Résumé du contenu de la page N° 1
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND
INSTALLATION MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
NATURAL GAS “VICTORIAN” MODEL (V)V42ENA(1) SERIES
PROPANE/LP GAS “VICTORIAN” MODEL (V)V42EPA(1) SERIES
WARNING: If the information in this manual is not fol-
WARNING: Improper installation,
lowed exactly, a fire or explosion may result causing
adjustment, alteration, service,
property damage, personal injury, or loss of life.
or maintenance can
Résumé du contenu de la page N° 2
TABLE OF CONTENTS SAFETY INFORMATION 2 TABLE OF CONTENTS CLEANING AND MAINTENANCE ............................................ 27 SAFETY INFORMATION ............................................................ 2 TROUBLESHOOTING .............................................................. 28 PRODUCT IDENTIFICATION ..................................................... 3 ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 30 LOCAL CODES .............................................................
Résumé du contenu de la page N° 3
SAFETY INFORMATION 3 PRODUCT IDENTIFICATION 3 LOCAL CODES SAFETY INFORMATION PRODUCT IDENTIFICATION Continued Upper Louver 5. This fireplace reaches high temperatures. Keep children and Panel Flue Collar adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. Nailing 7. Do not modify this fireplace under any ci
Résumé du contenu de la page N° 4
PRODUCT FEATURES PRE-INSTALLATION PREPARATION 4 Location and Space Requirements PRODUCT FEATURES These are a few facts that can help you understand and enjoy your • Your fireplace is designed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against direct-vent fireplace: any exterior surface on the back, sides, or top of your fireplace, • The venting system may be routed to the outside of your home except where standoff spacers are integrally attached
Résumé du contenu de la page N° 5
PRE-INSTALLATION PREPARATION 5 Clearances 5 Framing and Finishing PRE-INSTALLATION PREPARATION Continued CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: 1 5 D 1 13 /2" B /8" 58 C /2" 21 Back, and sides 0"/mm 5 Perpendicular walls 6" (152mm) 41 A /8" Floor 0"/mm Ceiling to louver opening 42" (1067mm) Front 36" (914mm) 3 E 16 /4" Top 0"/mm F48" Vent (See venting instructions for 1 48 G /4" Nailing Tabs specific venting clearances.) Combustible material with a maxim
Résumé du contenu de la page N° 6
V G G V A D E V B L LOCATION OF TERMINATION CAP 6 LOCATION OF TERMINATION CAP N N H C I B Fixed V V Fixed Closed Openable Closed Openable F B V J G V X B B M A V K X TERMINATION CAP AIR SUPPLY INLET G GAS METER RESTRICTED AREA V X (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (1829mm) [*12 inches (305mm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechan
Résumé du contenu de la page N° 7
VENTING INSTALLATION INSTRUCTIONS 7 Installation Precautions 7 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely be- NOTICE: Failure to follow these instructions will void fore attempting installation. the warranty. These models are tested and approved for use with DESA (direct- INSTALLATION PRECAUTIONS vent) pipe components and terminations. • Wear gloves and safety glasses for protection The venting system must terminate on the outside of the structure and • Use extr
Résumé du contenu de la page N° 8
VENTING INSTALLATION INSTRUCTIONS Installation Planning 8 VENTING INSTALLATION INSTRUCTIONS Continued INSTALLATION PLANNING Female There are two basic types of direct-vent installation: Locking Lugs • Horizontal Termination • Vertical Termination Male Horizontal Termination Installation Slots IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installations using round termi- nation require exterior portion of wall firestop available only in vent Fig
Résumé du contenu de la page N° 9
VENTING INSTALLATION INSTRUCTIONS 9 Installation Planning (Cont.) 9 VENTING INSTALLATION INSTRUCTIONS Continued WARNING: Do not recess vent termination into any wall. This will cause a fire hazard. Cut Siding Away 6. Noncombustible Exterior Wall: Position the horizontal vent to Fit Standoff 1 cap in the center of the 8 /2" round hole and attach to the exte- Standoff rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic Wood
Résumé du contenu de la page N° 10
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 10 VENTING INSTALLATION INSTRUCTIONS Continued 10. Place fireplace into position and shim with noncombustible ma- terial if needed. Nail or screw side flanges to framing to secure WARNING: Never run vent downward as this may unit in place. IMPORTANT: Make sure fireplace is level before cause excessive temperatures which could cause a securing. If fireplace is not level it will not work properly. fire. Operation of improperly install
Résumé du contenu de la page N° 11
