i i SAFETY WARNING CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents The engine exhaust from this product contains are known to the State of California to cause can- chemicals known to the State of California to cause cer, birth defects, and other reproductive harm. cancer, birth defects, or other reproductive harm. The Above For Diesel Engines The Above For Gasoline Engines ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY
Résumé du contenu de la page N° 3
ii ii SAFETY ELECTRIC SHOCK can ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover kill. plates to protect your eyes from sparks and 3.a. The electrode and work (or ground) circuits the rays of the arc when welding or observing are electrically “hot” when the welder is on. open arc welding. Headshield and filter lens Do not touch these “hot” parts with your bare should conform to ANSI Z87. I standards. skin or wet clothing. Wear dry, hole-free gloves to insulate hands. 4.b. Us
Résumé du contenu de la page N° 4
iii iii SAFETY WELDING SPARKS can CYLINDER may explode cause fire or explosion. if damaged. 6.a. Remove fire hazards from the welding area. 7.a.Use only compressed gas cylinders If this is not possible, cover them to prevent containing the correct shielding gas for the the welding sparks from starting a fire. process used and properly operating Remember that welding sparks and hot regulators designed for the gas and materials from welding can easily go through small cracks pressure used. All hos
Résumé du contenu de la page N° 5
iv iv SAFETY zones où l’on pique le laitier. PRÉCAUTIONS DE SÛRETÉ 6. Eloigner les matériaux inflammables ou les recouvrir afin de Pour votre propre protection lire et observer toutes les instructions prévenir tout risque d’incendie dû aux étincelles. et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- 7. Quand on ne soude pas, poser la pince à une endroit isolé de antes: la masse. Un court-circuit accidental peut provo
Résumé du contenu de la page N° 6
v v for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product Thank You ��� as much pride as we have in bringing this product to you! Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment
Résumé du contenu de la page N° 7
vi TABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Safety Precautions ..........................................................................................A-2 Select Suitable Location..................................................................................A-2 Stacking
Résumé du contenu de la page N° 8
A-1 A-1 INSTALLATION TECHNICAL SPECIFICATIONS - INVERTEC V350-PRO INPUT AC VOLTAGE & DC OUTPUT Product Ordering Input AC Rated DC Output Output Weight Dimensions Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD (continuous) K1728-1 Factory Factory 82.5lbs 200 350A / 34V / 60% (37.4 kg) 14.8” x 13.3” x Invertec K1728-2 208-230/ 27.8”* V350- Construction 380-400/ AMPS Construction (373 x 338 x PRO 415-460/ 5-425 81.5lbs.
Résumé du contenu de la page N° 9
A AMPS V VOLTS WELD TERMINALS A OUTPUT SELECT ! WARNING ! ATTENTION ! ! AVISO DE L Lo o e er rm m p ps iis u uW m m d do o o o ll r rA s stt a a ii m me ettR c c o on n s s e e c c ttN e ettu ueera a rdI di ppiN i s sic cn ng g ii G LLo o e em P r rm p p iis s u uR m m d d o o o o llE r rs stt a am ii me eC tt c c o on n s s e eAU c c tte ettu ue e a a r rd d p p ii s siic cC n ng g ii ION L Lo or a a e e r o o m m lle ee ee tit r r,e e p p ,ll itte ii s s u u d d d do o m m d do o d d a allo o
Résumé du contenu de la page N° 10
A-3 A-3 INSTALLATION Cobramatic Connection Instructions LN-7 Connection Instructions A Cobramatic can only be used with the “Factory” & An LN-7 can only be used with the “Factory” & “Advance Process” versions of the 350-Pro. “Advance Process” versions of the 350-Pro. � Turn the Invertec power switch "off" � Turn the Invertec power switch "off". � Connect the control cable from the Cobramatic to � Connect the K480 control cable from the LN-7 to the the 24/42 VAC 14-pin wire feeder MS-style
Résumé du contenu de la page N° 11
A-4 A-4 INSTALLATION PARALLEL OPERATION The V350-Pro are operable in parallel in CC mode. For best results, the currents of each machine should be reasonably well shared. As an example, with two machines set up in parallel for a 400 amp procedure, each machine should be set to deliver approximately 200 amps, not 300 amps from one and 100 amps from the other. This will minimize nuisance shutdown conditions. In general, more than two machines in parallel will not be effective due to the voltag
Résumé du contenu de la page N° 12
