Résumé du contenu de la page N° 1
AF-S50EX
AF-S60EX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION.................... 2
CONSUMER LIMITED WARRANTY ..... 3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA ........................ 4
• LOCATlON .............................................. 4
• ACCESSORIES ...................................... 5
• SUGGESTED TOOLS ............................ 5
• INSTALLATION....................................... 6
PRECAUTIONS
• CA
Résumé du contenu de la page N° 2
FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service proble
Résumé du contenu de la page N° 3
CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth be
Résumé du contenu de la page N° 4
INSTALLATION INSTRUCTIONS Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash-type windows. Minimum opening Mounting kit fully closed Mounting kit fully opened (Without mounting kit) 23 21 7 17 / " (450mm) 21 / " (550mm) 33 / " (850mm) 32 32 16 Window opening from stool to lower 27 sash bottom must be 14 / " (377mm) 32 Lower sash bottom
Résumé du contenu de la page N° 5
INSTALLATION INSTRUCTIONS ACCESSORIES 1 No. Accessories Q'ty 1 Right closure assembly 1 2 2 Left closure assembly 1 3 Window sash foam seal 1 3 Window sash foam seal 1 4 (adhesive type) 5 Bottom gasket 1 4 6 Screws (L=1", 25.4mm) 7 5 13 7 Screws (L= / ", 10mm) 6 32 6 7 8 Base pan angle 2 9 Remote control 1 10 Battery 2 9 8 10 SUGGESTED TOOLS 1. Screw driver (medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 5
Résumé du contenu de la page N° 6
INSTALLATION INSTRUCTIONS INSTALLATION WARNING: Make sure the unit is turned off and unplugged before working. Sash Cut the window sash foam seal (adhesive 1 type) to the proper length and attach it to the underside of the window sash. Window sash foam seal Sill Jamb (adhesive type) Insert the right closure assembly and the left closure assembly into the top angle 2 and the bottom channels. Secure the right and left closure to the cabinet with six of the provided screws. 13 Closure as
Résumé du contenu de la page N° 7
INSTALLATION INSTRUCTIONS Closure assembly (Left) Insert the closure assemblies on both sides into the rails of the jamb. 5 Jamb Indoor (Left) side Closure assembly (Left) Indoor side 1/2 inches (13mm) Sill Stool Loosen screws on both sides of the cabinet, then hang the base pan angle 6 on and secure the screws again. Secure the base pan angle to the sill by 7 using the hole of the front side on the angle with one screw. (L=1", 25.4mm) Top angle Secure the top angle of
Résumé du contenu de la page N° 8
PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manual. • Make sure the unit is the correct capacity for the area you want to cool. • Do not modify any part of this product. • Do not insert objects into any part of the unit. • Push the AC power plug securely into the receptacle and make sure it is not loose. • Use power circuit with a prope
Résumé du contenu de la page N° 9
PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for protection. • If a power failure occurs during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less than three minute
Résumé du contenu de la page N° 10
HOW TO OPERATE PARTS NAMES UNIT 1 Front Cabinet 4 5 6 3 2 Air Inlet (Indoor Side) 7 3 Horizontal Louvers 4 Vertical Louvers 8 5 Air Outlet (Indoor Side) 6 Control Panel 9 7 Rear Cabinet 8 Air Inlet (Outdoor side) 10 9 Filter (Pull the filter handle to 2 the right to remove.) 10 Filter Handle 11 11 1 Power Cord CONTROL PANEL 2 1 12 F POWER ON/OFF hr 11 SLEEP COOL TEMP 3 TIMER ENERGY SELECTOR ON/OFF SAVER 4 5 6 7 8 9 10 1 7 Receiver window for remote control signal TIMER ON/OFF pad 2 Display 8 TI
Résumé du contenu de la page N° 11
HOW TO OPERATE COOLING OPERATION POWER indicator COOL indicator Touch POWER ON/OFF pad. 1 • The unit is preset at 74°F and HIGH COOL. This will show in the display F POWER when the power is first turned on. ON/OFF hr • POWER indicator and COOL indica- tor will light. SLEEP COOL TEMP TIMER ENERGY To turn off the unit, touch POWER SELECTOR ON/OFF SAVER 2 ON/OFF pad again. • POWER indicator and COOL indica- tor will go off. POWER ON/OFF pad TO CHANGE FAN SPEED AND OPERATION MODE COOL indicator Dur
Résumé du contenu de la page N° 12
HOW TO OPERATE TO CHANGE TEMPERATURE SETTING During cooling operation F POWER Touch the TEMPERATURE setting ON/OFF hr pad to adjust the temperature set- ting. SLEEP COOL TEMP ---Lower temp. ---Raise temp. TIMER ENERGY SELECTOR ON/OFF SAVER • Temperature can be set within the range of 64°F to 86°F. • Display will change as you touch TEMPERATURE setting pad the pad. NOTE: • In fan only (HIGH FAN, MED FAN, LOW FAN) operation, the temperature display will go off and the temperature setting cannot be
Résumé du contenu de la page N° 13
HOW TO OPERATE ENERGY SAVER OPERATION During normal operation, the thermostat automatically controls cooling and the fan runs continu- ously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops. After the fan stops, the fan is programmed to rotate for approx. 2 minutes to detect room temperature. This will occur within a 20 min time spa
Résumé du contenu de la page N° 14
HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. • The unit will start automatically according to your setting. When the unit is not operating COOL indicator Touch the TIMER ON/OFF pad to set the 1 delayed start time. F POW
Résumé du contenu de la page N° 15
HOW TO OPERATE OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time. • The unit will stop automatically according to your setting. When the unit is operating Touch the TIMER ON/OFF pad to set the 1 delayed stop time. F POWER • The time settin
Résumé du contenu de la page N° 16
HOW TO OPERATE USING THE REMOTE CONTROL Battery compartment cover INSTALLING BATTERIES Use two size-AA (R6) batteries. Open the battery compartment 1 cover. Insert and slide the batteries into 2 the compartment, making sure the and polarities are properly aligned. Close the cover. 3 NOTES: • The battery life is approximately one year with normal use. • When you replace the batteries, always use two new ones of the same type. • If the remote control does not operate normally after rep
Résumé du contenu de la page N° 17
HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER POWER ON/OFF button POWER Push to start or stop the operation. ON / OFF TEMP. button TEMP. TEMP. ---Raise temp. setting 1°F at a time. TEMP. ---Lower temp. setting 1°F at a time. SELECTOR OFF TIMER SELECTOR button Push to change fan speed and operation mode. HIGH MED LOW HIGH MED LOW SLEEP COOL COOL COOL N N N OFF TIMER button Push to set delay "OFF" timer during operation. AIR CONDITIONER • The time setting will change as you push th
Résumé du contenu de la page N° 18
CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter before starting the unit. REMOVE THE FILTER 1 Gently pull the filter handle to the right and slide the filter out from the unit. CLEAN THE FILTER 2 To remove dust from the filter, use a vacuum cleane
Résumé du contenu de la page N° 19
BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Is the fuse blown or the circuit breaker tripped? • Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the compressor to shut
Résumé du contenu de la page N° 20
SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TH TINSEA357JBRZ 03KO 1