Résumé du contenu de la page N° 1
MAF3364LC/LP/MC/MP SERIES
MAE3182LC/LP, MAE3091LC/LP
SERIES
MAG3182LC/LP/MC/MP,
MAG3091LC/LP/MC/MP SERIES
DISK DRIVES
PRODUCT MANUAL
C141-E064-03EN
Résumé du contenu de la page N° 2
REVISION RECORD Edition Date published Revised contents 01 Nov., 1998 02 May, 1999 03 Oct., 1999 MC/MP types are added. Specification No.: C141-E064-**EN The contents of this manual is subject to change without prior notice. All Rights Reserved. Copyright 1999 FUJITSU LIMITED C141-E064-03EN i
Résumé du contenu de la page N° 3
This page is intentionally left blank.
Résumé du contenu de la page N° 4
FOR SAFE OPERATION Handling of This manual This manual contains important information for using this product. Read thoroughly before using the product. Use this product only after thoroughly reading and understanding especially the section “Important Alert Items” in this manual. Keep this manual handy, and keep it carefully. FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering damange to their property. Use the product according to this manual. Func
Résumé du contenu de la page N° 5
Related Standards Specifications and functions of products covered by this manual comply with the following standards. Standard (Text) No. Name Enacting Organization ANSI X3.131-1986 American National Standard for American National Information Systems—Small Computer Standards Institute System Interface (SCSI) (ANSI) ANSI X3.131-1994 American National Standard for American National Information Systems—Small Computer Standards Institute System Interface - 2(SCSI-2) (ANSI) X3T9.2/85-52 Rev 4.B COMM
Résumé du contenu de la page N° 6
PREFACE This manual describes the MAF3364LC/LP/MC/MP (hereafter, MAF series), MAE3182LC/LP, MAE3091LC/LP, (hereafter, MAE series), and MAG3182LC/LP/MC/MP, MAG3091LC/LP/MC/MP (hereafter, MAG series), 3.5-inch fixed disk drives with an embedded SCSI controller. This manual details the specifications and functions of the above disk drive, and gives the requirements and procedures for installing it into a host computer system. This manual is written for users who have a basic understanding of fixed
Résumé du contenu de la page N° 7
CONVENTIONS This manual uses the following conventions for alerts to prevent physical or property damages to users or by standards. DANGER DANGER indicates that personal injury will occur if the user does not perform the procedure correctly. WARNING WARNING indicates that personal injury could occur if the user does not perform the procedure correctly. CAUTION CAUTION indicates that either minor or moderate personal injury may occur if the user does not perform the procedure correctly. NOT
Résumé du contenu de la page N° 8
DISCLAIMER Failure of the MAF series, MAE series and MAG series intelligent disk drive is defined as a failure requiring adjustments, repairs, or replacement. Fujitsu is not responsible for drive failures caused by misuse by the user, poor environmental conditions, power trouble, host problems, cable failures, or any failure not caused by the drive itself. The suffix of the model name of the disk drive varies depending on the electrical requirements, capacity, and data format at factory shipmen
Résumé du contenu de la page N° 9
Important Alert Items Important Alert Messages The important alert messages in this manual are as follows: A hazarous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. This alert signal also indicates that damages to the produt or other property, may occur if the user does not perform the procedure correctly. Task Alert message Page Mounting Installation Heat 4-10 An air flow with an adequate wind velocity must be maintained to dea
Résumé du contenu de la page N° 10
MANUAL ORGANIZATION PRODUCT 1. General Description MANUAL 2. Specifications 3. Data Format (This manual) 4. Installation Requirements 5. Installation 6. Diagnostics and Maintenance SCSI Physical 1. SCSI Bus Interface 2. SCSI Message Specifications 3. SCSI Bus Error Recovery Processing SCSI Logical 1. Command Processing Interface 2. Data Buffer Management Specifications 3. Command Specification 4. Sense Data and error Recovery Procedure 5. Disk Medium Management Maintenance 1. Spec
Résumé du contenu de la page N° 11
This page is intentionally left blank.
Résumé du contenu de la page N° 12
CONTENTS page CHAPTER 1 GENERAL DESCRIPTION .......................................................................... 1-1 1.1 Standard Features ........................................................................................................... 1-2 1.2 Hardware Structure......................................................................................................... 1-5 1.3 System Configuration.......................................................................................
Résumé du contenu de la page N° 13
4.3 Connection Requirements .............................................................................................. 4-16 4.3.1 68 pin connector 16-bit model (LP/MP)......................................................................... 4-16 4.3.2 SCA2 type SCSI model (LC/MC) .................................................................................. 4-24 4.3.3 Cable connector requirements ........................................................................................ 4-2
Résumé du contenu de la page N° 14
A.2 Locations of Connectors and Setting Terminals (LP/MP models: 68 pin type LVD 16-bit SCSI)............................................................ A-3 APPENDIX B SETTING TERMINALS................................................................................ B-1 B.1 Setting Terminals............................................................................................................ B-2 APPENDIX C CONNECTOR SIGNAL ALLOCATION .................................................... C-
Résumé du contenu de la page N° 15
FIGURES page 1.1 MAF series LC/MC outer view ...................................................................................... 1-5 1.2 MAF series LP/MP outer view ....................................................................................... 1-6 1.3 MAE series LC outer view ............................................................................................. 1-6 1.4 MAE series LP outer view.....................................................................................
Résumé du contenu de la page N° 16
4.17 AC noise filter (recommended) ...................................................................................... 4-15 4.18 Connectors and terminals location (LP/MP)................................................................... 4-16 4.19 16-bit SCSI interface connector...................................................................................... 4-17 4.20 Power supply connector (16-bit SCSI model) ................................................................ 4-17 4.21 Ext
Résumé du contenu de la page N° 17
TABLES page 2.1 Function specifications................................................................................................... 2-2 2.2 Environmental/power requirements................................................................................ 2-4 2.3 SCSI function specifications........................................................................................... 2-7 3.1 Zone layout and track capacity (MAE series).............................................................
Résumé du contenu de la page N° 18
CHAPTER 1 GENERAL DESCRIPTION 1.1 Standard Features 1.2 Hardware Structure 1.3 System Configuration This chapter describes the feature and configuration of the intelligent disk drives (IDD). IDDs are high performance large capacity 3.5-inch fixed disk drives with an embedded SCSI controller. The interface between the IDD and host system is based on SCSI (Small Computer System Interface) standard [ANSI X3.131 - 1986: Small Computer System Interface (SCSI), ANSI X3.131-1994: Small Computer System
Résumé du contenu de la page N° 19
1.1 Standard Features (1) Compactness Since the SCSI controller circuit is embedded in the standard 3.5-inch fixed disk drive form factor, the IDD is extremely compact. The IDD can be connected directly to the SCSI bus of the host system . (2) SCSI/CCS standard The IDD provides not only SCSI basic functions but also the following features: • Arbitration • Disconnection/reselection • Data bus parity • Command set which meets the logical specification of the SCSI CCS (Common Command Set for Direc
Résumé du contenu de la page N° 20
Note: The maximum data transfer rate in asynchronous mode may be limited by the response time of initiator and the length of SCSI bus length. The maximum data transfer rate in synchronous mode may be limited by the cable length, transmission characteristics of the SCSI bus and the connected SCSI device number. (5) Continuous block processing The addressing method of data blocks is logical block address. The initiator can access data by specifying block number in a logically continuous data spa