Résumé du contenu de la page N° 1
H8S/2237 Series
TQFP-100G
User System Interface Cable
(HS2237ECN61H)
for E6000 Emulator
User’s Manual
HS2237ECN61HE(C)
Résumé du contenu de la page N° 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Résumé du contenu de la page N° 3
Preface Thank you for purchasing this user system interface cable (HS2237ECN61H) for the Renesas’s original microcomputer H8S/2237 series. The HS2237ECN61H is a user system interface cable that connects an H8S/2633 series E6000 emulator (HS2633EPI61H; hereinafter referred to as the emulator) to the IC socket for a TQFP-100G package (package code: TFP-100G) for the H8S/2237 series MCU on the user system. i
Résumé du contenu de la page N° 4
Contents Preface .........................................................................................................i Section 1 Configuration...................................................................................1 Section 2 Connection Procedures....................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User Syste
Résumé du contenu de la page N° 5
Section 1 Configuration CAUTION Use an NQPACK100SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-100G package IC socket on the user system. Figure 1 shows the configuration of the HS2237ECN61H user system interface cable for the TFP-100G package. 1
Résumé du contenu de la page N° 6
To emulator station Cable body Screws (M2 x 10 mm) (for fastening cable head) Screws (M2 x 6 mm) Socket cover Cable head IC socket User system Figure 1 HS2237ECN61H User System Interface Cable 2
Résumé du contenu de la page N° 7
Table 1 lists the HS2237ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2237ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP-100G package 4 Socket cover 1 For installing a TFP-100G packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cable head 6 Screws (M2 x 6 mm) 4 For installing a TFP-100G packaged MCU 7 Guide pins (φ 1 mm) 3 For determining the IC socket loc
Résumé du contenu de la page N° 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the
Résumé du contenu de la page N° 9
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow
Résumé du contenu de la page N° 10
2.2.1 Installing IC Socket 1. Confirming the location of IC socket CAUTION After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system. Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. Pin 1 Guide pins 4 projections to apply IC socket epoxy resin adhesive to (NQPACK100SE manufactured by Tokyo Eletech Corporation
Résumé du contenu de la page N° 11
2.2.2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a TFP-100G package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4. 2.2.3 Fastening Cable Head CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque mus
Résumé du contenu de la page N° 12
Fasten the user system interface cable head to the IC socket for a TFP-100G package on the user system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2 x 10 mm) Cable head IC socket Pin 1 (NQPACK100SE m
Résumé du contenu de la page N° 13
2.2.4 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body 9
Résumé du contenu de la page N° 14
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TFP-100G package (NQPACK100SE: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. 15.10 (min.) 11.10 (max.) 0.40 x 24 = 9.60 – 0.05 0.40 – 0.05 0.20 – 0.05 Unit: mm Figure 6 Recommended Dimensions for Mount Pad 10 0.40 – 0
Résumé du contenu de la page N° 15
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Unit: mm Tolerance: –0.5 mm Figure 7 Dimensions for User System Interface Cable Head 11
Résumé du contenu de la page N° 16
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head IC socket (NQPACK100SE User system Unit: mm manufactured by Tolerance: –0.5 mm Tokyo Eletech Corporation) Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12
Résumé du contenu de la page N° 17
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket co
Résumé du contenu de la page N° 18
Screws (M2 x 6 mm) Socket cover MCU Pin 1 IC socket (NQPACK100SE manufactured by Tokyo Eleteck Corporation) User system Figure 9 Installing MCU to User System 14
Résumé du contenu de la page N° 19
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described in the E6000 Series Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins with the MEMORY_FILL command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator conne
Résumé du contenu de la page N° 20
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS2633EPI61H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the cabl