Résumé du contenu de la page N° 1
TDD-D-1
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
Résumé du contenu de la page N° 2
General Features NATURAL GAS MODELS AIR DELIVERY Central heating furnace designs are The variable speed, direct drive blower certified by the International Approval motor, has sufficient airflow for most Services (IAS) for both natural and heating and cooling requirements, will L.P. gas. Limit setting and rating data switch from heating to cooling speeds on were established and approved under demand from room thermostat. The standard rating conditions using blower door safety switch will prevent
Résumé du contenu de la page N° 3
Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V Performance Data 7 Electrical Data 11 Field Wiring 12 Dimensions 15 Pub. No. 22-1682-05-0802 (EN) 3
Résumé du contenu de la page N° 4
Features and Benefits XV 90 STANDARD EQUIPMENT HInged blower door Variable speed indoor blower Perfect fit door latches Silicon Nitride Igniter with adaptive Insulated blower door heat up Gasketed blower door Variable speed induced draft blower Internal filter rack Direct/Non-Direct vent option Standard filter sizes Fused 24 volt control circuit Two tone color Manual reset burner safety switches Complete front service access Power supply 115/1/60 Left/right gas co
Résumé du contenu de la page N° 5
Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ............................................................................
Résumé du contenu de la page N° 6
General Data TUY-R9V PRODUCT SPECIFICATIONS1 MODEL TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V RATINGS2 1st Stage Input BTUH 39000 52000 65000 78000 3 1st Stage Capacity BTUH (ICS) 37000 49000 62000 74000 2nd Stage Input BTUH 60000 80000 100000 120000 2nd Stage Capacity BTUH (ICS)3 56000 73000 93000 112000 AFUE (ICS) 93.0 92.5 93.0 92.5 Temp. Rise (Min.-Max.) °F. 35 - 65 35 - 65 35 - 65 40 - 70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Dia.-Width (In.) 10 x 8 10 x 8 10 x 10 10 x 10 No. Used 1
Résumé du contenu de la page N° 7
Performance Data *UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW UNIT SIZE SETTING (TONS) SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW CFM 575 575 575 550 ON ON OFF ON - (350 CFM/TON) WATTS 65 90 125 155 NORMAL CFM 640 640 640 630 1.5 ON ON OFF OFF - (400 CFM/TON) WATTS 70 110 140 175 HIGH CFM 700 700 700 700 ON ON ON OFF - (450 CFM/TON) WATTS 85 125 160 200 LOW CFM 700 700 700 700 OFF
Résumé du contenu de la page N° 8
Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) (See Notes) SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW CFM 750 750 750 720 710 ON ON OFF ON (350 CFM/TON) WATTS 84 122 154 185 221 NORMAL CFM 840 840 840 840 820 2.0 ON ON OFF OFF (400 CFM/TON) WATTS 109 146 181 226 264 HIGH CFM 940 940 940 940 940 ON ON ON OFF (450 CFM/TON) WATTS 136 177 215 27
Résumé du contenu de la page N° 9
Performance Data TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW CFM 1040 1040 1040 1030 1030 ON ON OFF ON (350 CFM/TON) WATTS 165 220 270 320 375 NORMAL CFM 1210 1210 1230 1230 1230 3.0 ON ON OFF OFF (400 CFM/TON) WATTS 235 285 360 415 475 HIGH CFM 1340 1370 1400 1390 1370 ON ON ON OFF (450 CFM/TON) WATT
Résumé du contenu de la page N° 10
Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW CFM 1210 1210 1220 1230 1230 OFF ON OFF ON (350 CFM/TON) WATTS 220 270 325 400 445 NORMAL CFM 1400 1440 1450 1450 1410 3.5 OFF ON OFF OFF (400 CFM/TON) WATTS 305 390 465 510 560 HIGH CFM 1590 1600 1610 1600 1380 OFF ON ON OFF (450 CFM/TON) W
Résumé du contenu de la page N° 11
Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TUY060,080,100,120R9V-V LEGEND From Dwg. 21D341111 P03 Pub. No. 22-1682-05-0802 (EN) 11
Résumé du contenu de la page N° 12
Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341127 Rev. 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341126 Rev. 0 12 Pub. No. 22-1682-05-0802 (EN)
Résumé du contenu de la page N° 13
Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341125 Rev. 1 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341124 Rev. 1 Pub. No. 22-1682-05-0802 (EN) 13
Résumé du contenu de la page N° 14
Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341128 Rev. 0 14 Pub. No. 22-1682-05-0802 (EN)
Résumé du contenu de la page N° 15
Dimensions Pub. No. 22-1682-05-0802 (EN) 15 TUY-R9V-V OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES)
Résumé du contenu de la page N° 16
File No. PL-UN-FURN-TDD-D-1 3/98 P.I. Supersedes TDD-D-1 8/95 Trane A business of American Standard Companies Since Trane has a policy of continuous product improvement, it reserves the right to change design and www.trane.com specifications without notice.