Résumé du contenu de la page N° 1
INSTALLATION AND OPERATION MANUAL
TM
Direct-Vent Gas
Fireplace Heater Inserts
The Shoreline™ fireplace insert is factory equipped for 40,000 BTU
input and can be converted to 33,000 using the smaller orifice provided.
Retain These Instructions For Future Reference
P/N 850,050M Rev. C, 01/2008
A French manual is available upon request. Order P/N 850,050CF. Ce manuel d’installation
est disponible en francais, simplement en faire la demande. Numéro de la pièce 850,050CF.
In the Commonwealth of
Résumé du contenu de la page N° 2
Refer to the National Fuel Gas Code and local zoning and IMPORTANT SAFETY AND WARNING code authorities for details on installation requirements. Your fireplace insert must be vented to the outside in accordance INFORMATION with the latest edition of the National Fuel Gas Code. 8. This gas insert MUST be vented directly to the outside and READ THIS MANUAL IN ITS ENTIRETY AND UNDER- MUST NEVER be attached to a chimney serving a separate STAND THESE RULES TO FOLLOW FOR SAFETY. solid fuel bur
Résumé du contenu de la page N° 3
This installation manual will help you obtain a safe, efficient, depend- CONGRATULATIONS ON THE PURCHASE OF YOUR NEW able installation foryour appliance and vent system. GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH PRODUCTS. PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS When you purchased your new gas-fired heater, you joined the ranks BEFORE BEGINNING YOUR INSTALLATION of thousands of individuals whose answer to their home heating needs reflects their con
Résumé du contenu de la page N° 4
Fuel GENERAL INFORMATION This insert comes from the factory equipped to burn natural gas from 0 to 2,000 feet (610 M) of elevation in the USA and 0 - 4,500 feet (1372 Table 1shows the BTU input for eachmodel: M) in Canada. The insert can be converted to burn LP (liquid propane) by installing a conversion kit. Only Lennox Hearth Products conversion Millivolt Models with Manually-Modulated Gas Valves kits can be used to convert from N
Résumé du contenu de la page N° 5
Manufactured Home Installations - These appliances must conform Questions To Ask Local Building Official to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (in Canada CAN/CSA Z240 MH) (in Canada CAN/CSA These appliances must be installed per manufacturers’ instructions. Z240 MH), or when such a standard is not applicable, the Standard Installations must conform to appropriate local codes and applicable for M
Résumé du contenu de la page N° 6
Inspection NEW YORK CITY, NEW YORK (MEA) The state or local gas inspector of the side wall horizontally vented gas Installation of these fireplaces are approved for installation in New York fueled equipment shall not approve the installation unless, upon inspection, City in the US state of New York (MEA#: 138-07-E). the inspector observes carbon monoxide detectors and signage installed inaccordance with the provisions of 248 CMR 5.08(2)(a)
Résumé du contenu de la page N° 7
SPECIFICATIONS: Shoreline™ Note: Due to Lennox’ ongoing commitment to quality , all specifications, ratings and dimensions are subject to change without notice. Insert Dimensions Inches (millimeters) A Left front of unit to center line 13-1/8 (333) B Right front of unit to center line 17-1/4 (438) C Left rear of unit to center line 9 (9) P D Right Rear Of Unit To Center Line 7-5/8 (194) E Center Of Air Intake To Center Line 6-3/4 (17) F Center Of Flue To Center Line (51) G Insert Depth In
Résumé du contenu de la page N° 8
MINIMUM CLEARANCES TO COMBUSTIBLES Mantel - 1 ” Depth These appliances can be installed in most fireplace configurations. If installed close to an adjacent wall, ensure that the minimum clearances Combustibles Trim or Mantel Depth of 8” or Less to combustible surfaces are maintained. A local building inspector should reviewyour plans prior to installation. F Refer to Figures 2 through 4 for clearances to combustibles. Minimum clearances include any projections
Résumé du contenu de la page N° 9
INSTALLATION CAUTIONS Fireplace Requirements • The fireplace in which this gas insert is to be installed must be thoroughly cleaned if it has These heaters are designed to be installed into an existing masonry been used to burn wood or synthetic logs. Have fireplace (built to UBC 37 or ULC S628 standards) or factory built solid the chimney and all inside surfaces of the fire- fuel, wood burning fireplace (listed to UL 127 or ULC S610) only. All pla
Résumé du contenu de la page N° 10
Venting Requirements Positive Flue Connection (acceptable methods for sealing chimney throat) Masonry and Factory Built Fireplaces Approved Vent Systems: A qualified installer should evaluate the existing fireplace to determine the Lennox Hearth Products Co-linear Chimney Liner Kit Recommended: best method for achieving a positive flue connection between the vent and intake liners and the chimney. One method is to secure a noncombus- • The Flex Kit, Cat.
