Résumé du contenu de la page N° 1
C, CT, CWTF Series
Including DV, APS/TC/TS,
Single CW & Twins
Supercedes Operating Manuals:
10690.####; 10737.####; 10841.0000;
28182.0000; 36102.0000
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
Résumé du contenu de la page N° 2
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor. 2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) C
Résumé du contenu de la page N° 3
INTRODUCTION This equipment will brew one or two half-gallon batches of coffee simultaneously into awaiting dispensers (with just the press of a button). One side may include a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter. USER NOTICES ........................................................................................................................................... 4 ELECTRICAL REQUIREMENTS ...................................................
Résumé du contenu de la page N° 4
USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. As directed in the International Plumbing Code of the ! WARNING International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), Fill water tank before turning - on - this equipment must be installed with adequate thermostat or connecting appliance backflow preventio
Résumé du contenu de la page N° 5
ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. BLK RED BLU L1 L2 L3 BLK 120V. A.C. L1 WHI 120V. A.C. 230V. A.C. N WHI RED 200 or 230V. A.C. 208 or 240V. A.C. RED N L2 230V. A.C. L2 120V. A.C. 230V. A.C. BLK BLK L1 L1 P3516 Earth Ground Chassis Ground P1842 P1841 Earth Ground
Résumé du contenu de la page N° 6
PLUMBING REQUIREMENTS-CURRENT SINGLES As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow pre- vention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area. MODEL C: This model is completely portable and requires no attached plumbing.
Résumé du contenu de la page N° 7
PLUMBING REQUIREMENTS-CURRENT TWINS TWINS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi 1 (138 and 620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 3 kPa) . The water inlet fitting is ⁄8" flare. 1. Remove six screws securing rear utility cover (if equipped). FIG 7-1 2
Résumé du contenu de la page N° 8
PLUMBING REQUIREMENTS-EARLY SINGLES As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow pre- vention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area. MODEL C: This model is completely portable and requires no attached plumbing. M
Résumé du contenu de la page N° 9
PLUMBING REQUIREMENTS-EARLY TWINS TWINS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi 1 (138 and 620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 3 kPa) . The water inlet fitting is ⁄8" flare. TWINS 1. Remove six screws securing rear utility cover (if equipped). FIG 9
Résumé du contenu de la page N° 10
INITIAL SET-UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. 2. Place an empty dispenser under the funnel. 3. Place the heater switch at the rear of the brewer in the “OFF” lower position and connect the brewer to the power source. 4. Fill the tank with water as directed: 4A. Model C Pour three pitchers of tap water into the screened area on top of the b
Résumé du contenu de la page N° 11
the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved. To decrease a batch size, Press and release the START or BREW switch once for every two-second interval to be removed from the total brew time period; then immediately press and hold down the START or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third cl
Résumé du contenu de la page N° 12
OPERATING CONTROLS ON/LOWER SWITCH Placing the "ON/LOWER" switch in the "OFF" (lower) position stops brewing. Stopping a brew cycle after it has been started, will not stop the flow of water into the funnel until the tank siphons down to its proper level. Placing the switch in the "ON" (upper) position enables the brew circuit and on all (except APS/TC models) sup- plies power to the brew station warmer. START SWITCH Momentarily pressing and releasing the switch starts a brew cycle. DO NOT H
Résumé du contenu de la page N° 13
OPERATING CONTROLS MASTER ON/OFF SWITCH(S) The master ON/OFF switch disables power the entire brewer (including tank heaters). NOTE – TWINS with 2 power cords will have 2 power switches, (one left, one right). TANK HEATER ON/OFF SWITCH(S) The tank heater ON/OFF switch disables power to the tank heater circuits only. Power to brew timer and warm- er circuits are not affected. All Twins have 2 tank heater switches. NOTE: Leaving the tank heater switch(s) off will result in brewing with cold wat
Résumé du contenu de la page N° 14
COFFEE BREWING ® 1. Insert a BUNN filter into the funnel. 2. Pour the fresh coffee into the filter and level the bed of grounds by gently shaking. 3. Slide the funnel into the funnel rails. 4. Place an empty dispenser beneath the funnel. 5. Place the "ON/OFF" switch in the "ON" upper position. Momentarily press and release the start switch. 6. When brewing is completed, simply discard the grounds and filter. HOT WATER FAUCET The hot water faucet may be used to dispense a cup of hot water at any
Résumé du contenu de la page N° 15
CLEANING 1. The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. Use care when cleaning around the heater switch with a cloth, so as not to accidentally turn off the tank heater! 2. Clean out the sprayhead holes. A properly cleaned sprayhead will leave a dimple in the bed of coffee grounds for each hole. Example: 6 holes = 6 dimples. FIG 15-1/2 3. With the sprayhead removed, insert the deliming spring (
Résumé du contenu de la page N° 16
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel. • All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the
Résumé du contenu de la page N° 17
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming 1. Lime Build-up (A) Use deliming spring. (B) Clean sprayhead. (Page 11) Dripping from sprayhead 1. Syphon System The brewer must be level or slightly lower in front to syphon properly. Brew cycle starts when ON/ Auxiliary brew start switch on Move objects away from brewer. TWINS inadvertently activated. LOWER Switch is turned on. 1. Filter Type Weak beverage BUNN® paper filters must be used for proper extr