Résumé du contenu de la page N° 1
INSTALLATION AND OPERATION INSTRUCTIONS
TM
Vent-Free Millivolt
Dual-Listed Gas Log Sets
Gas Train Models:
Log Set Models:
LSVFSD-NG
LSVFSD-18 Logs
LSVFSD-LP
LSVFSD-24 Logs
Log Sets Sold Separately LSVFSD-30 Logs
P/N 850051M Rev. C, 03/2011
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
In the Commonwealth of Massachusetts:
Portland
• Installation must be performed by a licensed plumber or gas fitter
US
Shadowdance™ Series
• See Table of
Résumé du contenu de la page N° 2
IMPORTANT SAFETY AND WARNING WARNINGS INFORMATION • Allow the appliance to cool before servicing. Always shut off any electricity or gas to the appliance while READ THIS MANUAL IN ITS ENTIRETY AND UNDER- performing service work. STAND THESE RULES TO FOLLOW FOR SAFETY. • The appliance and its individual shut-off valve must be disconnected from the gas supply piping system while WARNINGS performing any tests of the gas supply piping system at If the information in this manual is
Résumé du contenu de la page N° 3
CONGRATULATIONS! PACKAGING LIST the gas train models lsVFsD-Ng and lsVFsD-lP are packaged with When you purchased your new gas log heaters, you joined the the following: ranks of thousands of individuals whose answer to their home 1 - one base/grate assembly heating needs reflects their concern for aesthetics, efficiency and 2 - one bag of lava rock 3 - one damper clamp our environment. We extend our continued support to help you 4 - o ne literature package, which consists of the insta
Résumé du contenu de la page N° 4
SEE TABLE 3 ON PAGE 16 FOR BTU INPUT AND GAS PRESSURE CODES REQUIREMENTS adhere to all local codes or in their absence the latest edition of the Do not install these Dual-Listed Gas Log Appliances in a bedroom or National Fuel gas code aNsi Z223.1 or NFP a 54-latest edition which can a bathroom as all units exceed maximum allowable BTU/hr input of be obtained from the american National standards institute, inc. (1430 10,000. Broadway, New York, NY, 10018) or National Fire Protection associ
Résumé du contenu de la page N° 5
NEW YORK COMBUSTION AND VENTILATION AIR installation of these gas log heaters are approved in the state of New York and are prohibited in New York city. t his heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. t he heater may be located in unusually tight construc- tion provided the space is unconfined, or if confined, is provided with two MASSACHUSETTS REQUIREMENTS permanent openings c
Résumé du contenu de la page N° 6
4. compare the maximum Btu/Hr the space can support with the actual Note: Illustrations shown in this manual reflect “typical” installations amount of Btu/Hr used. with nominal dimensions and are for reference only. Actual installations may vary due to individual design preferences. However, always main- _________ Btu/Hr tain minimum clearances to combustible materials and do not violate (max. the space can support) any specific installation requirements. Refer to Figures 2 through 8 for
Résumé du contenu de la page N° 7
Noncombustible Material Requirements with No Mantel Installed (A) Noncombustible Requirements for Safe Installation Material Measurement 12" or more adjustable canopy not required. 42" 8" minimum to 12" install adjustable canopy. Min. less than 8" extend noncombustible material to at least 8" and install adjustable canopy (Figure 4). 16" or Min. extend noncombustible material to a height of at least 12". Table 1 Noncombustible Material Heights and Mantel Location Figure 2 - Clearances (A) Non
Résumé du contenu de la page N° 8
Example: The bottom of the mantel may project from the wall a maxi- INSTALLATION mum of 2-1/2" at a minimum of 8" above the opening. The top shelf of the mantel may project a maximum of 6" at a minimum of 14-1/2" above the opening. WARNINGS • Do not use a blower insert, heat exchanger 12" insert or other accessory not approved 10" for use with this heater. 8" • Installed decorative glass door enclosures must be 26" 6" fully opened when operating this dual-listed gas 22-1/2" applia
Résumé du contenu de la page N° 9
the appliance gas inlet connection is 3/8" NPt at the regulator/valve, r eplace the test point plug after pressure measurement ensuring no located on the left side facing the appliance. if a right side connection is gas leaks. required, the connection pipe may be piped under the rear of the appliance to end at the left hand side for connection to the inlet. When tightening up the joint to the regulator hold the regulator securely Step 4. PLACING THE LOGS with a wrench to prevent the regulator
Résumé du contenu de la page N° 10
4. Place left and right front logs onto front grate locating pins as LOG PLACEMENT INSTRUCTIONS shown in Figure 14. 1. Place rear ember bed as shown in Figure 11. Top Burner Install Right Front Log Left Front Log Ember bed from behind Locating top burner Pins Rear Ember Bed Position Ember Bed All the Way Locating Pins Indicated by Arrows Forward in Gas Train Assembly Figure 14 - Install Left and Right Front Logs Figure 11 - Install Rear Ember Bed 2. Place rear log onto the two rear grate lo
