Résumé du contenu de la page N° 1
General-Purpose AC Servo
MODEL
MR-E- A/AG
INSTRUCTION MANUAL
B
Résumé du contenu de la page N° 2
Safety Instructions (Always read these instructions before using the equipment.) Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly. Do not use the servo amplifier and servo motor until you have a full knowledge of the equipment, safety information and instructions. In this Instructi
Résumé du contenu de la page N° 3
1. To prevent electric shock, note the following: WARNING Before wiring or inspection, switch power off and wait for more than 10 minutes. Then, confirm the voltage is safe with voltage tester. Otherwise, you may get an electric shock. Connect the servo amplifier and servo motor to ground. Any person who is involved in wiring and inspection should be fully competent to do the work. Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get
Résumé du contenu de la page N° 4
4. Additional instructions The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric shock, etc. (1) Transportation and installation CAUTION Transport the products correctly according to their weights. Stacking in excess of the specified number of products is not allowed. Do not carry the servo motor by the cables, shaft or encoder. Do not hold the front cover to transport the servo amplifier. The servo amplifier may drop. Install the servo am
Résumé du contenu de la page N° 5
(2) Wiring CAUTION Wire the equipment correctly and securely. Otherwise, the servo motor may misoperate. Do not install a power capacitor, surge absorber or radio noise filter (FR-BIF option) between the servo motor and servo amplifier. Connect the output terminals (U, V, W) correctly. Otherwise, the servo motor will operate improperly. Do not connect AC power directly to the servo motor. Otherwise, a fault may occur. The surge absorbing diode installed on the DC output signal relay must be wir
Résumé du contenu de la page N° 6
(5) Corrective actions CAUTION When it is assumed that a hazardous condition may take place at the occur due to a power failure or a product fault, use a servo motor with electromagnetic brake or an external brake mechanism for the purpose of prevention. Configure the electromagnetic brake circuit so that it is activated not only by the servo amplifier signals but also by an external emergency stop signal (EMG). Contacts must be open when servo-on signal is off, when an Circuit must be alarm (
Résumé du contenu de la page N° 7
About processing of waste When you discard servo amplifier, a battery (primary battery), and other option articles, please follow the law of each country (area). FOR MAXIMUM SAFETY This product is not designed or manufactured to be used in equipment or systems in situations that can affect or endanger human life. When considering this product for operation in special applications such as machinery or systems used in passenger transportation, medical, aerospace, atomic power, electric power,
Résumé du contenu de la page N° 8
COMPLIANCE WITH EC DIRECTIVES 1. WHAT ARE EC DIRECTIVES? The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of safety-guaranteed products. In the EU countries, the machinery directive (effective in January, 1995), EMC directive (effective in January, 1996) and low voltage directive (effective in January, 1997) of the EC directives require that products to be sold should meet their fundamental safety requirements and carry the CE marks
Résumé du contenu de la page N° 9
(5) Grounding (a) To prevent an electric shock, always connect the protective earth (PE) terminals (marked ) of the servo amplifier to the protective earth (PE) of the control box. Connect PE terminal of the control box to the NEUTRAL of a power supply. Be sure to ground the NEUTRAL of a power supply. (b) Do not connect two ground cables to the same protective earth (PE) terminal. Always connect the cables to the terminals one-to-one. PE terminals PE terminals (c) If a leakage current breaker
Résumé du contenu de la page N° 10
CONFORMANCE WITH UL/C-UL STANDARD (1) Servo amplifiers and servo motors used (Acquisition schedule) Use the servo amplifiers and servo motors which comply with the standard model. Servo amplifier :MR-E-10A to MR-E-200A Servo motor :HC-KFE HC-SFE (2) Installation 3 Install a fan of 100CFM (2.8 m /min) air flow 4 in (10.16 cm) above the servo amplifier or provide cooling of at least equivalent capability. (3) Short circuit rating This servo amplifier conforms to the circuit whose peak current i
Résumé du contenu de la page N° 11
MEMO A - 10
Résumé du contenu de la page N° 12
CONTENTS 1. FUNCTIONS AND CONFIGURATION 1- 1 to 1-10 1.1 Introduction.............................................................................................................................................. 1- 1 1.2 Function block diagram .......................................................................................................................... 1- 2 1.3 Servo amplifier standard specifications ....................................................................................
Résumé du contenu de la page N° 13
4. OPERATION 4- 1 to 4- 6 4.1 When switching power on for the first time.......................................................................................... 4- 1 4.2 Startup...................................................................................................................................................... 4- 2 4.2.1 Selection of control mode.................................................................................................................. 4- 2 4.2.2 Position
Résumé du contenu de la page N° 14
7.3 Manual mode 1 (simple manual adjustment)....................................................................................... 7- 7 7.3.1 Operation of manual mode 1 ........................................................................................................... 7- 7 7.3.2 Adjustment by manual mode 1 ....................................................................................................... 7- 7 7.4 Interpolation mode ...................................................
Résumé du contenu de la page N° 15
13.2 Auxiliary equipment ..........................................................................................................................13-21 13.2.1 Recommended wires....................................................................................................................13-21 13.2.2 No-fuse breakers, fuses, magnetic contactors...........................................................................13-23 13.2.3 Power factor improving reactors ..............................
Résumé du contenu de la page N° 16
15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT 15- 1 to 15- 62 15.1. Functions and configuration..............................................................................................................15- 1 15.1.1 Introduction...................................................................................................................................15- 1 15.1.2 Function block diagram ..........................................................................................
Résumé du contenu de la page N° 17
MEMO 6
Résumé du contenu de la page N° 18
1. FUNCTIONS AND CONFIGURATION 1. FUNCTIONS AND CONFIGURATION 1.1 Introduction The Mitsubishi MR-E series general-purpose AC servo is based on the MR-J2-Super series, and has the same high performance and limited functions. It has position control and internal speed control modes. Further, it can perform operation with the control modes changed, e.g. position/internal speed control. Hence, it is applicable to a wide range of fields, precision positioning and smooth speed control of machine tools
Résumé du contenu de la page N° 19
1. FUNCTIONS AND CONFIGURATION 1.2 Function block diagram The function block diagram of this servo is shown below. Regenerative brake option (Note 3) Servo amplifier Servo motor P D C (Note 3) (Note 3) (Note 2) (Note 1) Power DS RA NFB MC U U supply L1 3-phase Regenerative V V Current L2 200 to SM TR detector 230VAC, W W CHARGE L3 1-phase lamp 230VAC Dynamic brake Fan E1 Electro- (MR-E-200A only) magnetic E2 Control brake power supply (Note 3) Regenerative brake Voltage Current Base amplifier Ov
Résumé du contenu de la page N° 20
1. FUNCTIONS AND CONFIGURATION 1.3 Servo amplifier standard specifications Servo Amplifier MR-E- 10A 20A 40A 70A 100A 200A Item 3-phase 200 to 230VAC, 50/60Hz or 1-phase 230VAC, 3-phase 200 to 230VAC, Voltage/frequency 50/60Hz 50/60Hz 3-phase 200 to 230VAC: Permissible voltage fluctuation 170 to 253VAC 3-phase 170 to 253VAC 1-phase 230VAC: 207 to 253VAC Permissible frequency fluctuation Within 5% Power supply capacity Refer to Section12.2 System Sine-wave PWM control, current control system Dyna