Résumé du contenu de la page N° 1
®
INSTALL GUIDE
CLEAR ICE MODELS
CLEAR ICE COMBO MODELS
ICE COMBO MODELS
CO2175
CLRCO2175
CO1175 CO29
CLR2160
The Built-In Undercounter Leader Since 1962 U-LINE.COM
Résumé du contenu de la page N° 2
1 Table of Contents Safety Precautions Safety Alert Definitions.........................................................................................................................................1 General Precautions..............................................................................................................................................1 Inspect & Plan Product Registration ...................................................................................................
Résumé du contenu de la page N° 3
2 Safety Precautions General Precautions Use this appliance for its intended purpose only and follow these IMPO IMPOR RT TANT ANT general precautions with those listed throughout this guide: • PLEASE READ all instructions before installing, operating, or servicing the appliance. DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your • Proper installation procedures must be followed when old refrigerator or freezer, take off the doors and leave shelves completing an installation or relo
Résumé du contenu de la page N° 4
Tools / Material Required 3 Inspect & Plan • Screwdrivers — slotted and Phillips head • 1/4-inch thick door panel material and cutting tools (If installing a 1/4” Panel) • 1/4” Nut Driver • 5/16” Nut Driver Product Registration • Side Cutter You have received a carton containing your U-Line Clear Ice, Ice or • Copper tubing cutter Ice Combo unit with a package inside containing a Use and Care Guide, a Product Registration Card, and a water line kit. Please • 12” Level complete and mail the P
Résumé du contenu de la page N° 5
4 Prepare Site Your U-Line product has been designed for either free-standing or CO29 Series built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front Filler Panel (Not Provided by U-Line) – May Be Added Above or Below Unit grille must NOT be obstructed and clearance is required for an to Enclose for a Built-In Look electrical connection in the rear. IMPO IMPOR RT TANT ANT • Unit can NOT be installed behind a closed cab
Résumé du contenu de la page N° 6
5 Product Dimensions All Models CLR2160 Series CO1175 Series CO29 Series 23” * 23-3/16" * 23-1/16”* 28-1/2" 34-1/8" 34-1/8" 4-3/4” 3-15/16” 15" 3-1/2” 20-13/16" 23-15/16”" STAINLESS CO1175 Black and White *Add 15/16” To Depth For Water Line Clearance *Add 3/16” to Depth For Water Line Clearance *Add 3/4” To Depth For Drain Line Clearance 23-1/8” * CO2175 Series CLRCO2175 Series 23”* 23” 34-1/8" 34-1/8” 34-1//8" 3-7/8” 15" 3-13/16” 24" Stainless Steel 3-13/16” 24" *Add 3/4” To Depth For Drain
Résumé du contenu de la page N° 7
CO29 6 Door Swing Dimensions 1/4" Min. All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 2” to accommodate the handle if the unit is installed next to a wall. 21-7/16" CLR2160 Wall Wall 1/4" Min. 2-1/8" Min. 22-3/8" 90° Door Swing 21-3/4" 21-3/4" Other Site Requirements Side-By-Side Installation 16-1/2" 16-1/2" 90 90 For a complete refreshment center, install two units side by side: Door Swing Door Swing Cut-out width for a side-by-side i
Résumé du contenu de la page N° 8
To reverse the door: 7 Standard Doors Remove grille: Remove the grille see MAINTENANCE section of this guide. Door Alignment and Adjustment Align and adjust the door if it is not level, or is not sealing properly. If the door is not sealed the unit may not cool properly, or excessive frost may form in the interior. IMPO IMPOR RT TANT ANT Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket
Résumé du contenu de la page N° 9
1 Install bottom hinge: Prepare door for reinstallation: 1. If you have a plate hinge, reorient the pivot screw so it protrudes the opposite direction form the hinge. Remove the For black or white doors: pivot screw from the hinge. Turn the plate over and reinstall 1. Remove plastic hole plug from top of door handle and reinstall the screw. on opposite side. 2. Align hinge outer edge with cabinet. For models with a plate 2. Remove plastic hinge bushing on bottom of door and reinstall on hi
Résumé du contenu de la page N° 10
8 Self-Closing Doors Door Alignment and Adjustment Align and adjust the door if it is not level, or is not sealing properly. If the door is not sealed the unit may not cool properly, or excessive frost may form in the interior. IMPO IMPOR RT TANT ANT • Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door 4 (no gaps). Carefully examine the door’s gasket to ensure that it is firmly in contact with the cabinet. Also 5. After adjustment i