Résumé du contenu de la page N° 11
7. Place the right top log onto rear log locating pin and the right 9. Place the front ember bed log as shown in Figures 18A and front log locating pin as shown in Figure 17. 18B. Right Top Log 18" Gas Log Set Locating Pins Figure 17 - Install Right Top Log 24" Gas Log Set 8. Place l eft t op t wig (24" and 30" models only) onto corresponding notch on rear log as shown in Figure 18A. the front of the left t op t wig should be up against and behind the left top log. Left Top Log Left Top Twig
Résumé du contenu de la page N° 12
Burner And Flame Characteristics WARNING the shadowdance™ gas log set features a new concept in integrated Failure to position the parts in accordance with Figure burner and log design. the flames from the burner travel horizontally through the log set and emerge at the knot holes. 21 or failure to use only parts specifically approved with this appliance may result in property damage or t he flames are slightly blue off the burner and as they progress through the log set, they chan
Résumé du contenu de la page N° 13
only limited cleaning will be required under the normal use of the appli- OPERATION AND CARE OF YOUR APPLIANCE ance. Dust the front grate, the top of the piezo cover and the control knob occasionally. Do not use cleaning fluids to clean the logs or any other 1. Appliance operation may be controlled through the ON/OFF unit part of the appliance. rocker switch, located in the bottom front of the appliance or through an optional remote control. r emove the log set, gently handling at each end.
Résumé du contenu de la page N° 14
Deluxe Remote Control System ACCESSORY COMPONENTS (Model RC-STAT) t he model rcl -t (Deluxe) r emote control system All options are available in kit form, are easy to install and are pack- has all of the features of the standard system aged complete with all required parts and instructions. Some of the along with an added easy to read lcD screen option kits need to be fitted prior to completing the installation of the which presents access to many enhancements, appliance. The following p
Résumé du contenu de la page N° 15
Charred Ember Kit ACCESSORY COMPONENTS (CONTINUED) an optional 2-piece charred ember Kit is available to enhance the beauty of the Gas Log Sets log set. Left Charred Ember Right Charred Ember 18" Gas Log Set Charred Ember Kit* Cat. No. Model No. Description H6894 LSVFSD-CEK Charred Ember Kit (ref form #750252M) * This kit is standard with the 30" Log Set 24" Gas Log Set Shadowdance Burner Assemblies Cat. No. Model No. Description H8304 LSVFSD-NG Shadowdance NG Burner H8305 LSVFSD-LP Shadowdance
Résumé du contenu de la page N° 16
CAUTION: Label all wires prior to disconnection when servicing controls. THERMOPILE Wiring errors can cause improper and dangerous operation. PILOT (O.D.S.) If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. ASSEMBLY MILLIVOLT VALVE WHITE RED WHITE WHITE IGNITION ON/OFF WIRE SWITCH OPTIONAL REMOTE CONTROL PILOT PIEZO (MILLIVOLT) IGNITER Figure 23 - Millivolt Wiring Diagram Vented/Unvented Gas Log Appliance Technical Chart For Milliv
Résumé du contenu de la page N° 17
O O L I P T O it TPTH TP TH L I P F F LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. this appliance has a pilot which must be lighted with a piezo • Immediately call your gas supplier from a neighbor’s phone. igniter. When lighting the pilot, follow these instructions Follow the gas supplier's instructions. exactly. • If y
Résumé du contenu de la page N° 18
VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. igniter electrode positioned wrong. replace igniter. pressed, there is no spark B. igniter electrode broken. replace igniter. at oDs/pilot. C. igniter electrode not connected to igniter cable. reconnect igniter cable. D. igniter cable pinched or wet. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry. E. Piezo igniter nut is loose. t ighten nut. F. Broken igniter
Résumé du contenu de la page N° 19
REPLACEMENT PARTS LIST (MILLIVOLT) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") No. Description Catalog Number 1. Valve, millivolt (Natural) H1203 Valve, millivolt (Propane, l.P.g.) H4278 2. ember Bed Front H3910 3. ember Bed rear H3911 4. Bottom Burner H3912 5. t op Burner H3913 6. Piezo igniter 10K86 7. oDs Pilot assembly, millivolt (Natural) H4113 8. oDs Pilot assembly, millivolt (Propane, l.P.g.) H4170 9. Knob
Résumé du contenu de la page N° 20
WARRANTY Normally, all parts should be ordered through your lennox Hearth Products distributor or dealer. Parts will be shipped at prevailing prices Your gas appliance is covered by a limited warranty (provided with at time of order. appliance). Please read the warranty to be familiar with its coverage. When ordering repair parts, always give the following information: r etain this manual. File it with your other documents for future reference. 1. the model number of the appliance. PRODUCT RE