OPERATION MANUAL
FTB-350A 24V TEST BOX
Frymaster, L.L.C., 8700 Line Avenue
Shreveport, LA 71106
TEL 318-865-1711 FAX 318-868-5987
24-Hour Service Hotline
1-800-551-8633
APRIL 11
*8196797*
Résumé du contenu de la page N° 2
TABLE OF CONTENTS Page # INTRODUCTION 3 PARTS ORDERING 3 PARTS LIST 4 CONTROL PANEL DIAGRAM 5 F3000 TEST PROCEDURE Legacy Fryers 6 F3000 TEST PROCEDURE HP580/590 Electric 8 F3000 TEST PROCEDURE HP690 Gas 9 F3000 TEST PROCEDURE Pitco Fryers 12 2
Résumé du contenu de la page N° 3
INTRODUCTION The FTB-350A Test Box is a tester designed to test the F3000 Frymaster cooking controller for correct operating and controlling functions. WARNING: This test box should not be hooked up to 12V controllers. PARTS ORDERING Parts orders must be placed directly with your local Factory Authorized Servicer. If you do not have a Factory Authorized Servicer list, please contact Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711. To speed up your order, the fo
Résumé du contenu de la page N° 4
1 2 3 PARTS LIST Item Part Number Description Kit, FTB350A, 120V/24V F3000 Test Box (Includes cable and 826-2978 transformer assembly.) 1 108-3342 Test Box FTB-350A 120V/24V Domestic 2 108-3345 Transformer Assembly 120V/24V Domestic 3 807-5285 Cable Assembly, F3000 Cable 4
Résumé du contenu de la page N° 5
TOP CONTROL PANEL 1. Stratify Indicator 7. Right Probe/Thermistor Switch On during stratify on HP Simulates Temperature fryers. 2. Left Heat Indicator 8. Left Variable Control ON When Heating 3. Power On Indicator 9. Right Variable Control Power to Fryer Relays & Controller 4. Right Heat Indicator 10. ON/OFF Switch ON When Heating Power To FTB-350A Test Unit 5. Pressure Solenoid Indicator 11. HP690 Power Switch On when pressure solenoid Power to FTB-350A Test Unit and is act
Résumé du contenu de la page N° 6
F3000 TEST PROCEDURE FOR LEGACY FRYMASTER FRYERS (KJ3, 118G, H55, MJ45, 118E/RE80 and FPRE114/117) Ensure the controller is set to LEGACY-FRYMASTER using code 7628 in tech mode. With the Controller displaying OFF press and hold the check button until PRODUCT SETUP is displayed. Press the right arrow to tech mode. Enter 7628. Set LOCALE to NON-CE. Press the right arrow. Set system type to LEGACY-FRYMASTER. Press the right arrow. Set ENERGY to ELEC or GAS. Press the right arrow. Set
Résumé du contenu de la page N° 7
D. TEST CONTROLLING FUNCTION 1. Press controller ON/OFF switch to ON (set point = 340°F/171°C). 2. Set FTB-350A PROBE switches (6 & 7) to VARIABLE. (a) RELAY POWER indicator (3) illuminates. (b) Rotate VARIABLE knob (8 & 9) counterclockwise until controller indicates a temperature. (c) Rotate VARIABLE knob (8 & 9) slowly clockwise until controller indicates DROP. (d) Press Temperature button on controller. Controller should indicate a temperature from one (1) to (4) degrees +/- set p
Résumé du contenu de la page N° 8
F3000 TEST PROCEDURE FOR HENNY PENNY PRESSURE FRYERS (HP580 and HP590) Ensure the controller is set to HENNY PENNY 580/590/290 FULL using code 7628 in tech mode. Press and hold the check button until PRODUCT SETUP is displayed. Press the right arrow to tech mode. Enter 7628. Set LOCALE to NON-CE. Press the right arrow. Set system type to HENNY PENNY. Press the right arrow. Set ENERGY to ELEC. Press the right arrow. Set TYPE to HP580/590. Press the right arrow. Set FRESH OIL to NO
Résumé du contenu de la page N° 9
n) Leave 2 FLEX at 0. Press the right ( ) arrow. o) Leave 2 PRESSURE SOLENOID to OPEN. Press the right ( ) arrow. p) Leave :00 at 3 TIME. Press the right ( ) arrow. q) Leave 1 ALARM TIME at :00. Press the right ( ) arrow. r) Leave AFTER COOKING to COOL. Press the right ( ) arrow. s) Leave FILTER LOCKOUT to 0. Press the right ( ) arrow. t) Leave QUANTITY? to NO. Press the right ( ) arrow. u) Leave HEAD COUNT to .0. Press the right ( ) arrow. v) Leave INSTANT ON to 0. Press the r
Résumé du contenu de la page N° 10
B. TEST POWER TO FRYER INTERFACE BOARD 1. Switch the HP690 POWER switch (11) to ON. 2. RELAY POWER indicator (3) should illuminate. 3. Turn power off switching the HP690 POWER switch (11) to OFF. C. TEST MELT-CYCLE FUNCTION 1. Switch the HP690 POWER switch (11) to ON. 2. Set FTB-350A PROBE switch (7) to 3°C/37°F. (a) RELAY POWER indicator (3) illuminates. (b) HEAT indicator (4) should cycle on and off. “MLT-CYCL” is displayed on the controllers alternating with setpoint on the l
Résumé du contenu de la page N° 11
F. TEST PROBE FAILURE MALFUNCTION 1. Turn on FTB-350A POWER switch (10). 2. Set FTB-350A PROBE switch (7) to SHORT. (a) RELAY POWER indicator (3) illuminates. (b) Controller displays “HIGH LIMIT FAILURE” alternating with “DISCONNECT POWER” and the alarm sounding. (c) RELAY POWER indicator (3) is no longer illuminated. (d) Turn off FTB-350A POWER switch (10). G. TEST ALARM FUNCTION 1. Turn on FTB-350A POWER switch (10). 2. Set FTB-350A PROBE switch (7) to 168°C/335°F. 3. Set
Résumé du contenu de la page N° 12
F3000 TEST PROCEDURE FOR PITCO FRYERS (18WKS FULL, SG18 FULL, SSH75 FULL, SG6H FULL, 14WKS FULL, 7WKS FULL, 7- 2WKS SPLIT, E18WKS FULL, SE18 17 KW FULL and SE 22KW FULL) Ensure the controller is set to PITCO using code 7628 in tech mode. With the Controller displaying OFF press and hold the check button until PRODUCT SETUP is displayed. Press the right arrow to tech mode. Enter 7628. Set LOCALE to NON-CE. Press the right arrow. Set system type to PITCO. Press the right arrow. Set ENE
Résumé du contenu de la page N° 13
THIS PAGE INTENTIONALLY LEFT BLANK
Résumé du contenu de la page N° 14
Frymaster, L.L.C Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135 SERVICE HOTLINE 819-6797 PRINTED IN THE UNITED STATES APRIL 11 1-800-551-8633