Résumé du contenu de la page N° 1
The.Danger.signal.indicates.an.immediately.hazardous.situation.which,.
if.not.avoided,.will result.in.death.or.serious.injury.
The.Warning.signal.alerts.you.to.potential.hazards.or.unsafe.practices.which,.
if.not.avoided,.could result.in.severe.personal.injury.or.death.
The.Caution.signal.alerts.you.to.hazards.of.unsafe.practices.which,.if.not.avoided,.
may.result.in.minor.personal.injury.or.property.damage.
Please.be.certain.that.the.person.who.installs.or.uses.this.appliance.carefully.
reads.a
Résumé du contenu de la page N° 2
Table of Contents Warranty...........................................................................................................4 Introduction/Typical Installation . Introduction.......................................................................................4 . Typical.Installation.............................................................................4 Waste Xpress Features...................................................................................5 WX-101A Control Featu
Résumé du contenu de la page N° 3
Warranty WASTE XPRESS SYSTEM LIMITED WARRANTY ® ® The.InSinkErator .Waste.Xpress,.disposer.and.control.centers.are.warranted.against.defects.in.material.and. workmanship.for.one.year.from.the.date.of.installation..The.warranty.includes.parts.and.labor,.provided.an.. InSinkErator.Factory.Authorized.Service.Center.performs.the.service..This.warranty.does.not.apply.if.the.failure.. is.due.to:.faulty.or.improper.electrical.installation,.faulty.or.improper.plumbing.installation,.product.abuse.or.. mi
Résumé du contenu de la page N° 4
Waste Xpress Features CONSTRUCTION FEATURES Stainless.steel.construction.(for.physical.size.see.. COMPACT.SIZE ® Figure.3). The.Waste.Xpress .is.designed.to.fit.under.a.34".high commercial.kitchen.table. WASTE.MIX The.Waste.Xpress.can.process.non-food.waste.such WASTE.REDUCTION as.paper,.light.and.rigid.plastic.or.food.wrappings.when Reduces.volume.by.85%. mixed.with.a.minimum.of.50%.food.waste. SAFETY.INTERLOCK The.Waste.Xpress.is.equipped.with.safety.interlock.. on.the.discharge.chute.(see.Fig
Résumé du contenu de la page N° 5
WX-101A Control Features/Mounting Control Center ® The.WX-101A.Control.Center.is.UL .approved.for.use. with.InSinkErator.Waste.Xpress.food.waste.reduction. systems..The.control.center.operates.the.disposer.and. ELECTRICAL SHOCK Waste.Xpress..Its.main.functions.are: .•.Ensure.that.Waste.Xpress.voltage.and.phase. match.that.of.the.electrical.supply,.control.center.. •.To.start.and.stop.the.disposer/Waste.Xpress.system. &.disposer..Check.nameplate.for.specification. •.To.reverse.the.direction.of.th
Résumé du contenu de la page N° 6
Installing Disposer CLEAN.THE.DRAIN.LINE With.a.drain.line.auger,.clear.away.all.hardened.waste material.in.the.horizontal.drainpipe.running.from.the PERSONAL INJURY drain.trap.to.the.main.waste.line. .•.For.safe.operation,.The.minimum.required.distance . from.the.table.top.or.trough.to.the.mounting.flange. is.6.inches.for.standard.body.disposers.. (as.specified.by.UL)..See.Figure.5. 6" min. (152.4 mm min.) .•.Moving.shredder.parts.may.cause.serious.injury.if. a.hopper.or.cone.is.not.properly.in
Résumé du contenu de la page N° 7
