Résumé du contenu de la page N° 1
WHYNTER PORTABLE AIR CONDITIONER
MODEL# : ARC-13PG
Instruction Manual
Thank you for your purchase of this WHYNTER product. Please read this Instruction Manual carefully before
using product to ensure proper use. Keep this manual in a safe place for future reference.
Résumé du contenu de la page N° 2
2 Thank you for choosing the Whynter portable air conditioner. Please follow the instructions given in this booklet to obtain the very best performance from your portable air conditioner and take full advantage of the many advance features that your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference. DISPOSAL
Résumé du contenu de la page N° 3
3 PARTS OVERVIEW 1. Exhaust hose 2. Rectangle Connector 3. Round Connector 4. Round Cover 5. Window Suction Cup 6. User Manual 7. Remote Control 8. Window Slide Bars For this portable air conditioner to operate correctly, the hot air from the back of the unit must be vented to the outside. Please follow the instructions below for window kit installation. 1. Extend the exhaust hose (Part 1) at least 6” and insert it to the outdoor exhaust outlet at back of the air conditioner. 2
Résumé du contenu de la page N° 4
4 UNIT OVERVIEW 1. Control panel 2. Air outlet grille 3. Air filter grille 4. Drain plug 5. Outdoor air inlet 6. Outdoor exhaust 7. Handle
Résumé du contenu de la page N° 5
5 Incorrect Assembly: Correct Assembly: Ensure curtains or other objects are not obstructing the air inlet filters. (Fig 3) Do not bend or crush the exhaust hose while in use. (Fig.3)
Résumé du contenu de la page N° 6
6 SAFETY PRECAUTIONS Ensure curtains or other objects are not obstructing the air inlet filters. Do not bend or crush the exhaust hose while in use. Transport the unit in an upright position only, or leave it in an upright position for at least 2 hours before first use. Always place the unit on even and hard and level surface. The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the po
Résumé du contenu de la page N° 7
7 INSTALLATION When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in fan-only mode, no exhaust is required. Exhaust hose Installation The exhaust hose must be installed onto the unit. 1. Pull out about 6” of one end of the exhaust hose. 2. Screw the exhaust connector on the exhaust hose in a clockwise motion. 3. Snap the exhaust connector in place in the back of the unit
Résumé du contenu de la page N° 8
8 Window Installation 1. Make sure the exhaust hose is properly installed onto the portable air conditioner. 2. Open window or sliding door for approximately 5” (130 mm) 3. Adjust the length of the window kit to the same length and width of the opening of the window or the sliding door. Cut the window piece if necessary to fit the length of your window or sliding door. 4. Place the window kit on your window or sliding door, with the exhaust hole as near to the portable air conditioner
Résumé du contenu de la page N° 9
9 CONTROL PANEL Indicator Light: Standby mode LED (red). 1: Power – Turns the unit on and off. 2: Mode Control – Controls the 4 function modes: 3: Fan Speed Control – Controls the 3 fan speeds: Cooling, Automatic, Fan only & Dehumidification. High, Medium, Low. 4: Plus – Increases set temperature or timer hours. 5: Minus – Decreases set temperature or timer 6: Timer – Turns the timer function on and off. hours. S1: Timer indicator S2: Temperature indicator S3: Delayed function
Résumé du contenu de la page N° 10
10 OPERATIONS SWITCHING ON THE AIR CONDITIONER The portable air conditioner can be switched on by the remote control or by pressing the Power button on the control panel. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet. NOTE: Other appliances in
Résumé du contenu de la page N° 11
11 REMOTE CONTROL BUTTONS DISPLAY B1: POWER – Turns the unit on and off. 1: Set temperature B2: MODE – Controls the 4 function 2: Delay time setting modes: Cooling, Automatic, Fan only & Dehumidification. B3: TUBRO – Turns the unit on Cooling 3. Delayed switch OFF mode, lowest temperature (61°F) and maximum fan speed. B4: Plus – Increases set temperature or 4. Remote control signal timer hours. strength B5: Minus – Decreases set temperature 5. Auto fan speed mode or timer
Résumé du contenu de la page N° 12
12 SWITCHING ON/OFF THE AIR CONDITIONER The appliance can be switched ON or OFF by pressing the Power button (1) on the control panel or the Power button (B1) on the remote control. FAN ONLY MODE In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button (B2 on remote control or 2 on control panel) until fan only symbol ( )appears on the displays. In this function mode, the temperature cannot be set.
Résumé du contenu de la page N° 13
13 AUTOMATIC MODE In this mode, the air conditioner is set to run at the optimum comfort temperature. When the Automatic (comfort) mode is selected, the cooling function stops when the temperature is below 73°F. The cooling function and low fan speed starts when temperature is between 73°F - 77°F Cooling function and medium fan speed starts when temperature is between 77°F - 81°F. Cooling function and high fan speed starts when temperature is above 81°F. To activate this function mode
Résumé du contenu de la page N° 14
14 SETTING SWITCH OFF TIMER FROM CONTROL PANEL With the air conditioner operating in any function mode, press the Timer button (6 on control panel) and set the desired time delay OFF hours (from 1 to 12 hours) by pressing the + and – buttons. Once the delayed switch off timer is set, press the Timer button (6 on control panel) to confirm the setting. The symbol and the delay countdown timer will appear on the control panel display. When the delay time set has elapsed, the air condi
Résumé du contenu de la page N° 15
15 TRANSPORTATION The air conditioner is equipped with wheels and handles for easy portability. Before moving the air conditioner, proceed as follows: Switch off the air conditioner and disconnect the plug from the power outlet Drain water by removing the drain plug. Always transport the air conditioner in an upright position only. MAINTENANCE CLEANING THE AIR FILTER To ensure the air intake is filtered properly and to
Résumé du contenu de la page N° 16
16 DRAINING THE AIR CONDITIONER ALWAYS switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner. Position a flat container or dish under the drain hole. Do not allow the water to drip continuously into the container, as it might easily overflow. Remove the drain stopper from the drain hole. The condensed water will drain out automatically. When the container is almost full, insert the drain stopper back to the unit.
Résumé du contenu de la page N° 17
17 TROUBLESHOOTING Problem Possible Causes Solutions Power failure / outage. Restore the power supply. The portable air conditioner does not turn on The automatic switch, line fuse, or breaker has Flip the switch / change the fuse / turn the breaker back on. Also note been tripped. that you may have too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit. Move the unit onto another circuit with the correct voltage.
Résumé du contenu de la page N° 18
18 The unit is set to low fan speed. Set the unit to a higher fan speed. The unit has worked for a long Windows or doors are open. Close all windows and doors. time, but the room is not cold enough There are too many people in the room. You may need additional cooling or another air conditioner. There is direct sunshine into the room. Close curtains or blinds and try to minimize the amount of direct sunlight into the room. The room is a kitchen or with many heat- You may need
Résumé du contenu de la page N° 19
19 TECHNICAL DATA Cooling capacity 13,000 BTU Recommended room size* 420 sq. ft. E.E.R. – Energy efficiency rate 14.3 Power supply 115v/ 60Hz Maximum power input 910 Watts Maximum input 8.20 Amps Dehumidifying capacity 43 Pts / Day 61°F to 86°F / 16°C to 32°C Thermostat Refrigerant R-410A Compressor Rotary Air flow (max) 380 m3/ Hour Fan speeds 3 (H, M, L) Exhaust hose length 5 ft. Unit Dimensions 18” W x 15.5” D x 30” H Unit Weight 66 lbs
Résumé du contenu de la page N° 20
20 ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR This WHYNTER portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your WHYNTER portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months