Résumé du contenu de la page N° 1
Watertile Rainshower
Installation and User Guide
MODEL NUMBERS
8030A
Important! Please quote the above model number(s) when ordering spares
IMPORTANT
INSTALLER: THIS MANUAL IS THE PROPERTY OF THE
CUSTOMER AND MUST BE RETAINED WITH THE PRODUCT
FOR MAINTENANCE AND OPERATIONAL PURPOSES.
1071288-AN2-F 09/03/12
1
Résumé du contenu de la page N° 2
BEFORE YOU BEGIN All information is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. Please leave these instructions for the consumer. NOTES: 1. Flush the water supply pipes thoroughly to remove any debris. 2. An in line water filter must be used with this product. 3. Inspect the supply pipes for damage. Replace as necessary. 4. Observe
Résumé du contenu de la page N° 3
SPECIFICATION Pressures The minimum recommended operating pressure is 1.5 bar. For multiple outlets an operating pressure of 3.0 bar or greater is recommended to ensure optimum performance. Plumbing Connections Mixed water from a valve must be connected to the inlet of a pressure balance loop. Building in Depth Note! Minimum building in depth is 79 mm. It is recommended that a minimum stud wall cavity of 100 mm is provided to ease installation. INSTALLATION Before you Begin 1. Turn off the wa
Résumé du contenu de la page N° 4
Install the Supply Pipework - Single Supply Pressure Balancing Loop 127 mm 127 mm Soldering Template G1/2" Nipple G1/2" Male Thread Pressure Adapter with Flow Control Balancing Loop Soldering Template 1. Install the water supply pipes. 2. Use the soldering template to construct a pressure balancing loop, this will ensure correct alignment with the product. Note! The loop pack is made from stronger pipe to give the pipework rigidity. It is not standard copper pipe. 3. Assemble the pressure bal
Résumé du contenu de la page N° 5
Install the Support Framework Existing Ceiling 229mm Joist 2 x 2 (50 mm x 50 mm) 2 x 4 (50 mm x 100 mm) 2 x 4 (50 mm x 100 mm) 368 mm Typical 2 x 2 (50 mm x 50 mm) 2 x 4 50 mm x 100 mm) Existing 30 mm Pressure Ceiling 2 x 4 Balancing Joist (50 mm x 100 mm) Existing Loop Ceiling Joist 1. Construct the support framework as shown in the above diagram. The 2 x 2 should be offset 30 mm from the edges of the 2 x 4’s to support the pressure balancing assembly at the correct depth. 2. Install the sup
Résumé du contenu de la page N° 6
Install the Pipe Nipples 1. Remove the pipe nipples. Note! The minimum distance between the face of the tees/elbows and the surface of the finished ceiling should be 57 mm. The measurement for typical installations is 70 mm. 2. Measure the distance from the face of the tees/elbows to the surface of the finished ceiling. Make any adjustments as needed. 3. Install the nipples into the tee/elbows hand tight. 4. Measure the distance form the end of the nipples to the surface of the finished ceilin
Résumé du contenu de la page N° 7
3. Install the adapter onto one of the nipples using the 11 mm bit (supplied), 11 mm or 7/16” socket, the extension and the socket wrench. Note! Use masking tape to hold the bit in place, as the bit could fall off and cause damage. Important! The concealing plate should sit loosely at this point. If it is tight against the ceiling, use a longer pipe nipple. 4. Align the groove in the waterway with the double ribs on the leak shield. 5. Press the waterway into place over the adapter. Secure
Résumé du contenu de la page N° 8
6. Applying pressure evenly, press the membrane seal into the sprayhead groove. Install the Sprayface Ribs Finished Ceiling Sprayface Setscrews 1. Tilt the sprayhead downward so that the ribs on the top of the sprayhead are exposed. Note! For product with brushed finishes, align the brush pattern of the sprayfaces with the direction of the brushed pattern of the concealing plate. 2. Insert the grooves of the sprayface over the ribs of the sprayhead. 3. Press the sprayface down to cover the sp
Résumé du contenu de la page N° 9
SPARE PARTS 1054349 Template 1059024** Escutcheon 1051498 Nipple G1/2” 1056179 3/16” Wrench 1036043 Shield 1055988 1055233 Gasket Adapter 1051681 Screen Washer 1044060 O-Ring 1071652 11 mm 1032955 Hex Bit 5/64” Wrench 1041362 Wire 1045773 1036038 Base Screw 1056104 (Includes Spring Washer Clamps) 1036040 Spacer 1045772 Elbow 1047041 1045768 Washer Sprayhead 1044058 O-Ring 1036044 Clamp 1059514 1044059 Screw O-Ring 1039745 Setscrew 1051487 Nozzle 1036041** 1045769 Spray Face Sprayhead 1039745 105
Résumé du contenu de la page N° 10
1080649 Kit - Pressure Balance Loop 1097221 Flow Control 1097222 Adapter CARE AND CLEANING Like anything of lasting quality, Kohler tapware and fittings require a certain amount of periodic care to preserve their lustrous finish. Clean your new Kohler tapware and fittings with a mild soap, rinse thoroughly with warm water and dry with a clean, soft cloth. The ideal cleaning technique is to always blot dry any water from metal surfaces. Allowing water to evaporate on metal will form water deposit