Résumé du contenu de la page N° 1
DONOT
DISCARD
Installation
Instructions
Installation and service of this
Models:
appliance should be performed by
qualified personnel. Hearth & Home
GO24MTCH,GO30MTCH
Technologies suggests NFI certified
GO35MTCH, GO40MTCH
or factory-trained professionals,
o r t e c h n i c i a n s
Grand Oak Match Light
s u p e r v i s e d b y
Gas Log Sets
an NFI certified
professional.
Check with your local building code agency before you begin installation to ensure compliance with local codes, incl
Résumé du contenu de la page N° 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Hearth & Home Technologies The information contained in this owner’s manual, unless gas log set—an elegant and clean alternative to burning noted otherwise, applies to all models and gas control wood. The Hearth & Home Technologies gas log set you systems. have selected is designed to provide the utmost in safety, Your new gas l
Résumé du contenu de la page N° 3
WARNING WARNING Improper installation, adjustment, alteration, service HOT! DO NOT TOUCH. or maintenance can cause injury or property damage. SEVERE BURNS MAY RESULT. Refer to the owner’s information manual provided with CLOTHING IGNITION MAY RESULT. this appliance. For assistance or additional information Glass and other surfaces are hot during consult a qualified installer, service agency or the gas operation and cool down. supplier. • Keep children away. CAUTION • CAREFULLY SUPERVISE
Résumé du contenu de la page N° 4
• This appliance must have a screen in place while the appliance is in operation and, unless other provisions for WARNING combustion air are provided, the screen shall have an Fire Risk opening for introduction of combustion air. Explosion Risk • Solid fuels shall not be burned in a fireplace where a Verify inlet pressures. decorative appliance is installed. • High pressure may cause overfire • If glass doors are present, the glass doors must be fully condition. opened while appliance is i
Résumé du contenu de la page N° 5
G. Negative Pressure WARNING Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. Causes for this Asphyxiation Risk imbalance include: This appliance produces carbon monoxide • Exhaust fans (kitchen, bath, etc.). (CO). • Range hoods. • The free opening areas (in square inches) • Combustion air requirements for furnaces, water heaters of the chimney damper as shown in the and other combustion appliances. following tables must be met. • Clothe
Résumé du contenu de la page N° 6
H. Inspect the Appliance and Components I. For Natural Gas Installation • Remove the contents from the carton labeled “Burner”. • Pour sand into the burner pans to the point where the Attached to the burner are tags identifying the manufacturer burner pipe is covered. See Figure 3. Level the sand from name, serial number, model number (including gas log right to left to ensure an even flame pattern. At this point size), BTU ratings, gas type, etc. the pan should be half full. • Review the at
Résumé du contenu de la page N° 7
J. Damper Stop Installation Instructions Included in the burner assembly box is a damper stop clamp which attaches to the damper as shown (Figure 6). Install the clamp to the damper ensuring that the minimum require- ments (Tables and 2) are achieved. Use a 7/6 in. wrench to secure the clamp to the damper. If the damper clamp pro- vided does not fit your application, other means of securing the proper opening must be provided by the installer. Damper Stop Clamp Damper Figure 5 Placing Ro
Résumé du contenu de la page N° 8
K. Inspect the Venting System The fireplace venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the outside atmosphere. See fireplace installation instructions. A spillage test must be made before the installed appliance is left with the consumer. • Close all doors and windows in the home. • Light the log set (see Lighting Instructions). • After three minutes, test with a smoke match, smoke candle, stick incense or cigarette in. below the
Résumé du contenu de la page N° 9
L. GO24 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV736 SRV738 SRV737 SRV722 SRV723 SRV728 SRV724 SRV742 SRV729 SRV743 SRV727 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08 9
Résumé du contenu de la page N° 10
M. GO24 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. WARNING Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Step 1 SRV737 SRV736 SRV738 Step 2 SRV722 SRV723 Step 3 SRV729 SRV728 SRV724 SRV742 SRV743 SRV727 not shown. See page 12, Step 3 for placement of log
Résumé du contenu de la page N° 11
N. GO30 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV720 SRV726 SRV721B SRV721A SRV722 SRV723 SRV728 SRV724 SRV742 SRV740 SRV743 SRV727 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Résumé du contenu de la page N° 12
O. GO30 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. Step 1 SRV721A SRV721B SRV726 SRV720 Step 2 SR SRV722 V722 SRV723 SRV724 Step 3 SRV740 SRV728 SRV743 SRV742 SRV727 2 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Résumé du contenu de la page N° 13
P. GO35 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV709 SRV708 SRV737 SRV728 SRV716 SRV816 SRV808 SRV724 SRV707 SRV706 SRV702 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08 3
Résumé du contenu de la page N° 14
Q. GO35 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. SRV737 SRV708 SRV709 SRV728 SRV716 SRV816 SRV724 SRV808 SRV707 SRV702 SRV706 4 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Résumé du contenu de la page N° 15
R. GO40 Grand Oak Series Logs Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV700 SRV701 SRV721A SRV721B SRV728 SRV703 SRV816 SRV808 SRV724 SRV707 SRV706 SRV702 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08 5
Résumé du contenu de la page N° 16
S. GO40 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. SRV721A SRV721B SRV700 SRV701 SRV728 SRV816 SRV703 SRV724 SRV808 SRV702 SRV707 SRV706 6 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08
Résumé du contenu de la page N° 17
P. Lighting Instructions- Match Light T. Lighting Instructions- Match Light WARNING WARNING Asphyxiation Risk Asphyxiation Risk Gas-burning appliances produce smoke and Gas-burning appliances produce smoke and carbon monoxide gas during operation. carbon monoxide gas during operation. • The damper must be open • The damper must be open • The chimney must draw properly • The chimney must draw properly These fumes can be harmful if not vented These fumes can be harmful if not vented properly.
Résumé du contenu de la page N° 18
U. Cleaning and Maintenance Instructions Always remember: • Do not place any combustible material near the appliance. • Do not place any paper, trash or other material on the log set or in the heater. • Do not touch any part of the appliance when it is in operation. • Do not operate this appliance without the fireplace screen closed. CAUTION Before cleaning the appliance, be sure it is turned completely off. The appliance must be completely cooled. Your appliance is designed to be virtuall
Résumé du contenu de la page N° 19
V. Fequently Asked Questions Can I close the glass doors on my fireplace when using my gas logs? No. The gas log sets are designed for use in fireplaces with all fireplace doors fully opened. Operating your log set with the doors closed will cause overheating, premature failure of valve systems, and will void the warranty of your log set. What sort of maintenance do gas logs require? Vented gas logs do not require regular maintenance. However, it is a good idea to have valves, pilots and gas co
Résumé du contenu de la page N° 20
W. Replacement Parts Grand Oak Gas Logs Service Parts Exploded Parts Diagram Beginning Manufacturing Date: N/A MTCH GO Gas Logs Ending Manufacturing Date: Active GO24 & 30 4 3 2 1 5 GO35 & 40 6 8 7 2A 1 20 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08 4 3 2 1