InSinkErator Mounting Assemblies 4..From.the.bottom,.insert.two.screws.through.opposite STANDARD MOUNTING ASSEMBLY . sides.of.the.flat.gasket.(3).and.mounting.flange,.into 1..Place.mounting.flange.(1).over.the.existing.collar . the.threaded.fasteners.in.the.existing.flange..The . adaptor.connection.lip.or.sink.bowl.flange.(this.may . flat.gasket.is.used.only.in.the.#6.mounting.assembly. . require.some.force). . The.screws.should.protrude.about.1/4".below.the 2..Push.the.mounting.flange.up.out.of
Résumé du contenu de la page N° 8
Installing the Waste Xpress 45˚ bend shown (max of 4 can be used) 1-1/2" 3" (38.1 mm) (76.2 mm) Figure 11. Top View Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress 1-1/2" min 1" min (38.1 mm (25.4 mm min) min) Disposer Flow Control Valve Shut Off Valve (supplied by others) WX-101A Controller 10 max (3.1 m max) Figure 12. Typical Installation Diagram 9
Résumé du contenu de la page N° 9
Installing the Waste Xpress 7....Connect.wire.bundle.between.WX-101A.and.. WASTE XPRESS LOCATION Waste.Xpress.unit.as.detailed.in.wiring.diagram.. NOTE: Prior to installing the Waste Xpress the Door.interlock.connections.are.#3.and.#95..Replace. disposer and control center should be installed as terminal.cover. specified within this manual. 8....Wire.per.local.electrical.codes.and.install.. •.Position.Waste.Xpress.within.10.feet.of.the.disposer using.NEMA.4.watertight.electrical.connectors.. out
Résumé du contenu de la page N° 10
Plumbing Connections PROPERTY DAMAGE Water.connections.must.comply.with.all.local. plumbing.codes. WASTE INLET LINE Connect.the.disposer.outlet.flange.as.close.as.. possible.and.with.as.few.as.possible.90°.elbows.to.. the.Waste.Xpress.inlet. NOTE: The maximum allowable distance between the Figure 15. disposer outlet flange and the Waste Xpress inlet is 10 feet with a maximum of four (4) 90° elbows. 1..Connect.the.disposer.outlet.to.the.Waste.Xpress.. . inlet.using.2".NPT.plumbing..3.HP.will.re
Résumé du contenu de la page N° 11
Plumbing Connections WASTE OUTLET LINE WATER SUPPLY CONNECTIONS Connect.a.2".drain.line.to.the.Waste.Xpress.waste.. When.connecting.the.incoming.water.supply.to.the outlet.as.specified.per.local.codes.(see.Figure.18.. disposer,.sink.bowl.and.Waste.Xpress,.use.as.few for.water.outlet.location). elbows.and.tees.as.possible. InSinkErator.recommends.that.the.water.outlet.. All.cold.water.line.fittings.are.1/2".NPT.except.the empties.into.a.floor.drain. sink.bowl.nozzles.which.are.1/2".compression...
Résumé du contenu de la page N° 12
Electrical Connections ELECTRICAL SHOCK PROPERTY DAMAGE .•.Turn.off.all.electrical.supply.to.the.disposer.before. .•.Ensure.that.control.center.voltage.and.phase attempting.any.work.on.it..Use.a.voltmeter.or.. . match.the.disposer.motor.and.electrical.supply... circuit.tester.to.ensure.that.power.is.off. . Check.nameplates.on.disposer.and.control.. . center.for.voltage.and.phase.specifications. .•.All.Installation.work.must.conform.to.local.. plumbing.and.electrical.codes. .•.Refer.to.the.contro
Résumé du contenu de la page N° 13
Operating Instructions PRE-OPERATION TEST Before.operating.the.Waste.Xpress.complete.. the.following.steps.to.ensure.the.unit.has.been.. PERSONAL INJURY properly.installed. If.system.does.not.shut.down.when.front.. cover/discharge.chute.is.removed,.interlock.may. 1....Ensure.plumbing.and.electrical.connections.. not.be.wired.correctly..See.Troubleshooting.section. are.secure. for.corrective.action. 2....Turn.on.incoming.cold.water.supply.to.disposer.. and.hot.water.supply.to.the.Waste.Xpress. 3.
