Résumé du contenu de la page N° 1
Intel® Server Board SE7320VP2
User Guide
Order Number: C71354-002
Résumé du contenu de la page N° 2
Disclaimer ® Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a par
Résumé du contenu de la page N° 3
Preface About this Manual ® Thank you for purchasing and using the Intel Server Board SE7320VP2. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and reparing this server board. This document provides a brief overview of the features of the board/chassis, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel Server Board SE7320VP2. For the lat
Résumé du contenu de la page N° 4
Preface Additional Information and Software If you need more information about this product or information about the accessories that can be used with this server board, use the following resources. These files are available at http://support.intel.com/support/motherboards/server/SE7320VP2 Unless otherwise indicated in the table below, once on this Web page, type the document or software name in the search field at the left side of the screen and select the option to search “This Product
Résumé du contenu de la page N° 5
Preface Safety Information WARNING Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory
Résumé du contenu de la page N° 6
Preface Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunication
Résumé du contenu de la page N° 7
Preface Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/. SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps: 1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power b
Résumé du contenu de la page N° 8
Preface 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。参见 Resource CD(资源光盘) 和/或 http://support.intel.com/support/motherboards/server/ 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。 Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site
Résumé du contenu de la page N° 9
Preface Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y/o en http://support.intel.com/support/motherboards/server/. INSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las siguientes instrucciones: 1. Apague todos los dispositivos periféri
Résumé du contenu de la page N° 10
Preface x
Résumé du contenu de la page N° 11
Contents Contents 1 Server Board Features................................................................................. 15 Connector and Header Locations .........................................................................................17 Configuration Jumpers..........................................................................................................18 Back Panel Connectors.............................................................................................
Résumé du contenu de la page N° 12
Contents Characters Are Distorted or Incorrect...........................................................................43 System Cooling Fans Do Not Rotate Properly.............................................................44 Diskette Drive Activity Light Does Not Light.................................................................44 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light ...............................45 Cannot Connect to a Server.................................
Résumé du contenu de la page N° 13
Contents Tables Table 1. Server Board Features ..................................................................................16 Table 2. Recovery Jumper [J1H2, J1H3, J1H5] ..........................................................18 Table 3. Serial Port Configuration Jumper [J8A3] .......................................................19 Table 4. BIOS Select Jumper [J1A4]...........................................................................20 Table 5. NIC LEDs.....................
Résumé du contenu de la page N° 14
Contents xiv
Résumé du contenu de la page N° 15
1 Server Board Features ® This chapter briefly describes the main features of Intel Server Board SE7320VP2. This chapter provides a photograph of the product, a list of the server board features, and diagrams showing the location of important components and connections on the server board. The Server Board SE7320VP2 is shown in the following picture. ® Figure 1. Intel Server Board SE7320VP2 Intel® Server Board SE7320VP2 User Guide 15
Résumé du contenu de la page N° 16
Server Board Features Table 1 summarizes the major features of the server board. Table 1. Server Board Features Feature Description Processors Support for up to two Intel® Xeon™ processors with an 800 MT/s MHz front side bus and frequencies starting at 2.8 GHz. Memory Six DIMM slots supporting DDR266MHz or DDR333MHz memory Memory mirroring and memory sparing options Chipset Intel® E7320 chipset, including: Intel E7320 MCH Intel 6300ESB ICH I/O Control External connections: Stack
Résumé du contenu de la page N° 17
Server Board Features Connector and Header Locations A B C D E CC F BB AA Z G Y H X W V U T S R Q P N L J I O M K TP00941 A Serial Port A header K Processor 2 fan header U Configuration jumpers B Battery L +12V processor power V SATA 1 connector connector C Full-height PCI slot M Fan board connector W SATA 0 connector D Low-profile PCI slot N Floppy connector Z Power supply connector E Back panel I/O ports O PCI fan connecors (two) Y OEM RMC connector F Serial port selection jumper P I
Résumé du contenu de la page N° 18
Server Board Features Configuration Jumpers Recovery Jumpers J1H2, J1H3, J1H5 J1H2 Pass Clr 3 Protect 2 Erase J1H3 Rcvr Boot Recovery Boot 2 Normal Boot 3 J1H5 CMOS Clr 3 BMC Control 2 Force Erase TP00942 Figure 3. Recovery Jumper Location Table 2. Recovery Jumper [J1H2, J1H3, J1H5] Jumper Name Pins What happens at system reset… J1H2: Password 1-2 If these pins are jumpered, administrator and user passwords will be cleared on the Clear next reset. These pins should not be jumpered
Résumé du contenu de la page N° 19
Server Board Features Serial Port Configuration Jumper J8A3 34 1-3: DCD to DTR (Default) 2-4: DSR to DTR 2 TP00944 Figure 4. Serial Port Configuration Jumper Location Table 3. Serial Port Configuration Jumper [J8A3] Pins What happens at system reset… 1-3 Serial port is configured for DCD to DTR (default) 2-4 Serial port is configured for DSR to DTR. 19
Résumé du contenu de la page N° 20
Server Board Features BIOS Select Jumper J1A4 BIOS Select 1-2: Normal Operation (Default) 3 2-3: Force to Lower Bank 3 TP00949 Figure 5. BIOS Select Jumper Location Table 4. BIOS Select Jumper [J1A4] Pins What happens at system reset… 1-2 System is configured for normal operation 2-3 Force BIOS to lower bank 20