Résumé du contenu de la page N° 1
ADCP-80-412 x Issue 1 x April 2000
DSX Bay Tracer Illuminator
User Manual
13914-B
Content Page
INTRODUCTION .......................................................................... 1
Revision History..................................................................... 2
Trademark Information ................................................................ 2
Admonishments ..................................................................... 2
Certification.......................................
Résumé du contenu de la page N° 2
ADCP-80-412 x Issue 1 x April 2000 An LED mounted on the Bay Tracer Electronic Sensor Device provides a large, bright, easily observable, visual indication whenever an individual jack LED is activated on a DSX bay. This allows a technician to identify the far end bay so that a scan can be performed to identify the specific jack LED that has been activated. The indicator flashes for a nominal period of 70–90 seconds following jack activation to allow sufficient time to scan a 6 u 25 bay environme
Résumé du contenu de la page N° 3
ADCP-80-412 x Issue 1 x April 2000 1 PRODUCT DESCRIPTION Electronic circuitry in the Bay Tracer sensor checks for a change in current on one or more –48 Vdc power conductors on the DSX-1 or DSX-3 fuse panel caused by an individual jack insertion on the far end bay and uses this change to activate an LED. The change in current is detected by a clamp-on inductive pick-up coil encircling the –48 Vdc power conductor(s) attached to the DSX fuse panel of the device being monitored. A two-conductor 8-f
Résumé du contenu de la page N° 4
ADCP-80-412 x Issue 1 x April 2000 FILLER FILLER BLANK PANEL (FRONT) PANEL PANEL CABLE TROUGH (REAR) FUSE PANEL RESERVED FOR MISCELLANEOUS APPLICATIONS RESERVED FOR MISCELLANEOUS APPLICATIONS DSX PANEL DSX PANEL 14093-A NOTE: SENSOR AND POWER ATTACHMENT POSITION AND APPEARANCE SHOWN EXAGGERATED FOR CLARITY. Figure 1. Bay Tracer Cable Routing 1. Attach the Bay Tracer Electronic Sensor Device mounting bracket to the top cross member or vertical support flange of the DSX-1 or DSX-3 bay using two pr
Résumé du contenu de la page N° 5
ADCP-80-412 x Issue 1 x April 2000 a. Unsnap the top bar of the inductive pick-up coil. Insert the main DSX-1 or DSX-3 –48 Vdc power conductor into the inductive pick-up coil as shown in Figure 3, making sure that the label side of the coil faces toward the power source. Snap the top bar back into place after inserting the power feed wire. Anchor the power conductor to the inductive pick-up coil with a tie wrap or lacing cord in accordance with local practice. b. Unsnap the top bar of the induct
Résumé du contenu de la page N° 6
ADCP-80-412 x Issue 1 x April 2000 BAYTRACER POWER ATTACHMENT FILLER PANEL FILLER PANEL UPPER CABLE TROUGH SENSOR —48V ATTACHMENT FUSE PANEL BATTERY RETURN INDUCTION COIL BATTERY RETURN DSX PANEL —48V KEEP NON-DSX EQUIPMENT BATTERY RETURN DSX OUT OF COIL —48V PANEL 14059-A REAR VIEW —48V BATTERY RETURN NOTE: SENSOR AND POWER ATTACHMENT POSITION AND APPEARANCE SHOWN EXAGGERATED FOR CLARITY. Figure 4. Sensor Cabling Option B 4. Attach the trailing wires from the inductive pickup coil to the ADC-pr
Résumé du contenu de la page N° 7
ADCP-80-412 x Issue 1 x April 2000 POWER SENSOR CONNECTOR TOP VIEW CONNECTOR RED FLASHING LED LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW 13928-B Figure 5. Bay Tracer Electronic Sensor Device Connectors 5. Attach the customer-supplied power feed wires for the electronic sensor device to an unused –48 Vdc branch circuit on the DSX-1 or DSX-3 fuse panel as shown in Figures 3 and 4. Attach the opposite ends of these wires to the ADC-provided power connector on the electronic sensor device making sure
Résumé du contenu de la page N° 8
ADCP-80-412 x Issue 1 x April 2000 4 OPERATIONAL CONSIDERATIONS The electronic sensor device LED may be falsely activated by external EMI emitted by power drills, wire wrap guns, or other AC powered devices located within 12 inches of the inductive pick-up coil. If such a condition occurs, the electronic sensor device automatically resets after the change in current state and returns to a constant dc state. 5 TROUBLESHOOTING The LED on the bay tracer electronic sensor device is designed to light
Résumé du contenu de la page N° 9
ADCP-80-412 x Issue 1 x April 2000 6 CUSTOMER INFORMATION AND ASSISTANCE For customers wanting information on ADC products or help in using them, ADC offers the services listed below. To obtain any of these services by telephone, first dial the central ADC telephone number, then dial the extension provided below. The central number for calls originating in the U.S.A. or Canada is 1-800-366-3891. For calls originating outside the U.S.A. or Canada, dial country code “1” then dial 952-946-3000. Sal
Résumé du contenu de la page N° 10