Résumé du contenu de la page N° 14
Operating Instructions TO.START 1..Check.to.ensure.disposer.is.free.of.foreign.objects. 2..Ensure.power.is.on. 3..Push.start.button..Disposer.and.Waste.Xpress.will. run.and.water.will.flow.into.disposer TO.STOP 1..Push.stop.button..System.will.stop. 2..Water.may.continue.to.flow.into.disposer.for.up.to.. 10.minutes,.per.the.time.set.on.the.water.shutoff. delay.timer..This.post-flush.clears.the.drain.lines.. of.food.waste. WATER.SHUTOFF.DELAY.ADJUSTMENT This.water.shutoff.delay.is.adjustable.from
Résumé du contenu de la page N° 15
Operating Instructions OPERATING WASTE XPRESS SYSTEM 1..Make.sure.there.are.no.foreign.objects.in.disposer. grind.chamber..Do.not.pre-load.disposer.with.food. waste.prior.to.starting. 2..Place.10.gallon.waste.bin.under.discharge.chute. 3..Push.start.button.on.control.center..Waste.Xpress. and.disposer.will.run.and.water.will.flow.into.disposer. 4..Feed.food.waste.into.disposer.in.a.steady,.. continuous.flow..Waste.will.exit.discharge.chute.. and.drop.into.waste.bin. NOTE: Once all waste has been
Résumé du contenu de la page N° 16
Cleaning Instructions PERSONAL INJURY Discharge Chute Wait.until.auger.paddles.stop.before.cleaning. Waste.Xpress. 1....Press.stop.button.on.control.center.to.stop.system. (disposer.&.Waste.Xpress). 2....Holding.both.handles.remove.discharge.chute.by.. tilting.it.upward.(see.Figure.25). 3....Remove.auger-bearing.bracket.by.sliding.the.two. captive.fasteners.inward.and.then.pull.bracket.. Figure 25. upward.(see.Figure.26.and.27). 4....Lift.auger.and.screen.up.and.then.out.. (see.Figure.26). 5....
Résumé du contenu de la page N° 17
Troubleshooting ELECTRICAL SHOCK PERSONAL INJURY •.Disconnect.power.before.servicing. Wait.until.auger.paddles.stop.before.servicing. Waste.Xpress. •.Do.not.bypass.interlock.switch. Troubleshooting.for.problems.other.than.what.is.listed.below.should.be.performed.by.a.qualified.service.person.. Troubleshooting.performed.by.untrained.personnel.could.result.in.electrical.shock.or.damage.to.the.Waste.Xpress,. disposer.and/or.Control.Center. SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The.
Résumé du contenu de la page N° 18
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Water.backs.up.into.disposer.. •. The.auger.and.screen.plugged. •. Remove.plug. (does.not.drain). •. Auger.not.turning.. •. Ensure.that.auger.is.seated.properly.and.. . that.auger.belt.in.place..Check.motor. •. Plumbing.line.between.disposer.and.. •. Remove.clog. . Waste.Xpress.clogged. Waste.Xpress,.disposer.and.water. •. Insufficient.time.allowed.after.Line.. •. Allow.15-20.seconds.prior.to.attempting.. will.start.when."sta
Résumé du contenu de la page N° 19
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION No.water.spraying.onto.. •. Solenoid.valve.clogged. •. Remove.clog. auger.screen. •. Water.turned.off. •. Turn.on.water. •. Solenoid.valve.defective. •. Call.for.service. •. Spray.nozzles.clogged. •. Replace.nozzles. •. Timer.defective. •. Call.for.service. •. Timer.not.set.properly. •. Call.for.service. •. Solenoid.valve.installed.incorrectly. •. Reinstall.solenoid.valve.so.arrow.is.pointing. . in.correct.direction. Water.fl
Résumé du contenu de la page N° 20
Troubleshooting DISPOSER TROUBLESHOOTING PROBLEM CAUSE SOLUTION Disposer.motor.will.not.start.and. •. No.incoming.line.power. •. Turn.line.power.on. water.does.not.flow. •. Line.disconnect.switch.is.not.on.. •. Turn.line.disconnect.to."on".position..Wait.. . . 15-20.seconds.before.attempting.to.start.. . system.to.allow.control.to.perform."self.test." •. Line.disconnect.switch.has.been.. •. Wait.30.seconds.and.try.starting.again.. . reactivated.and.30-second.delay.. . . has.not.yet.expired. •. L