Résumé du contenu de la page N° 1
AF-R100CX
AF-R120CX
AF-R140CX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION.................... 2
CONSUMER LIMITED WARRANTY ..... 3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA ........................ 4
• LOCATlON .............................................. 4
• ITEMS PACKED WITH THlS UNIT ......... 5
• SUGGESTED TOOLS ............................ 5
• INSTALLATION....................................... 5
PRECAUTIONS
• CAU
Résumé du contenu de la page N° 2
FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit. MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES
Résumé du contenu de la page N° 3
CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth be
Résumé du contenu de la page N° 4
INSTALLATION INSTRUCTIONS Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash-type windows. Minimum opening Mounting kit fully closed Mounting kit fully opened (Without mounting kit) 19 1 5 22 / "(560mm) 27 / "(690mm) 38 / "(980mm) 32 32 32 Window opening from stool to lower sash bott
Résumé du contenu de la page N° 5
INSTALLATION INSTRUCTIONS ITEMS PACKED WITH THIS UNIT 1 No. Accessories Q'ty 2 1 Right closure assembly 1 2 Left closure assembly 1 1 3 Window sash foam seal 3 Window sash foam seal 4 1 (adhesive type) 4 5 Bottom gasket 1 5 6 Screws(L=1", 25.4mm) 6 8 13 7 7 Screws(L= / ", 10mm) 8 32 6 6 1 8 Remote control 9 Battery 2 8 10 Remote control hook 1 10 9 2 SUGGESTED TOOLS 1. Screw driver (medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors INSTALLATION These models can also
Résumé du contenu de la page N° 6
INSTALLATION INSTRUCTIONS (1) Unscrew the 2 screws at the corners of 2 the front panel. Keep them as they will Horizontal Louver be used later. (2) Remove the front panel by pulling the front panel at the lower corners towards you about an inch. Front panel Next lift it up and pull it towards you. Front Exhaust Lever panel CAUTION: Take care not to damage the exhaust lever when removing the front panel. Unscrew the 6 stopper screws of the (1) 3 cabinet. Keep the 4 screws from the top and fr
Résumé du contenu de la page N° 7
INSTALLATION INSTRUCTIONS Closure assembly (Left) Insert the closure assemblies on both 6 sides into the rails of the jamb. Indoor side Jamb (Left) Closure assembly (Left) 1/2 inch (13mm) Sill Stool Top angle (1) Secure the cabinet to the window 7 stool with 3 screws (L=1", 25.4 mm), working from the inside of the cabinet. (2) Secure the top angle and the closure assemblies to the window sash with 3 screws (L=1", 25.4 mm). (3) Secure the closure assemblies to the sill with 2 screws (L=1",
Résumé du contenu de la page N° 8
PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manual. • Make sure the unit is the correct capacity for the area you want to cool. • Do not modify any part of this product. • Do not insert objects into any part of the unit. • Push the AC power plug securely into the receptacle and make sure it is not loose. • Use power circuit with a prope
Résumé du contenu de la page N° 9
PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for protection. • If a power failure occurs during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less than three minute
Résumé du contenu de la page N° 10
OPERATION INSTRUCTIONS PARTS NAMES UNIT 5 6 4 7 8 3 9 10 2 1 12 11 1 Front panel Cabinet 7 2 Air inlet (Indoor side) 8 Air outlet (Outdoor side) 3 Louvers 9 Air inlet (Outdoor side) 10 Air outlet (Indoor side) Filter (Pull the filter handle to the right to remove.) 4 5 11 Exhaust lever Filter handle 6 12 Control panel Power cord CONTROL PANEL 1 2 3 HIGH COOL F MED COOL LOW COOL hr FAN ONLY TEMP TIMER ENERGY POWER SELECTOR ON/OFF SAVER ON/OFF 4 5 6 7 8 9 10 11 1 7 SELECTOR indicator TEMPERATU
Résumé du contenu de la page N° 11
HOW TO OPERATE OPERATION INSTRUCTIONS COOLING OPERATION Display / Indicator Procedure Pad Touch POWER ON/OFF F 1 pad. POWER hr ON/OFF • The unit is preset at 74°F and • POWER indicator and HIGH COOL. This will show SELECTOR indicator in the display when the power (HIGH COOL) will light. is first turned on. To turn off the unit, touch • POWER indicator and 2 POWER ON/OFF pad again. POWER SELECTOR indicator will ON/OFF go off. TO CHANGE TEMPERATURE SETTING Display / Indicator Procedure P
Résumé du contenu de la page N° 12
HOW TO OPERATE TO CHANGE FAN SPEED Display / Indicator Procedure Pad During operation • SELECTOR indicator will light in order as you touch. Touch SELECTOR pad SELECTOR and select the desired fan HIGH COOL speed. MED COOL LOW COOL FAN ONLY NOTES ON FAN SPEED HIGH COOL Fan and cooling at maximum performance. Unit is preset to HIGH COOL when first turned on after unit is plugged in. Fan operates at medium speed; cooling power at medium. MED COOL LOW COOL Cooling for sleeping com
Résumé du contenu de la page N° 13
HOW TO OPERATE ENERGY SAVER During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops.Even after the fan stops, the fan will rotate for 2 minutes, every maximum 20 minutes, to detect room temperature.) Display / Indicator Procedure Pad During coolin
Résumé du contenu de la page N° 14
HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. • You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. • Set the timer when the unit is not operating. • The unit will start automatically according to your setting. Display / Indicator Procedure Pad • SELECTOR indicator and
Résumé du contenu de la page N° 15
HOW TO OPERATE OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. • You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time. • Set the timer when the unit is operating. • The unit will stop automatically according to your setting. Procedure Display / Indicator Pad Touch the TIMER ON/ • SELECT
Résumé du contenu de la page N° 16
HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two size-AAA (R03) batteries. 1 Remove the battery compartment cover. Insert the batteries in the compartment, 2 making sure the and polarities are properly aligned. Battery compart- ment cover Replace the cover. 3 NOTES: • The battery life is approximately one year with normal use. • When you replace the batteries, always use two new ones of the same type. • If the remote control does not operate normally after replaci
Résumé du contenu de la page N° 17
HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER POWER ON/OFF POWER ON / OFF button Push to start or stop the operation. TEMP. TEMPERATURE setting button TEMP. ---Raise temp. setting 1°F at a time. TEMP. TEMP. ---Lower temp. setting 1°F at a time. SELECTOR HIGH COOL SELECTOR button MED COOL Push to change fan speed, or to select SET TIMER/OFF fan only mode. LOW COOL Fan speed selections are shown to the FAN ONLY right. SET TIMER / OFF button Push to set delay "OFF" timer dur
Résumé du contenu de la page N° 18
CLEANING AND ENERGY EFFICIENCY TIPS MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter before starting the unit. REMOVE THE FILTER 1 Gently pull the filter handle to the right and slide the fil
Résumé du contenu de la page N° 19
BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Is the fuse blown or the circuit breaker tripped? • Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the compressor to shut
Résumé du contenu de la page N° 20
SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TL TINSEA297JBRZ 01LO 1 20