B-1 B-1 OPERATION SAFETY PRECAUTIONS OPERATIONAL FEATURES and CONTROLS: UPPER CONTROL PANEL WARNING 1. AMPS Meter ELECTRIC SHOCK can kill. � Prior to STICK or TIG operation (current flow), the � Do not touch electrically live parts or meter displays preset current value (either 2 amps electrode with skin or wet clothing. or +/- 3% (e.g. 3 amps on 100), whichever is � Insulate yourself from work and greater). ground. � Prior to CV operation, the meter displays four dash- � Always wear dry insulat
Résumé du contenu de la page N° 13
B-2 B-2 OPERATION For all versions, these trigger modes can be over-ridden 7. WELD MODE SELECT - FACTORY AND (switched) with the WELD TERMINALS push button. When CONSTRUCTION (See Figure 1) changed, the unit will power up in the configuration it was in The Mode Control button selects from the following when it was last powered down. welding modes. 5. THERMAL CC-STICK SOFT: The Stick Soft process features � This status light indicates when the power source has continuous control ranging from 5
Résumé du contenu de la page N° 14
B-3 B-3 OPERATION � The Hot Start control is not used in the CV-FLUX � The Arc Control regulates the relative Slope of the CORED mode. process. Slope dynamically controls the force the � The Arc Control regulates pinch effect. At the mini- arc has to penetrate an open root. At the minimum mum setting (-10), minimizes pinch and results in a setting, Arc Control is very soft and is similar to the soft arc. At the maximum setting (+10), maximizes Stick Soft mode. At the maximum setting, the slope
Résumé du contenu de la page N° 15
B-4 B-4 OPERATION 7A. ADVANCED PROCESS PANEL � Pulsed Modes (See Figure 2) In Pulse Modes; The work point will be in the Amps window and To program Welding modes. Select knob is used to should be set close to the wire feed speed of the Scroll through all Welding modes. The Memory button wire feeder in inches per minute. The Volts window is used to store and access Welding modes into loca- will have SPd displayed indicating Wire Feed tions M1 thru M8. Speed. Once current starts flowing and durin
Résumé du contenu de la page N° 16
B-5 B-5 OPERATION 5. After all adjustments have been made press and CONTROLS: (See Figure 2) hold the Memory button until the display changes. The right and the left window will display what The MEMORY button and SELECT knob are used memory to save in, lets say M1. To store in M1 together to select a welding process an store it in (M1 push the Memory button again to save the Pulse thru M8). The SELECT knob scrolls through the, Mig mode to memory M1. welding process modes and memory modes M1 thru
Résumé du contenu de la page N° 17
B-6 B-6 OPERATION WELD MODE DETAILS: Mode Range Comments Stick Soft 5 - 425 amps The stick soft mode is the best selection for general stick applications. Arc Control = Arc Force Hot Start = Initial hot start current (min = start a match set amps, Max. = greatest hot start current) During hot start, arc force is set at high and is fast response. For gouging applications: Turn current up to 425 amps. Stick Crisp 5 - 425 amps The stick crisp mode features an aggressive arc force routine well suit
Résumé du contenu de la page N° 18
B-7 B-7 OPERATION PULSE PROGRAMS: .030 Steel 65 - 1200 The V350 non synergic pulse programs allow independent control .035 Steel 55 - 800 of the wire feed speed and the arc length. The V350 Output Control .045 Steel 50 - 700 Knob adjusts the arc length similar to other processes. When oper- .052 Steel 75 - 550 ating in a pulse mode, the V350 displays a reference number as .045 Metal Core 50 - 650 the relative arc length. (Range given in center column.) Setting this .052 Metal Core 50 - 500 refer
Résumé du contenu de la page N° 19
B-8 B-8 OPERATION CC-Stick modes LOWER CASE PANEL � The remote will default to only the 6-pin MS-style The output studs, line switch and remote connector connector if a remote is connected to it. are located on the lower case front. � The WELD TERMINAL control will default to ON with or without a remote connected. 9. Both STUDS contain "Twist-Mate" connector inserts. Types of Remote OUTPUT CONTROL � The Negative stud is configured to accept the � The Invertec V350-Pro’s Output Control can be c
Résumé du contenu de la page N° 20
B-9 B-9 OPERATION DESIGN FEATURES and ADVANTAGES LIMITATIONS � Multiple process DC output range: 5 - 425 amps � The V350-Pro is not recommended for processes � Presettable welding outputs. other than those listed. � Built-in Line Voltage Compensation holds the output � The V350-Pro can only be used with the recom- constant over +/- 10% input fluctuations. mended equipment and options. � State of the art inverter technology yields high power efficiency, excellent welding performance, RECOMMENDED