TABLE OF CONTENTS INTRODUCTION………………………………………………………………… 2 IMPORTANT SAFEGUARDS………………………………………………..….2 PACKAGE CONTAINS…………………………………………………………..2 NAMES OF PARTS……………………………………………………………….3 INSTALLATION BEFORE USE……………………………..….………………4 CONTROL PANEL AND LCD DISPLAY………….…..……………………….5 CONTROL PANEL FUNCTIONS……………………………………………….6 OPERATION USING CONTROL PANEL………………………...….…..……7 OPERATION USING REMOTE CONTROLLER…………………………..…9 MAINTENANCE……………..……………………………….…..………………9 T
Résumé du contenu de la page N° 3
INTRODUCTION Thank you for purchasing Soleus Air MAC-12K/10K portable air-conditioner. This unit is designed for improving living and working comfort by providing cooling, dehumidifying and fan functions only with a minimum installation required. With its quite operation and attractive design, you will enjoy the convenience and comfort that this unit provides for many years to come. When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room
Résumé du contenu de la page N° 4
NAMES OF PARTS 4
Résumé du contenu de la page N° 5
Exhaust Duct Window Kits INSTALLATION BEFORE USE 1) Exhaust Duct 5
Résumé du contenu de la page N° 6
When you use the unit as an air conditioner or a dehumidifier, the fresh outdoor air must be directed to the unit and the hot air must be exhausted out of the room to complete the air exchange. When the unit is operating on fan or heating models, no outdoor air exchange takes place. You do not need to hookup the window kits and exhaust hose when you use the unit as a fan or a heater. a) Pull out of both ends of the exhaust ducts for approximately 6”. b) Screw clockwise the exhaust du
Résumé du contenu de la page N° 7
CONTROL PANEL LCD DISPLAY Control Panel Functions 1) Power On/Off Control Starts or Stops the Unit 2) Mode Control Select the functions of the unit for: Fan Mode Air Conditioning Mode Heating Mode Dehumidifying Mode Auto Mode 7
Résumé du contenu de la page N° 8
3) Fan Speed Control Select the fan speed for: High Medium Slow Auto 4) Temperature/Time Select the desired temperature by pressing either ∧or ∨ key when using the unit in cooling or heating function. The LCD flashes to displays the desired temperature during the setting. The LCD displays set temperature when it is not at temperature setting mode. The buttons are also used for setting time and timer. The LTD display either in Celsius or Fahrenheit. Press Temperature/Time /
Résumé du contenu de la page N° 9
NOTE: During hot days, the unit will cool off the room most efficiently by setting the temperature at the lowest and the fan speed at the highest. Reducing the length of the exhaust duct and insulating the exhaust duct and keeping direct sunlight to a minimum will also improve the cooling efficiency. 2) Dehumidifying Operation a) Install the exhaust ducts properly b) Plug the Power Cord to the power outlet. c) Turn on the unit by pressing the On/Off Button on the control panel.
Résumé du contenu de la page N° 10
d) Press the Mode Button until the “AUTO” appears on the LCD display. e) Select the fan speed by using FAN button. During the AUTO model, the unit operates at heating mode when the room temperature is below 68 degree. It operates at dehumidifying mode when the room temperature is between 68 to 80 degree. It operates at cooling mode when the room temperature is above 80 degree. You may use the timer with the AUTO mode. 6) Sleep Mode a) The air conditioner in operatio
Résumé du contenu de la page N° 11
MAINTENANCE Note: Make sure power is off and the plug is pulled out of the power outlet before performing any maintenance activities. 1) Clean or replace filter If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended to clean the filter once every two weeks or as needed. a) Pull up the filter from the filter compartment in the back of the unit. b) Wash the air filter by immersing it gently into warm (about 104 F
Résumé du contenu de la page N° 12
c) The unit should be stored in a cool dry place. TECHNICAL SPECIFICATIONS MODEL MAC-10K MAC-12K COOLING CAPACITY 10,000 BTU/H 12,000 BTU/H HEATING 1200 W 1200 W DEHUMIDIFYING CAPACITY 50pts/Day 60pts/Day POWER COOLING 980W 1350W HEATING 1350W 1350W 3 3 AIR FLOW VOLUME 300m/h 300m /h POWER SOURCE 115 V~ 60 HZ 115 V~ 60 HZ 9/12 AMP 12/12AMP HEATING/COOLING HEATING/COOLING SOUND PRESSURE LEVEL 46 dB(A) 46 dB(A) NET WEIGHT 80 LBs 82 LBs DIMENSIONS BODY 18x32x18
Résumé du contenu de la page N° 13
CONTACT INFORMATION Contact For Optional and Spare Parts Technical Support Warranty Claim Customer Service Soleus International Inc. 9451 Telstar Ave. El Monte, CA 91731 USA (888) 8-SOLEUS www.soleusair.com 13
Résumé du contenu de la page N° 14
WARRANTY ONE YEAR LIMITED WARRANTY Soleus International Inc. warrants the accompanying Soleus Air MAC-12K/10K Mobile Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States or Canada. If the air conditioner exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of ch