CHARNWOOD
SLX20 Multi-Fuel
Roomheater
Operating
and
Installation Instructions
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: +44(0)1983 537799 Fax: +44(0)1983 537788
E-Mail: charnwood@ajwells.co.uk Internet: www.charnwood.com
Résumé du contenu de la page N° 2
CHARNWOOD SLX20 Operating and Installation Instructions Contents Operating Instructions General Points...................3 Fuels..........................3 Door Operation.................4 Multifuel Grate ..................4 Lighting........................3 Controlling The Fire ..............4 Running With The Doors Open.....4 Ash Clearance...................4 Riddling........................5 Refuelling ......................5 Overnight Burning................5 Throat Plate and Flueway Cleanin
Résumé du contenu de la page N° 3
OPERATING INSTRUCTIONS FOR THE CHARNWOOD SLX20 GENERAL POINTS PETROLEUM COKE IS NOT SUITABLE FOR USE ON Before lighting the fire check with the installer that the work THIS APPLIANCE, ITS USE WILL INVALIDATE THE and checks described in the installation instructions have GUARANTEE been carried out correctly and that the chimney has been swept, is sound, and free of any obstructions. At first you may find it helpful to try several fuels to find the WARNING There must not be an extractor fan fitted
Résumé du contenu de la page N° 4
DOOR OPERATION The doors are opened by raising the door handle as shown in Fig. 1.Whenthefireisalight,avoidtouchingthedoors other than on the knobs as the metal will become hot. When closing the doors do not use excessive force. MULTIFUEL GRATE Your Charnwood is fitted witha multifuel grate which enables solid fuel, wood and peat to be burned equally effectively. The grate has two positions. One for solid fuel, the other for wood and peat.When in the solid fuel position ash can fall through the
Résumé du contenu de la page N° 5
THROAT PLATE AND FLUEWAY To make ash removal easier there isa special Charnwood CLEANING ash carrier available. This may be purchased from you supplier or, in case of difficulty, from ourselves. It is important that the throat plate and all the appliance RIDDLING flueways are kept clean. When burning smokeless fuels they should be cleaned at least monthly. When burning other Riddling twicea day is usually sufficient. fuels they should be cleaned oncea week, and more frequently if found necessary
Résumé du contenu de la page N° 6
When not in use b) the thermostat knob is turned down to the minimum setting and the airwash is closed, If the fire is going to be out of use fora long period, (for c) the air inlet damper is closed (at the bottom left of the instance in the summer,) then to prevent condensation, and appliance, see Fig. 1.) and that it is not prevented from hence corrosion, the thermostat should be left at the closing completely bya piece of ash, maximum setting and the main doors left ajar. It is also d)a suita
Résumé du contenu de la page N° 7
glass clean, therefore, when lighting the stove allow the It is always more difficult to keep the glass clean when firebed to become well established before turning the running the stove very slowly for long periods. thermostat down. It may sometimes be beneficial to also keep the doors slightly ajar whilst the fire becomes If blackening of the glass still occurs check that all flue established. This can also apply when re-fuelling. connections are well sealed. It is also important that the b) W
Résumé du contenu de la page N° 8
INSTALLATION INSTRUCTIONS FOR THE CHARNWOOD SLX20 checked, it must be in good condition, free from cracks and HEALTH AND SAFETY blockages, and should not havea excessive cross sectional PRECAUTIONS area (e.g. Greater than 250mmx 250mm). If you find that the chimney is in poor condition then expert advice should WARNING please take care when installing the appliance be sought regarding the necessity of having the chimney that the requirements of the Health and Safety at Work Act lined. If it foun
Résumé du contenu de la page N° 9
the open vent. The shaded area on the face of If an indirect cylinder is used then the primary circuit should the surround is the minimum flat be filled witha suitable inhibitor to prevent the build up of area required. scale and corrosion. 750 mm FITTING THE OPTIONAL ADD-IN B 660 mm A BOILER The boiler replaces the rear firebrick and is reversible so Dim. A: that the 1” B.S.P. male tappings may come on either the left Max. 470mm (18 1/2") Min. 405mm (16") or the right hand side of the boiler. D
Résumé du contenu de la page N° 10
Replace the back fireplate, the side fireplates, the front firebar and the throat plate. Flaunching Connect the boiler to the heating system ensuring that the Take Flue Pipe flow pipe rises from the boiler. Fill the system with water Up To Narrowest and check for leaks. Part Of Chimney. FLUE CONNECTION 150° Elbow Part No. 010/AV12 AND INFILLING Make the flue connection with the special 150° elbow, Part No. 010/AV12. Please note that this item is ordered Vermiculite separately from the appliance.
Résumé du contenu de la page N° 11
ASSEMBLY Fit the side panels and the hood onto the appliance. Instructions for this are enclosed with the panel pack. Replace any internal parts previously removed. PRE LIGHTING CHECK Before initial lighting check the following points: 1. The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated. 2. The plates round the sides and back of the grate must be in position and sitting correctly. 3. The throat plate must be fitted in the roof of