Résumé du contenu de la page N° 1
NetworkAIR™ 1000
Portable
Air Conditioner
AP7003
AP7004
User’s Manual
®
Résumé du contenu de la page N° 2
Important Safety Information Warning Read these instructions carefully before using this air conditioner. This air conditioner is designed for indoor use only. The temperature range for the cooling mode is 61° F to 86° F. To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. Do not open the cabinet while the unit is connected a power source. Dangerous voltage is present. Have repairs performed by certified HVAC technicians. Never use or store g
Résumé du contenu de la page N° 3
Contents General Information . . . . . . . . . . . . . . . . . . . . . . . .1 About NetworkAIR 1000 1 Inventory 1 Front View 2 Back View 2 Control Panel 3 LCD Indicators 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Warnings 5 Set up the unit 5 Check components 6 Power the unit 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Power 7 Cooling 7 Dehumidify 7 Fan 7 Louver 7 Timer 8 Installing the Exhaust Ki
Résumé du contenu de la page N° 4
Contents continued Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . .17 Try this first 17 If problems persist 19 Warranty Information . . . . . . . . . . . . . . . . . . . . .20 Limited warranty 20 Warranty limitations 20 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 ii
Résumé du contenu de la page N° 5
General Information About APC’s NetworkAIR 1000 is a portable, compact, air- NetworkAIR conditioner designed for spot-cooling, emergency-cooling, and 1000 after-hours cooling of server closets, data centers, conference rooms, home offices, or rooms housing heat-sensitive equipment. The NetworkAIR 1000 provides 7,200 BTU (7,500 BTU for AP7004) of cooling power. It automatically adjusts room temperature, and reduces moisture while filtering the air. Additional features of NetworkAIR 1000
Résumé du contenu de la page N° 6
General Information continued Front View Control Panel Horizontal Air Flow Guides Handle Vertical Swing Louver Water Tank Power Cord Caster & Plug Back View Washable Air Filter Drain Valve Exhaust Vent 2
Résumé du contenu de la page N° 7
General Information continued Control Panel Power Turns the unit on and off. Sets the desired operating mode: Mode fan, cooling, or dehumidifying. Sets desired fan speed: high, Fan Speed medium or low. Louver Directs the air distribution. Sets the desired temperature (61°– Temperature 86°F). Programs the timer for unattended Timer shutoff (up to 18 hours for AP7003, 24 hours for AP7004). Indicates that the compressor is Compressor running when in cooling or indicator dehumidifying mode
Résumé du contenu de la page N° 8
General Information continued LCD Indicators Temperature Fan Mode Cooling Mode Dehumidify Mode Louver On Timer On/Off Timer Setting Fan Speed Set Temperature Note: Temperature is shown in Celsius on the AP7004. 4
Résumé du contenu de la page N° 9
Installation Warnings Use the unit on a flat surface where the air outlets are unobstructed. Do not place the unit less that 20 inches (50 cm) away from any wall or obstacle. Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a green house. 20 in (50 cm) 20 in (50 cm) Set up the unit 1. Unpack the unit and the accessory kit. Slip the bands off the unit—do not cut the bands. 2. Inspect the unit and the accessories for dama
Résumé du contenu de la page N° 10
Installation continued Check 1. Check that the condensate tank on the side of the unit is in components place and is properly seated. If the tank is not installed properly, the unit will not operate. 2. Open the air filter cover on the left side of the unit and check that the air filter is clean. Power the unit 1. Plug the unit into a wall outlet. Wait two seconds for the unit to beep. Note: The unit has a 6-foot power cord. Do not plug the unit into an extension cord. 2. Turn the unit o
Résumé du contenu de la page N° 11
Operation Power Turn the unit on or off by pressing the Power button. Cooling To select the Cooling mode, press the Mode button until the cooling mode indicator appears in the LCD window. Set the fan speed by pressing the Fan Speed button. The fan speed indicator in the LCD window will display what speed has been selected - high, medium or low. Set the temperature by pressing the Temperature button up or down arrow . The LCD window will display the current temperature selected.