Résumé du contenu de la page N° 11
Vertical Venting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap (see Figure 6b) or it can terminate inside the chimney (see Figure 6a). The bottom opening of the chimney must be sealed around the vent pipes if the combustion air vent is not
Résumé du contenu de la page N° 12
SHORELINE™ DOOR ASSEMBLY INSTALLATION OR REMOVAL INSTRUCTIONS Tools Needed: Notools are needed Cat. No. Description H5746 Shoreline Door Assembly (Figure 9) Shoreline Door Kit - Packaging List Models SHR33 & SHR40 Quantity Description 1 Shoreline Door Assembly Figure 11 Table 6 - (refer to Figure 9) 3. Pull the louvers out to the farthest point and then lift up. Push door against the face of the insert. Drop the louvers down and let the Note: The Shoreline
Résumé du contenu de la page N° 13
2. Next place the rear panel (C). It will set on the bracket mounted to the SHORELINE™ REFRACTORY BRICK INSTALLATION INSTRUCTIONS blowermounting plate on the back ofthe firebox.See Figure 16. Tools Needed: No toolsare needed Cat. No. Model Description 75383 SHR-BRICK-STD Brick Panel Set, Standard 75384 SHR-BRICK-RED Brick Panel Set, Red 75391 SHR-BRICK-ARCHSTONE Brick Panel Set, Architectural (shown) C Refractory Brick Panel Kits - Packaging List Models SHR33 &
Résumé du contenu de la page N° 14
SHORELINE™ LOG SET INSTALLATION INSTRUCTIONS CAUTIONS Tools Needed: No toolsare needed • If logs are not installed according to the log installation instructions, flame impingement Cat. No. Description H5747 5-Piece Ceramic Log Set and improper combustion could occur and result in soot and/or excessive production of carbon Log Set - Packaging List monoxide (CO), a colorless, orderless, toxic Models SHR33 & SHR40 gas. Quantity Description • The size and position of the log set i
Résumé du contenu de la page N° 15
4. Place left log (C) on pin in back. Push log against left side of refractory 2. Separate the glowing embers (F) into quarter size pieces and place along ports on burner pan. DO NOT cover burner secondary holes in front. See Figure 24. on burner pan. The pattern for the glowing embers should be similar towhat isshown in Figure 22. pin F C Figure 24 5. Locate groove in center log (B), and place the top of the right log (
Résumé du contenu de la page N° 16
SHORELINE™ SURROUND ASSEMBLY INSTALLATION Hook A Tools Needed: No tools areneeded One of the following surround kits is required (Purchased sepa- rately). Surround Kits Models SHR33 & SHR40 Part/Cat. # Description Dimensions 75387 Small 3-sided Flange 36-5/8”W x 25-7/8”H 75385 Small 4-sidedFlange 36-5/8”W x 29-3/16”H Figure 29 75388 Large3-sided Flange 41”Wx 28”H 75386 Large 4-sidedFlange 41”W x 33-1/2”H Table 9 2 Slide the insert into its final location in the fireplace.
Résumé du contenu de la page N° 17
SURROUND BALL SCREW MOUNT ADJUSTMENT C Tools Needed: 7/16”wrench Flat End Screwdriver Adjustment Procedure: Ball Screw Step 1 Open the surround access door. Inspect the tension or lack of Latch tension while opening the door to determine if it should open easier or tighter. Step With the access door open you will see the ball screw latch as shown in Pictures A and B. Using a 7/16” wrench, loosen the jam nut on the ball screw assembly as shown
Résumé du contenu de la page N° 18
Tables 10 and 11 show the units' gas pressure requirements for GAS LINE INSTALLATION these appliances. We recommend that a qualified individual such as a plumber or gas fitter be Inlet Gas Supply Pressure used to correctly size and route the gas supply line to the appliance. Installing a gas supply line from the fuel supply to the appliance involves numerous Fuel # Minimum Maximum Desired considerations of materials, protection, sizing, locations,
Résumé du contenu de la page N° 19
CAUTION Pilot Hood Your Shoreline™ gas appliance must always be Igniter (electrode) Thermopile operated with glass door in place. Thermocouple Lighting Instructions STOP! Read the safety information on the front cover of the manual before proceeding. 1. Open the right side access door. Ensure the gas supply shut-off cocks are Pilot Assembly open and ON/OFF Rocker Switch is “OFF”. If equipped with a thermostat, set it to the lowest setting. Figure 32
Résumé du contenu de la page N° 20
Flame Appearance and Sooting CAUTIONS Your Shoreline™ fireplace insert is designed for maximum heating efficiency. Therefore, upon lighting of the main burner the flames will be • Carbon will be produced if the air shutter is semi-transparent or “bluish.” After 10-20 minutes of operation the logs closed too much. Any damage due to carboning will heat up and the flames will become a yellow/orange color. If after 20 minutes the flame stay