VENTING INSTALLATION INSTRUCTIONS 11 Installation Planning (Cont.) 11 VENTING INSTALLATION INSTRUCTIONS Continued Required CORNER INSTALLATION Vertical (V) Vertical Pipe Horizontal (H) 1 Recommended Applications: *46 /4" min. None 30" max. 1 57 /4" min. 1 ft. 48" max. • Corner ground floor installation 1 69 /4" min. 2 ft. 60" max. 1 • Ground floor installation where pipe vents horizontally through wall 81 /4" min. 3 ft. 84" max. 1 (over 12" horizontal pipe) 93 /4" min. 4 ft. 20' max. * Ground Fl
Résumé du contenu de la page N° 12
VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.) 12 VENTING INSTALLATION INSTRUCTIONS Continued HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows. Venting with Two 90° Elbows Horizontal (H ) + 1 Vertical (V) Horizontal (H ) Horizontal (H ) 1 2 45° Elbow 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max. 20' max. 8'
Résumé du contenu de la page N° 13
VENTING INSTALLATION INSTRUCTIONS 13 Installation for Vertical Termination 13 VENTING INSTALLATION INSTRUCTIONS Continued 2. Assemble the desired lengths of pipe and elbows necessary to INSTALLATION FOR VERTICAL TERMINATION reach from the fireplace flue up through the firestop. Be sure Note: Vertical restrictor must be installed in all vertical installations. all pipe and elbow connections are fully twist-locked (see Fig- 1. Determine the route your vertical venting will take. If ceiling ure 8,
Résumé du contenu de la page N° 14
VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.) 14 VENTING INSTALLATION INSTRUCTIONS Continued Venting with One 90° Elbow Vertical Termination Configurations Vertical (V) Horizontal (H) Figures 21 through 24 show four different configurations for verti- 5' min. 2' max. cal termination. 6' min. 4' max. 7' min. 6' max. Venting with Two 90° Elbows 8' min. 8' max. 20' max. 8' max. Vertical (V) Horizontal (H ) + 1 Horizontal (H ) 45° Elbow 2 Note: Install restrict
Résumé du contenu de la page N° 15
VENTING INSTALLATION INSTRUCTIONS 15 Installation for Vertical Termination (Cont.) 15 High Altitude Installation Parts Lists for Venting Kits and Components for V42 and VV42 Series HIGH ALTITUDE INSTALLATION VENTING INSTALLATION Your DESA direct-vent fireplace has been tested and approved for INSTRUCTIONS elevations from 0-2000 feet (USA) and elevations from 0-4500 feet Continued (Canada). When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the i
Résumé du contenu de la page N° 16
VENTING INSTALLATION INSTRUCTIONS Parts Lists for Venting Kits and Components for V42 and VV42 Series (Cont.) 16 Parts Lists for Venting Kits and Components for VV421 Series FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessory 01800 Horizontal Square High Wind Termination (1) VENTING INSTALLATION 01801 14" Snorkel Termination - Galvanized (1) INSTRUCTIONS 01802 36" Snorkel Termination - Galvanized (1) Continued DESA Venting Accessories PARTS LISTS FOR VENTING KITS AND COMPO
Résumé du contenu de la page N° 17
FIREPLACE INSTALLATION 17 Installing Optional Blower Accessory (Cont.) 17 FIREPLACE INSTALLATION Continued 4. Be certain that all wire terminals are securely attached to ter- Speed Control Switch minals on blower motor and that the screw retaining the green Bracket Blower ground wire is tight. Plug-In 5. Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26). Control 6. While supporting speed control, secur
Résumé du contenu de la page N° 18
FIREPLACE INSTALLATION Installing Optional Blower Accessory (Cont.) 18 FIREPLACE INSTALLATION Continued Model BKT Installation Note: When installing the BKT thermostatically-controlled blower, 5. Mount the speed control box against the mounting plate pro- you must first secure the thermal switch bracket to the blower if it vided in the lower fireplace cavity by placing the plastic control has not already been factory installed. shaft forward through the round hole (see Figure 26, page 17). 1. P
Résumé du contenu de la page N° 19
FIREPLACE INSTALLATION 19 Installing Gas Piping to Fireplace Location 19 FIREPLACE INSTALLATION Continued INSTALLING GAS PIPING TO FIREPLACE CAUTION: Use only new, black iron or steel pipe. LOCATION Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" WARNING: A qualified service person must con- inside diameter or greater to allow proper gas volume nect fireplace to gas supply. Follow all local codes. to fireplace. If pipe is too small, undu
Résumé du contenu de la page N° 20
FIREPLACE INSTALLATION Connecting Fireplace To Gas Supply 20 Checking Gas Connections FIREPLACE INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY 4. Check all joints of gas supply piping system. Apply noncorro- Installation Items Needed sive leak detection fluid to all joints. Bubbles forming show a • 5/16" hex socket wrench or nut-driver leak. Correct all leaks at once. • sealant (resistant to propane/LP gas, not provided) 5. Reconnect fireplace and equipment shutoff valve to gas sup- p