Résumé du contenu de la page N° 1
Household MRV
Ceiling Concealed Type Room Air Conditioner
AE092FCAHA
AE182FCAHA
0010570925
A
Résumé du contenu de la page N° 2
1
Résumé du contenu de la page N° 3
2
Résumé du contenu de la page N° 4
AE092FCAHA AE182FCAHA 3
Résumé du contenu de la page N° 5
AUTO AUTO Part description Remote controller Heating operation indication Dehumidifying operation indication Cooling operation indication Fan only operation indication Automatic operation Operation indicator Clock display Power ON/OFF key R Used to turn on /off the machine. TIMER ON display Sleep status indication ROOM TEMP AM PM SET TEMP AM TIMER OFF display TIMER ON PM Temperature display AM LOW MIN HIGH TIMER OFF ion PM Fan speed display Automatic louver indication L L M L M H L M H TIMER
Résumé du contenu de la page N° 6
Warning for installation Important Points of Safety The following four important points of safety and suggestions should be paid great attention: ! Warning: Misuse may cause fatal result such as death or serious injury etc. ! Attention: Misuse may cause human injury or damage of machine, in some case fatal results. : Content marked with this ìforbiddenî sign should be absolutely forbid- den, otherwise may cause damage of machine and human
Résumé du contenu de la page N° 7
Warning for use Warning for move and repair Attention points for installation Important Points of Safety ! Warning l Avoid your body being blown l If something abnormal (e.g.: burnt directly by cold wind for long smell etc.) occurs, stop running the period, otherwise your health machine, shut down the manual may be affected. power switch and contact after service. Continuous operation in l Donít extend your fingers or disorder may cause fire hazar
Résumé du contenu de la page N° 8
Attention points for use Important Points of Safety Attention * Ensure ventilation of the room* DONíT lay any burning facilities if the machine is used with in place where winds produced by burning facilities. Deficient the machine can reach. Incomplete ventilation can cause oxygen combustion of burning facility may shortage. be caused otherwise. * Check whether installation bench of the machine is * DONíT clean the machine with
Résumé du contenu de la page N° 9
AUTO AUTO Operating instructions AUTO, FAN operation 1 Unit start Press the "ON/OFF" key to turn on the unit. The LCD on the remote controller displays the previous operating conditions (excluding previous timer , sleep and louver conditions). The remote controller operation indicator turns on. R 4 2 Select operation mode 1 AM Press the "MODE" key to alter the working mode. Each ROOM TEMP pressing will change the operation mode in the following LOW MIN HIGH sequence: AUTO COOL DR Y F AN HEA
Résumé du contenu de la page N° 10
AUTO AUTO Operating instructions COOL, DRY, HEAT operation Recommended operation mode: 1 Unit start Press the "ON/OFF" key to turn on the unit. Please use cooling mode in summer and heating mode in winter. The LCD on the remote controller displays the prev- Please use DRY mode in spring or ious operating conditions (excluding previous timer , autumn humid climate. sleep and louver conditions). The remote controller operation indicator turns on. 2 Select operation mode Press the "MODE" key to alt
Résumé du contenu de la page N° 11
AUTO Operating instructions TIMER ON/OFF function Please adjust the clock before using timer function. You may set the air conditioner automatically turn on or turn off when you wake in the early morning, come off work or after you fall asleep. 1. Set the operation mode after the unit is turned on. R The operation indicator on the remote controller turns on, and the LCD screen displays the operation mode. 1 AM ROOM TEMP AM TIMER ON LOW MIN HIGH 2. Setting the timer mode Press the "TIMER" key to
Résumé du contenu de la page N° 12
AUTO Operating instructions TIMER ON-OFF operation 1. After unit starts, select your desired operation mode. R The operation indicator turns on and the operation mode is 1 AM ROOM TEMP displayed on the LCD screen. AM TIMER ON AM LOW MID HIGH TIMER OFF 2. Timer mode selection 3 TIMER CLOCK SWING TIME SLEEP TEMP 2 4 FAN SET MODE SPEED 5 6 TIMER ON TIMER OFF TIMER ON BLANK TIMER OFF AM AM AM 12:00 12:00 12:00 AM 12:00 TIMER ON TIMER OFF TIME
Résumé du contenu de la page N° 13
AUTO Operating instructions SLEEP function Using SLEEP function R Before using this function, the time must be checked and set. After the unit starts, set the operation status, AM SET TEMP then press "SLEEP" key. LOW MIN HIGH Before going to bed, you can press the "SLEEP" key on the remote controller and the air condit- SWING TIMER CLOCK ioner will operate in comfortable SLEEP mode TIME SLEEP TEMP FAN and bring you a sound sleep. SET MODE SPEED Operation Mode In COOL/DRY mode Sleep operation sta
Résumé du contenu de la page N° 14
Troubleshooting The following cases are not troubles. Water flow sound is heard. During operation, the air conditioner may sometimes exhibit a sound of "clatter" or "Hua-Hua" "rumble". This is the common sound of refrigerant flow but not a trouble. This is caused by the thermal expansion A sound of "Pi-Pa" is generated. or cold shrinkage of plastics. Sometimes there are smells in the air flow Smells are given off. from the indoor unit. This is caused by the smell of cigarettes or paint coatings
Résumé du contenu de la page N° 15
Troubleshooting In DRY operation, when the room temper- During DRY operation, there is no air ature reaches 2* higher than temp. sent out or fan speed cant be changed. setting,the unit will run at "lOW"fan speed regardless of fan speed setting. In HEAT mode, the outdoor unit This occurs during removal of the frost generates water or steam. (in defrosting operation) on the radiator of outdoor unit. Defrost operation In HEAT mode, the indoor fan still After the unit stops, the indoor fan will kee
Résumé du contenu de la page N° 16
When fault occurs Poor cooling or heating Is the operation controller Is there any door or window Are there any obstructs adjusted as required? left open? before the air inlet or outlet? Poor cooling Is there any other heat Is there any direct sunlight Are there too many people source in the room? into the room? in the room? If, after the above checks and the corresponding corrective actions, the system remains abnormal operation, or the following facts appear, please turn off the air conditione
Résumé du contenu de la page N° 17
Notice to users Notice to users l To ensure proper operation of the system, the user shall follow this instruction manual to install the unit. l When handling the air conditioner, please be care not to scratch the case surface. l This instruction manual describes the installation method aided with the installation tools specified by Qingdao Haier Air Conditioner Electronics Com., Ltd. l The maximum length of connection pipe is 50 m, and the maximum difference between levels of
Résumé du contenu de la page N° 18
Installation precautions Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. ! The below attentive matters are divided into" Warning " and "! two parts. When the Note" wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in ! part. But even the items listed in "! Note" " Warning" part can also cause serious accidents. Above all, both the two parts
Résumé du contenu de la page N° 19
Installation precautions ! Attention This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd. ! Warning This instruction manual must be read carefully before beginning of installation, improper ins- tallation may cause accidents and thus bring about machine damage and personal casualty. Installing tools 1. Screw driver 6. Pipe cutter 10. Leak
Résumé du contenu de la page N° 20
Installation procedure Electrical requirements l The power supply shall be connected from the outdoor side. (For models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side The power cord size is 3 x (1.25-1.5)mm2, type of YZW). l A separate power circuit shall be supplied and connected by a qualified electrician according to the wiring rules specified in the corresponding national standard. l A current leakage break