Résumé du contenu de la page N° 2
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 185 H Standard PAC SPW CR 184 GVH56B PIPING SUCTION 1/2" LIQUID 1/4" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 20 g/m MAXIMUM PIPING LENGTH 40m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY 16a Single Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 WIRING
Résumé du contenu de la page N° 3
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 255 H Standard PAC SPW CR 254 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 20a Single Phase - GVH8B 10a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Résumé du contenu de la page N° 4
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 365 H Standard PAC SPW CR 364 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 25a Single Phase - GVH8B 10a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Résumé du contenu de la page N° 5
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 485 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 32a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Résumé du contenu de la page N° 6
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 1:1 Inverter 605 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 40a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Résumé du contenu de la page N° 7
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 2:1 Inverter 125 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Résumé du contenu de la page N° 8
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 2:1 Inverter 255 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" LIQUID 3/8" GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 40 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56B 32a Single Phase - GVH8B 16a Three Phase REMOTE CONTROLLER WIRING SUGGESTED CABLE SIZE 0.75
Résumé du contenu de la page N° 9
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 3:1 Inverter 165 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Résumé du contenu de la page N° 10
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 3:1 Inverter 185 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Résumé du contenu de la page N° 11
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 4:1 Inverter 125 H Standard PAC SPW CR 484 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56
Résumé du contenu de la page N° 12
Sanyo Quick Connect Guide Indoor Unit Model Outdoor Unit Model SPW 4:1 Inverter 165 H Standard PAC SPW CR 604 GVH56B / GVH8B PIPING SUCTION 5/8" to joint 1/2" from joint to indoor LIQUID 3/8" to joint 1/4" from joint to indoor GAS PRE CHARGE LENGTH 30m ADDITIONAL CHARGE 3/8" = 40 g/m & 1/4" = 20 g/m MAXIMUM PIPING LENGTH 50m INTERCONNECTING WIRING SUGGESTED CABLE SIZE 0.75 mm (Shielded) NUMBER OF CORES 2 POWER SUPPLY WIRING INDOOR UNIT POWER SUPPLY 5a Single Phase OUTDOOR UNIT POWER SUPPLY GVH56