Introduction 1 Dear Customer, Congratulations! You have selected the new Pure hea- ring instruments from Siemens. These instructions as well as the guidance from your Hearing Care Professional will help you understand how your new Pure hearing instruments work. If you have any further questions, please contact your Hearing Care Professional. 3
Résumé du contenu de la page N° 4
A Contents 1 2 Your Pure hearing instrument 6 3 Intended use 7 4 General notes on safety 8 5 Handling of standard and rechargeable batteries 10 6 - Low battery indicator 10 - Inserting the battery 11 - Removing the battery 12 Inserting and removing your hearing instrument 13 7 - Inserting your hearing instrument 13 - Removing your hearing instrument 14 8 Turning your hearing instrument on and off 15 Changing the hearing program 16 9 10 e2e wireless 2.0 17 11 Maintenance and care 18 Domes and Rec
Résumé du contenu de la page N° 5
A 1 2 Handling of the Receiver Unit 23 13 - Remove Receiver Unit 23 - Attach Receiver Unit 23 14Accessories 24 - Remote control 24 - Charger 25 - Tek wireless enhancement 26 Troubleshooting tips 28 15 Technical information 30 16 Disposal information 32 17 Your hearing instrument configuration 33 18 5
Résumé du contenu de la page N° 6
Your Pure hearing instrument 3 1 Features: 4 2 1 Receiver Unit 5 2 Dome 3 3 Battery compartment 4 Push Button 7 5 Microphone Cover 2 6 6 Receiver Mold 7 C-Guard 7 CAUTION Risk of injury caused by incorrect use of Domes. Always wear the Receiver Unit with the Dome. Make sure that the Dome is completely attached to the Receiver Unit. If the Dome remains in your ear, have it removed by a medical professional. Replace the Dome if it breaks. Insert the Receiver Unit with the Dome carefully an
Résumé du contenu de la page N° 7
Intended use 4 Hearing instruments are intended to improve the hearing of hearing impaired persons. Diagnosis and prescription of a hearing instrument must be performed by hearing health specialists, e.g. ENT doctors, audiologists or acou- sticians. Read and follow the instructions of this user guide to avoid injuries or damage to the hearing instrument. Symbols: Be aware of information marked with the warning symbol WARNING, CAUTION or NOTICE! WARNING points out a situation that could lead
Résumé du contenu de la page N° 8
General notes on safety 5 NOTICE Your hearing instrument is sensitive to extreme heat, high humidity, strong magnetic fields (> 0.1T), X-rays and mechanical stress. Do not expose your hearing instrument to extreme temperature or high humidity. Do not leave it in direct sunlight. Do not wear it in the shower or when you apply make- up, perfume, aftershave, hairspray or suntan lotion. Do not wear your hearing instrument when you are exposed to short-waves, a strong magnetic field, a high
Résumé du contenu de la page N° 9
General notes on safety 5 NOTICE for batteries Leaking batteries damage the instrument. Remove batteries when the instrument is not in use for a prolonged period of time. Turn your hearing instrument off when not in use to preserve the battery. WARNING Risk in explosive environments, e.g. mining areas! Don't use your hearing instruments (and remote con- trol) in areas where there is a danger of explosions. 9
Résumé du contenu de la page N° 10
Handling of standard and rechargeable batteries 6 Use standard batteries or rechargeable batte- ries in your hearing instruments. Always use size 312 batteries. Charge the rechargeable batteries before first use. original size Remove the tab on your batteries only when you are ready to use them. The positive (+) side of the batteries is always the smooth side. Always keep spare batteries with you. Low battery indicator Your Hearing Care Professional can activate an acoustic signal to
Résumé du contenu de la page N° 11
Handling of standard and rechargeable batteries 6 Inserting the battery Open the battery compartment completely using your fingernail as shown in the illus- tration. Insert the proper size battery so that the "+" symbol on the battery aligns with the "+" marked on the battery compartment. Close the battery compartment by gently pressing the bottom of the door upward with your finger tip. Do not force the door shut. If it does not close easily, check to see if the battery was inserted pr
Résumé du contenu de la page N° 12
