Résumé du contenu de la page N° 1
685
OWNERS MANUAL
For
COFFEE BREWERS
MODELS:
0412 Decanter (In-Line)
0443 Decanter (In-Line
Pour-Over)
0471 Decanter (Step-up
Pour Over)
0472 Decanter (Step-Up)
Model: 0482 Airpot Brewer
0482 Airpot/Thermal
Server
Includes:
Model: 0443 Pour-Over
Decanter Brewer
Installation
Operation
Use & Care
Servicing Instructions
Model: 0412 In-Line
Decanter Brewer
Model: 0472 Stepped –Right
Decanter Brewer
PRINTED IN
Résumé du contenu de la page N° 2
685 77110 Owners Manual Horizon™ Brewers WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based u
Résumé du contenu de la page N° 3
TABLE OF CONTENTS WARRANTY STATEMENT xi Thank You for purchasing this Bloomfield Industries appliance. SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 Proper installation, professional PRECAUTIONS & GENERAL INFORMATION 3 operation and consistent AGENCY LISTING INFORMATION 4 maintenance of this appliance will ensure that it gives you the very INSTALLATION INSTRUCTIONS
Résumé du contenu de la page N° 4
685 77110 Owners Manual Horizon™ Brewers FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS Fig. 1 Features & Operating Controls for Automatic Brewers 2
Résumé du contenu de la page N° 5
FEATURES AND OPERATING CONTROLS - POUR-OVER BREWERS Fig. 2 Features & Operating Controls for Pour-Over Brewers 3 685 77110 Owners Manual Horizon™ Brewers
Résumé du contenu de la page N° 6
685 77110 Owners Manual Horizon™ Brewers PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable e
Résumé du contenu de la page N° 7
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and IMPORTANT: condition. Ensure that all packing materials have been removed To enable the installer to make from the unit. a quality installation and to minimize installation time, the Verify that the Spray Head Gasket and Spray Disk are properly following suggestions and tests installed. should be done before the actual unit installation is sta
Résumé du contenu de la page N° 8
685 77110 Owners Manual Horizon™ Brewers INSTALLATION (continued) READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION CAUTION: PLUMBER’S INSTALLATION INSTRUCTIONS (AUTOMATIC BREWERS) ELECTRICAL DAMAGE Brewer should be connected to a POTABLE WATER, COLD DO NOT plug in or energize this WATER line. Flush water line before connecting to Brewer. appliance until all Installation DO NOT use a saddle valve with a self-piercing tap for the water Instructions are read and
Résumé du contenu de la page N° 9
INSTALLATION (continued) ELECTRICIAN’S INSTALLATION INSTRUCTIONS WARNING: REFER TO ELECTRICAL SPECIFICATIONS - Page 1 SHOCK HAZARD Check the nameplate to determine correct electrical service Brewer must be properly required for the Brewer to be installed. grounded to prevent possible IMPORTANT: Before connecting to electricity, make sure shock hazard. DO NOT automatic brewers are connected to the water supply. assume a plumbing line will provide such a ground.
Résumé du contenu de la page N° 10
685 77110 Owners Manual Horizon™ Brewers OPERATION IMPORTANT: A. START-UP TANK MUST BE FULL For initial start-up, or if the brewer has not been used for an OF WATER BEFORE extended period of time: CONNECTING BREWER TO ELECTRIC POWER. ♦ Be sure spray disk and brew gasket are properly installed in the brew head. Heating elements will be damaged if allowed to ♦ Be sure the water supply is properly connected and the wate
Résumé du contenu de la page N° 11
BREWING COFFEE A. PREPARATION CAUTION: Place one (1) genuine Bloomfield paper filter in the brew chamber. BURN HAZARD Add a pre-measured amount of fresh coffee grounds. Exposed surfaces of the Gently shake the brew chamber to level the bed of grounds. brewer, brew chamber, Slide the brew chamber into place under the brew head. decanter and/or airpot may be HOT to the touch, and can cause serious burns. CAUTION: BURN HAZA
Résumé du contenu de la page N° 12
685 77110 Owners Manual Horizon™ Brewers CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Brewing and serving Allow brewer to cool. temperatures of coffee are extremely hot. FREQUENCY: Daily Hot coffee will cause serious skin burns. TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Br
Résumé du contenu de la page N° 13
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will self- reset Damaged internal component Examine wiring & connectors, or wiring thermostat and heating element Repair/replace as needed Coffee level too high or low
Résumé du contenu de la page N° 14
685 77110 Owners Manual Horizon™ Brewers SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD WARMER PLATES: Opening access panels or Warmer plates unscrew counter-clockwise. removing warmer plates on this brewer may expose uninsulated TOP PANEL: electrical components. Remove top panel to access hot water tank, thermostat, heating Disconnect brewer from elements, brew circuit tubing, faucet valve and piping, and top- electrical power before m
Résumé du contenu de la page N° 15
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Disconnect brewer from electric power. Remove top panel. Remove button plug from front panel. These procedures involve exposed electrical circuits. Pull vent tube out of tank lid and insert a thermometer of known These procedures are to be accuracy in hole. Reconnect brewer to electrical power. performed by qualified Place empty container under brew chamber. Energize br
Résumé du contenu de la page N° 16
685 77110 Owners Manual Horizon™ Brewers SERVICING INSTRUCTIONS (continued) IMPORTANT: TIMER ADJUSTMENT (AUTOMATIC BREWERS ONLY) Water pressure must be The amount of water dispensed automatically during a brew cycle between 20 p.s.i and 90 p.s.i. is controlled by the timer. flowing pressure. If water pressure exceeds this value, Place empty decanter (for Model 0482, use an airpot) under brew or if water pressure varies chamber. Press BREW button. Brewer shoul
Résumé du contenu de la page N° 17
SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. NOTE: Wrench p/n 86660 is designed to allow easy removal of the hoses from the plastic solenoid valve. IMPORTANT: Shut-off water and disconnect brewer from electric power before removing hoses or wiring. Remove top cover and detach solenoid access door from cabinet. Remove faucet tube from faucet valve at fl
Résumé du contenu de la page N° 18
685 77110 Owners Manual Horizon™ Brewers SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY Disconnect brewer from electric power. Remove front panel. Remove three screws holding timer to bracket. Disconnect wiring to timer. Reassemble in reverse order. Adjust timer as described on page 14. IMPORTANT: When replacing water faucet REPLACE HOT WATER FAUCET COIL coil, also replace seal gaskets. Symptom: Brewer drips continuously from brew head, except
Résumé du contenu de la page N° 19
SERVICING INSTRUCTIONS (continued) PROCEDURE: Delime the Water Tank CAUTION: CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals may be FREQUENCY: As required (Brewer slow to heat) caustic. Wear appropriate TOOLS: Deliming Solution protective gloves and goggles Protective Gloves, Goggles & Apron during this procedure.
Résumé du contenu de la page N° 20
685 77110 Owners Manual Horizon™ Brewers EXPLODED VIEW & PARTS LIST PLUMBING & RELATED COMPONENTS - AUTOMATIC BREWERS MODELS: 0412, 0472, 0482 18