off, connect the supplied video cable from the monitor to the computer’s video port (see fi g. 11a) I fi g. 11a Make sure the video cable connector is securely connected to the video port on your computer. Turn the monitor on fi rst, and then turn on the computer. CONNECTING DIGITAL VIDEO (DVI) With the power the computer and the monitor turned off, connect the supplied video cable from the monitor t
Résumé du contenu de la page N° 12
G R B O CONNECTING TOUCHSCREEN (OPTIONAL) If your monitor has this optional feature, connect the monitor’s RJ11-4 serial port to the computer’s 9-pin RS-232 serial port using the proper cable (see fi g. 12a) I fi g. 12a NOTE: Follow the instructions included on the enclosed CD for installing the Touchscreen drivers on your system. Following driver software installation, calibrate your Touchscreen to the system following the procedure described on the enclosed CD. MCL1801 12
Résumé du contenu de la page N° 13
INPUT INSTRUCTION fi g.13a RS232 DVI-INPUT VIDEO-INPUT AC INLET or XVGA MAINS SOCKET TOUCHSCREEN AC INLET (Meet IEC 320/CEE 22 STANDARD) 110/220Vdc RS232 / TOUCHSCREEN Connector (RJ11-4) Pin 1 : RS232 Rx Pin 2 : RS232 Tx Pin 3 : ENABLE (Only with touch screen) Pin 4 : GND Note: When the option touchscreen is used, the RS232 monitor control is not available. DVI INPUT Connector (Microcross™ DVI-D female connector) Pin 1 : D2_RX - (T.M.D.S.) Pin 13 : N.C. Pin 2 :
Résumé du contenu de la page N° 14
menu CONTROL PANEL DESCRIPTION On the front bottom side part of the unit the following controls are placed: - BRIGHTNESS ADJ- - BRIGHTNESS ADJ+ - MENU SELECT - / BRIGHTNESS Recall to 200 Cd/m² - MENU SELECT + - ENTER (Store/Source-Select) Light sensor LED GREEN= 200 cd/m² / Power-on RED < 200 cd/m² ORANGE= Stand-by fi g. 14a Power Switch menu Brightness Adjust - Enter Brightness Adjust + Menu select + Menu select - MCL1801 14
Résumé du contenu de la page N° 15
(OSD) ON SCREEN DISPLAY MENU STRUCTURE MAIN MENU │ ├───── INFORMATION │ ├───── CODE VERSION │ └───── EXIT │ ├───── IMAGE ADJUST │ ├───── HORIZONTAL POSITION │ ├───── VERTICAL POSITION │ ├───── SCALE / CENTER ─────┐ │ │ ├───── FULL SCREEN │ │ ├───── MAINTAIN ASPECT RATIO │ │ └───── CENTER │ ├───── IMAGE ENHANCEMENT │ │ ├───── ABC SELECTION │ │ │ ├─────────────ABC OFF │ │ │ ├─────────────ABC REDUCED │ │ │ └─────────────ABC FULL │ │ ├───── TRANSFER FUNCTION │
Résumé du contenu de la page N° 16
OSD KEY FUNCTIONS Function Key Description Enter N It activates the OSD MAIN MENU if this is not active, otherwise selects and executes a desired OSD Special Function. Adjust - Menu - When main menu or sub-menu is active, it allows to move or scroll to the previous (upper) item or decrement the magnitude of the parameter. Adjust + Menu + When main menu or sub-menu is active, it allows to move or scroll to the previous (down) item or increment the magnitud
Résumé du contenu de la page N° 17
6.2.0 Information 1) Press Enter button when the Information is highlighted on Main menu. The Information window appears. MCL1801 Model Ver CO.62-DO.62 Firmware Release h00002 Operating Hours c1B Video timing number 3) To press Enter buttton to return to Main Menu. Information FIMI-Philips MCL1801 Ver CO.62-DO.62 h00002 c1B Exit 6.3.0 Image Adjust 1) Press Enter button when the Image Adjust is highlighted on Main Menu. The Image Adjust window appears. Image Adjust Ho
Résumé du contenu de la page N° 18
6.3.2 Vertical Position 1) Press Enter button when the Vertical Position is highlighted on Image Adjust. The Vertical Position bar appears. Image Adjust Horizontal Position Vertical position Scale / Center Image Enhancement Advanced Exit 2) Press Adjust + or Adjust - button to move the image to the up or down 3) When the position is adjusted, press the Enter button to return to Image Adjust window 4) To select Exit and press again Enter button to return to Main Menu or select Scale
Résumé du contenu de la page N° 19
6.3.5 ABC Selection 1) Press Enter button when the ABC Selection is highlighted on Image Enhancement The ABC Selection window appears. ABC Selection ABC Off ABC Reduced ABC Full 2) Press the Adjust + or Adjust - button until the desired item is highlighted. - ABC off Manual back light control regulated by panel button from 80 cd/m² to 200 cd/m² - ABC full Automatic control of back light, the back light is function of ambient light and follow a semilogaritmic courve from 80
Résumé du contenu de la page N° 20
Advanced Phase Adjust Clock Adjust Service Auto-Setup Options Auto-(Phase/Position) Auto-(Clock/Position) Auto-Level Restore Factory Presets Exit 2) Press the Menu + or Menu - button until the desired source is highlighted. 6.3.8 Phase Adjust 1) Press Enter button when the Phase Adjust is highlighted on Advanced. The Phase Adjust bar appears. 2) Press Adjust + or Adjust - button to adjust the quality image Note: It is necessary to use video pattern dedicated to obtain the best result