Résumé du contenu de la page N° 1
Select Sensor Channel ........................................ 10
CONTENTS
Minimum / Maximum Records ............................. 11
Contents ................................................................... 1
Temperature Trend .............................................. 11
Introduction .............................................................. 2
Reset System ......................................................... 11
About Oregon Scientific ..........................................
Résumé du contenu de la page N° 2
INTRODUCTION ABOUT OREGON SCIENTIFIC TM Thank you for selecting the Oregon Scientific Wireless Visit our website (www.oregonscientific.com) to learn Thermo Clock (RAR186). This device bundles precise time more about other Oregon Scientific products such as keeping, alarm, and temperature monitoring features into a digital cameras, hand-held organizers, health and fitness single tool you can use from the convenience of your home. gear, and projection clocks. The website also includes contact info
Résumé du contenu de la page N° 3
PRODUCT OVERVIEW FRONT VIEW 1. Sensor Temperature Area: Readings, trend line, sensor reception status and channel number TEMP 1 2. Indoor Temperature Area: Readings, and indoor symbol 2 3. Clock Area: Time display with seconds or days of the week 3 4. Calendar / Alarm Area: Date display and dual alarm 4 display 5. ((.)): Press to view dual alarm settings MODE MEM CHANNEL 6. CHANNEL: Press to switch remote sensor 5 6 7. MEM: Press to view current or saved max / min temperature 7 8 8. MODE: Press
Résumé du contenu de la page N° 4
1. Wall mount 2. °C / °F Switch 3. Alarm (On / Off) 1 4. Press (up button) to increase or (down button) to decrease settings 2 3 5. Battery compartment 4 6. Catch to open battery compartment 7. Table stand 5 REMOTE SENSOR (THN122) 6 4 EN
Résumé du contenu de la page N° 5
GETTING STARTED 1 1 2 3 4 1. LED Status indicator 1. Wall mount hole 2. RESET 3. Channel number (1 - 3) 4. Battery compartment (Battery compartment cover not shown) 5 EN
Résumé du contenu de la page N° 6
BATTERIES on a wall with a nail. Batteries are not supplied with this product. You will need to purchase 2 x UM-3 (AA) 1.5V alkaline batteries for the main unit, and 2 x UM-4 (AAA) 1.5V alkaline batteries for the remote sensor. Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, REMOTE SENSOR (THN122) install batteries in the remote sensor before the main unit. Press RESET after each battery change. This product is shipped with a THN122
Résumé du contenu de la page N° 7
temperature unit before you mount the sensor. small Phillips screwdriver. • Place the sensor out of direct sunlight and moisture. 1. Insert the batteries, matching the polarity as shown • Do not place the sensor more than 30 meters in the battery compartment. (98 feet) from the main (indoor) unit. 2. Set the channel. The switch is located in the battery • Position the sensor so that it faces the main compartment. (indoor) unit, minimizing obstructions such as 3. Place the sensor near the main un
Résumé du contenu de la page N° 8
The reception icon shown in the Temperature Area of week in English, German, Italian, or French. shows the status. SEARCH FOR SENSOR Manually set the clock following the "Set Clock" To search for a sensor, press and hold MEM and instructions (below). ICON DESCRIPTION Main unit is searching for SET CLOCK sensors. 1. Press and hold MODE for 2 seconds. The Clock At least 1 channel has Area will blink. been found. Channel 1 is selected (number 2. Select the hour, minute, date, month, language, day
Résumé du contenu de la page N° 9
information: VIEW ALARM SETTINGS • Current, minimum and maximum readings The Alarm Time and On / Off status will show in the Calendar / Alarm Area. • Trend line for remote sensor Press ((.)) again for the second alarm time and status. Data is collected by the remote sensors and displayed every 30 seconds. SET DUAL ALARM SELECT TEMPERATURE UNIT 1. Press ((.)). Slide the °C / °F switch into the desired location. The 2. Press and hold ((.)) again for 2 seconds. The Alarm switch is located on the ba
Résumé du contenu de la page N° 10
the selected sensor. To clear both the indoor free mild detergent. Avoid dropping the product or placing thermometer and selected sensor records, press and it in a high-traffic location. hold MEM for 2 seconds. A beep will sound to confirm that the memory has been WARNINGS cleared. This product is designed to give you years of service if handled properly. Observe the following guidelines: TEMPERATURE TREND The trend line is shown next to the Temperature reading. • Never immerse the product in wa
Résumé du contenu de la page N° 11
Check here before contacting our customer service L x W x H 92 x 60 x 20 mm department. (3.6 x 2.4 x .79 inches) Weight 2.22 ounces without battery Problem Symptom Remedy TEMPERATURE Calendar Strange date / Change language Unit °C or °F month ( 9) Indoor Range -5 °C to 50 °C Clock Cannot adjust Set Clock (23 °F to 122 °F) clock ( 9) Outdoor Range -20 °C to 60 °C Temp Shows "LLL" Temperature is out-of- (-4 °F to 140 °F) or "HHH" range Resolution 0.1 °C (0.2° F) Remote Cannot locate Check ba
Résumé du contenu de la page N° 12
Calendar DD/MM; weekday in frequency energy and, if not installed and used in 4 languages (E, F, D, I) accordance with the instructions, may cause harmful interference to radio communications. Alarm 2-minute crescendo However, there is no guarantee that interference will not occur in a particular installation. If this equipment does POWER cause harmful interference to radio or television Main unit batteries 2 x UM-3 (AA) 1.5V reception, which can be determined by turning the alkaline equipment o
Résumé du contenu de la page N° 13
Name: Oregon Scientific, Inc. th Address: 19861 SW 95 Place, Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883 Fax No.: 1-503-684-8883 declare that the product Product No.: RAR186 Product Name: Remote Thermo Clock Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interferenc
Résumé du contenu de la page N° 14
Wireless Thermo Clock Model : RAR186 User Manual 14 EN
Résumé du contenu de la page N° 15
© 2004 Oregon Scientific. All rights reserved. P/N.: 086-003372-01 15 EN