Résumé du contenu de la page N° 11
To reverse the door: Remove existing bottom hinge. Remove the existing bottom hinge (three screws) (2). Reinstall hinge to top opposite. 3 1 Install the hinge just removed from the bottom to the TOP opposite side of the cabinet (three screws) (2). Reinstall Hole Plugs. Install plastic screw plugs (three each, top and bottom) (3) into holes where hinge hardware was removed. 2 Remove door: 1 1. Hold door to keep it from falling. 2. Remove hinge screw pin (1) from top hinge using a Phillips scre
Résumé du contenu de la page N° 12
3. Remove the two outside screws holding 9 Door Panel Installation door handle. Slightly separate door handle from door. Custom 1/4'' Thick Door Panel Insert 4. Pull handle up and off. Door Panel Preparation 5. Slide custom door panel insert into 1/4- A custom door panel may be inserted into the doorframe. Custom inch channel in door front. door panels can be flat or raised, as long as the maximum panel thickness, where inserted into the door reveal (channel), is no IMPO IMPOR RT TANT ANT mo
Résumé du contenu de la page N° 13
CO1175 10 Prepare Power Supply Electrical Specifications WARNING SHOCK HAZARD — Electrical Grounding Required. 24" • Never remove the round grounding prong from the 7" plug and never use a two-prong grounding adapter. 4" • Never use an extension cord to connect power to the unit. CO29 IMPO IMPOR RT TANT ANT Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified elect
Résumé du contenu de la page N° 14
P Drain Connection (CLR2160 CLRCO2175) 11 Prepare Plumbing IMPO IMPOR RT TANT ANT • Drain can NOT be located directly below unit. Unit has CAUTION a solid base that will not allow the unit to drain below itself. Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by • We strongly recommend the use of a U-Line drain kit a licensed/qualified plumbing contractor. Failure to follow for both gravity & pump installations. A complete drain r
Résumé du contenu de la page N° 15
To check and test hose connections: Factory-Installed Drain Pump 1. Make certain the unit is not plugged into an electrical outlet. If your drain line will run up to a stand pipe, disposal or spigot assembly, or does not otherwise meet the requirements for a 2. Carefully push the power cord grommet through the hole in the Gravity Drain, you may have ordered the CLR2160 or back panel. CLRCO2175 with a U-Line P60 Drain Pump. See Below for typical 3. Remove 12 screws and back panel. installati
Résumé du contenu de la page N° 16
To connect to drain: Final Water Connection: 1. Connect the water supply fitting by screwing the brass garden WARNING hose fitting to the water valve in the rear of the unit. To prevent accidental electrocution, make certain that 2. Tighten this fitting with pliers. the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to, the IMPO IMPOR RT TANT ANT unit. Do not use Teflon tape or joint compound on this fitting. Drain Fitting from 1. Slide 2 hose clamps
Résumé du contenu de la page N° 17
12 Level The Unit 13 Install the Unit Installation Leveling Information 1. Open the water supply valve in the main water source. It is recommended that the unit is level. 2. Plug in the power cord. 1. Use a level to check the levelness of the CLR2160 & CLRCO2175 Only unit from front to • Open the door and press the POWER icon. to turn the unit back and from side OFF. to side. Level should be placed along top Note: If the unit is NOT turned OFF, water will immediately edge and side edge
Résumé du contenu de la page N° 18
Installation Troubleshooting Problem Q: Water is leaking under the unit. Solution A: A water leak under the unit is most likely caused by a bad connection in the water supply line. Make sure the water line’s brass fitting is screwed tight to its valve and threaded correctly. Problem Q: The door remains open unless it is pushed closed. Solution A: The hinges should be self-closing when the door is open approximately 8". If this is not the case, make sure the closers (at the bottom of the hin
Résumé du contenu de la page N° 19
® INSTALLATION GUIDE SERVICE INFORMATION If you have a problem with this appliance, your use and care guide has troubleshooting information to help you quickly identify common problems and provide information on possible cause and remedy. Answers to Customers Frequently Asked Questions are available at www.u-line.com/customer/faq.cfm. You may contact U-Line directly: GENERAL INQUIRIES: SERVICE ASSISTANCE: U-Line Corporation Phone (800) 779-2547 P.O. Box 245040 FAX (414) 354-5696 Milwaukee,