KM-151BAH
KM-151BWH
INSTRUCTION MANUAL
L1M006102 (100109)
Résumé du contenu de la page N° 2
IMPORTANT Only qualified service technicians should install, service and maintain the product. No installation, service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the product until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the equipment in accordance with this manual may adversely affect safety, performance, componen
Résumé du contenu de la page N° 3
IMPORTANT 1. This booklet is an integral and essential part of the product and should be handed over to the user. Read the warnings contained in this booklet carefully as they give important indications regarding the safety of the installation, use and maintenance. Please preserve this booklet for any further consultation that may be necessary. 2. This icemaker should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and t
Résumé du contenu de la page N° 4
I. Specifications A. Nameplate Rating Model Amperes Refrigerant ARI Energy Star KM-61BAH 3.4 AMPS R134a 7.1 oz. Not applicable Not applicable KM-101BAH 5.2 AMPS R134a 7.8 oz. Applicable Applicable KM-151BAH 7.0 AMPS R134a 8.5 oz. Applicable Applicable KM-151BWH 7.0 AMPS R134a 10.3 oz. Applicable Not applicable See the Nameplate for electrical and refrigeration specifications. This Nameplate is located on the upper part of the Left Side Panel. We reserve the right to make changes in specifica
Résumé du contenu de la page N° 5
B. Dimensions/Connections 1. KM-61BAH Unit: mm [inches] 2
Résumé du contenu de la page N° 6
2. KM-101BAH Unit: mm [inches] 3
Résumé du contenu de la page N° 7
3. KM-151BAH Unit: mm [inches] 4
Résumé du contenu de la page N° 8
4. KM-151BWH Unit: mm [inches] 5
Résumé du contenu de la page N° 9
II. Installation and Operating Instructions A. Checks Before Installation * Visually inspect the exterior of the shipping container, and any severe damage noted should be reported to the carrier. IMPORTANT 1. Remove shipping carton, tape(s) and packing. If packing material is left in the icemaker, it will not work properly. 2. Ensure all components, fasteners and thumbscrews are securely in place. 3. Remove the shipping tapes holding the Door and Separator. See Fig. 1. 1) Remove the panels t
Résumé du contenu de la page N° 10
Top Panel Separator Storage Bin Top Panel Tab Door (both ends) Control Switch Louver Tab (both ends) Air Filter Condenser Louver Fig. 1 C. Location WARNING This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +32° C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may a
Résumé du contenu de la page N° 11
* The icemaker requires no clearance at either side. But allow enough space at rear for water supply and drain connections, at least 12” (approx. 30 cm) clearance at front, and at least 0.6” (approx. 15 mm) clearance at top for maintenance. D. Electrical Connection WARNING THIS APPLIANCE MUST BE GROUNDED. This icemaker requires a ground that meets the national and local electrical code requirements. To prevent possible severe electrical shock injury to individuals or extensive damage to e
Résumé du contenu de la page N° 12
4) When installing the unit without legs, the perimeter where the machine touches the counter should be sealed with silicone to prevent water from leaking under the icemaker. 5) When installing the unit with legs on the bottom, use the four accessory legs adjustable from 6” (15.2 cm) to 7” (17.8 cm). Screw the legs tightly into the tapped holes in the base (see Fig. 3). Handle the icemaker carefully not to damage the exterior. Tapped Hole (Leg Mounting) Base Adjustable Leg Fig. 2 F
Résumé du contenu de la page N° 13
* Drain lines should not be piped directly KM-61BAH, KM-101BAH, KM-151BAH to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and the floor drain. * This icemaker should be installed in accordance with applicable national, state and local regulations. * A plumbing permit and services of a licensed plumber may be required in some areas. Drain Outlet 3/4” FPT Water Supply Inlet 1/2” FPT Fig. 4 10
Résumé du contenu de la page N° 14
KM-151BWH Bin Drain Outlet Condenser Water 3/4” FPT Outlet 1/2” FPT Condenser Water Inlet 1/2” FPT Icemaking Water Supply Inlet 1/2” FPT Shut-off Valve Two-inch (5 cm) air gap Drain Valve Separate piping to approved drain. Drain Valve Leave a two-inch (5 cm) vertical air gap between the end of each pipe Shut-off Valve and the drain. Floor Drain Fig. 5 11
Résumé du contenu de la page N° 15
G. Final Checklist 1) Is the icemaker level? 2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7° C to +38°C) and the water temperature within +45°F to +90°F (+7°C to +32°C) all year around? 3) Is there at least 0.6” (15 mm) clearance at top of the icemaker for ease of maintenance or service? 4) Have all shipping carton, tape(s) and packing been removed from the icemaker? Is the cube guide in its correct position? 5) Are all components, fasteners and scre
Résumé du contenu de la page N° 16
H. Startup CAUTION 1. All parts are factory-adjusted. Improper adjustments may result in failure. 2. If the unit is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the Compressor. * Check that shipping tape(s), string and packing are removed before starting the icemaker. 1) Open the Water Supply Line Shut-off Valve. 2) Remove the Air Filter. 3) Move the Control Switch on the Control Box to the “ICE” position. 4) Let the icemaker run for 10 minutes, t
Résumé du contenu de la page N° 17
III. Cleaning and Maintenance Instructions IMPORTANT Ensure all components, fasteners and screws are securely in place after any maintenance or cleaning is done to the equipment. A. Cleaning WARNING 1. Hoshizaki recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions. 2. To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners. 3. Always wear liquid-proof gloves to prevent the
Résumé du contenu de la page N° 18
7) Same as step 4. 8) Move the Control Switch to the “ICE” position to fill the Water Tank with water. 9) After 3 minutes, move the Control Switch to the “WASH” position. 10) After 5 minutes, move the Control Switch to the “OFF” position. 11) Same as step 4. 12) Repeat steps 8 through 11 three more times to rinse thoroughly. 13) Disconnect the Silicone Hose and Overflow Pipe. Next, remove the Water Tank by pressing down on the snaps on the Bracket (L) (R) and pulling the tank towards you slight
Résumé du contenu de la page N° 19
Cube Guide Water Tank Snap * This illustration shows KM-61BAH. The following number of Cube Guides are provided: KM-61BAH 2 pcs KM-101BAH 3 pcs KM-151BAH 3 pcs KM-151BWH 3 pcs * The Bin Control Switch is accessible by removing the Water Tank. Pull the switch towards you for easy maintenance. * This is the front view with the Door opened and the Water Tank removed. Bin Control Switch Fig. 8 16) Wash the Bin Control Switch, Water Tank, Float Switch, Cube Guide, Silicone Hose and Ov
Résumé du contenu de la page N° 20
3) Discard the sanitizing solution and rinse the parts thoroughly with water. 4) Replace the removed parts in their correct positions in the reverse order of which they were removed. 5) Same as step 1. 6) Pour the sanitizing solution into the Water Tank, and allow the sanitizer to sit for 10 minutes. 7) Move the Control Switch to the “WASH” position. Close the Door. 8) After 15 minutes, move the Control Switch to the “OFF” position. Open the Door. 9) Disconnect the Silicone Hose to drain the