Résumé du contenu de la page N° 12
Operation continued Timer Your portable air conditioner has a timer feature that allows the unit to shut off or turn on automatically in a preset number of hours. 1. Set Timer On mode a. Make sure mode (cool, dehumidify or fan), tempera- ture, and fan options are on the desired setting. b. Turn the unit off. c. Press the Timer button and the LCD window will dis- play Timer On. d. Press the time up or down buttons to increase or decrease the amount of time. The timer will automat- ically
Résumé du contenu de la page N° 13
Installing the Exhaust Kit Installing into For this installation you will need the following: ceiling plenum The ceiling adapter The holder flange The exhaust duct The base flange Note: There should be about 12 to 15 inches of open space above the ceiling adapter opening so that exhaust air is not blocked 1. The exhaust duct is 8.5 feet long. Insert about 6 inches of one end of the exhaust duct into the round hole in the ceil- ing adapter. 2. Extend the 6 inches of the exhaust duct
Résumé du contenu de la page N° 14
Installing the Exhaust Kit continued Installing into 5. For permanent installation, cut five inches off the ceiling ceiling plenum, tile so that the tile will lay flat in the grid. continued 6. For temporary installations, slide the ceiling tile tight against the ceiling adapter. 7. Screw the other end of the exhaust duct into the base flange 8. Slide the base flange onto the exhaust vent on the back of the unit 10
Résumé du contenu de la page N° 15
Drainage Methods of The NetworkAIR 1000 has two methods of disposing of the Draining condensation. The first is a condensate tank that can be manually emptied. The second method is to attach a drain hose to the unit so the water will run to a floor drain. Condensate The condensation will drain into the condensate tank when the Tank unit is in the Cooling or Dehumidifying mode. The Tank Full indicator will flash on the control panel and the unit will beep several times when the tank is full
Résumé du contenu de la page N° 16
Drainage continued Emptying the To manually drain the tank: tank 1. Turn off the unit. 2. Using the handle, slowly remove the tank from the side of the unit. 3. Pour out any condensation accumulated in the tank. 4. Wipe up any condensation that may have drained off the evaporator coil. 5. Replace the tank in the unit. 6. Turn the power on and make sure tank is properly seated (the unit will beep and Tank Full indicator will flash if tank is not properly positioned). 7. Allow the fan to run
Résumé du contenu de la page N° 17
Drainage continued The drainage 1. Slide out the drain valve from the left side of the unit. tube 2. Attach the drainage tube to the drain valve. 3. Route the tubing downward so that condensate flows prop- erly into a floor drain or condensate line below the unit. Note: Condensation will drip through the drain valve if it is open. Make sure there is a hose attached to the it and a floor drain or condensate line below the unit whenever the drain valve is open. 13
Résumé du contenu de la page N° 18
Maintaining the Unit Clean the air APC recommends cleaning your air filter at least after every filter two weeks of use. Keeping your air filter clean will maximize the performance and life of this product. 1. Turn off the unit and unplug it from its electrical outlet. 2. Open the air filter on the left side of the unit. 3. Remove the air filter from the cover. 4. Wash air filter with a neutral detergent and warm water and let it air dry. 5. Reinsert the filter into the cover. Clean the Turn
Résumé du contenu de la page N° 19
Maintaining the Unit continued Clean the 1. Turn off the unit and unplug it from its electrical outlet condensate 2. Using the handle, slowly remove the condensate tank from tank regularly the side of the unit. 3. Pour out any condensation accumulated in the tank. 4. Clean the inside of the tank with a solution of warm water and mild detergent to avoid the growth of mold and mil- dew. 5. Replace the tank in the unit. 6. Turn the power on and make sure tank is properly seated (unit will be
Résumé du contenu de la page N° 20
Maintaining the Unit continued Storing the Unit The following precautions must be taken when storing the unit for extended periods of time: 1. Turn off unit. 2. Clean the air filter and allow to air dry before replacing in unit. 3. Empty the condensate tank. 4. Remove the stopper from the water drain pipe and drain until empty. Reinsert the water drain pipe into the unit. Stopper Water Drain Pipe 5. Replace the tank. 6. Turn the unit on and allow the fan to run three minutes after emptying