Handling of standard and rechargeable batteries 6 Removing the battery Open the battery compartment complete- ly. Normally the battery drops out when the compartment is completely open. If the battery does not come out, lightly tap the instrument or push the battery out with a pencil as shown. Do not throw used batteries into household trash. Return them to your Hearing Care Professional for environmentally correct disposal. 12
Résumé du contenu de la page N° 13
Inserting and removing your hearing instrument 7 NOTICE Do not use lubricant when you insert the Dome/ ear- mold, because it may clog the sound outlet. NOTICE For hearing instruments with earmold, handle by holding the earmold. Do not pull the tube. Inserting your hearing instrument Turn your hearing instrument off. Hold the receiver with the Dome/ Receiver Mold bet- ween your thumb and index fin- ger and insert it carefully into the ear canal. You may find it helpful to pull your ear sli
Résumé du contenu de la page N° 14
Inserting and removing your hearing instrument 7 Removing your hearing instrument Turn your hearing instrument off. Hold the Receiver Unit/ Receiver Mold between your thumb and index finger and carefully pull it out. You may find it helpful to lightly push your ear from the back. CAUTION The ear tip needs to be attached properly. If the ear tip remains in the ear, it has to be removed by Hearing Care Professional. 14
Résumé du contenu de la page N° 15
Turning your hearing instrument on and off 8 Turn on: Press the push button for 2 seconds to turn the instrument ON. Turn off: Press the push button for 2 seconds to turn the instrument OFF. You can also use the remote control to turn the hea- ring instrument on and off. Power-on delay Your hearing instrument is equipped with a „power-on-de- lay“ feature which can be activated by your Hearing Care Professional. This allows you to turn the hearing instru- ment on with an automatic delay, s
Résumé du contenu de la page N° 16
Changing the hearing program 9 Your hearing instruments offer up to 5 hearing pro- grams for specific listening environments. Each time you press the program button, your hea- ring instruments switch to the next program, confir- ming each change with an acoustic signal. Example Turn your hearing instruments on. It is automatically in program 1. You want to change to program 2. Press the program button once. You hear the acoustic signal for program 2. You are now in program 2. If you are w
Résumé du contenu de la page N° 17
e2e wireless 2.0 10 Your hearing instruments are equipped with e2e (ear-to- ear) wireless 2.0 technology. Advantages of the wireless functionality: Automatically adjusts both hearing instruments simulta- neously to different listening situations. Allows use of accessories, e.g. a remote control. Provides synchronization of the settings in the system. If you change the volume or program on one hearing in- strument, the other hearing instrument is automatically adjusted. Your Hearing Care Pro
Résumé du contenu de la page N° 18
Maintenance and care 11 Your hearing instruments are highly sensitive systems. Proper care and handling will ensure the best possible performance. Clean instruments regularly to prevent damage to the hearing instruments and to avoid health problems. Clean your hearing instruments with a soft, dry tissue, as necessary. If the hearing instruments sound distorted or weak ask your Hearing Care Professional to exchange the micro- phone cover. Place your hearing instruments in a "dry aid kit"
Résumé du contenu de la page N° 19
Domes and Receiver Molds 12 Your hearing instrument has either a Dome or a Receiver Mold. Dome Receiver Mold C-Guard Domes and Receiver Molds include integrated C-Guard wax protection system. Full functionality of Domes and Receiver Molds is only assured with a working C-Guard. Have the C-Guard exchanged approximately every three months. 19
Résumé du contenu de la page N° 20
Domes and Receiver Molds 12 Daily cleaning NOTICE Domes, Receiver Molds and C-Guards are easily dama- ged when handled wrongly. Never use brushes or sharp objects for cleaning. Never use running water or immerse the hearing in- strument. Never use pressure or rotating action while cleaning. Don't spray cerumen solvent directly onto the C-Guard! Do not pull the receiver out of the Receiver Mold. Cerumen (ear wax) on the C-Guard affects sound quality. Remove wax with a soft tissue. No othe