Résumé du contenu de la page N° 1
This system uses
R-410A
M00036-V00
Résumé du contenu de la page N° 2
IMPORTANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: • Carefully read this instruction booklet before beginning. • Follow each installation or repair step exactly as shown. • Observe all local, state, and national electric codes. • Pay
Résumé du contenu de la page N° 3
CONTENTS Safety considerations 1 Accessories 2 Installation recommendations (indoor unit) 3 Installation recommendations (outdoor unit) 4 Electrical installation 5 Wiring system diagram 6_7 Electrical connections for indoor and outdoor units 8 Refrigerant line connections 9 Refrigerant R410A: special precautions when installing unit 10 Tightening refrigerant piping connections 11 System evacuation 12 Additional charge 13 Gas leak check 14 Checking and testing operation 15 Technical specification
Résumé du contenu de la page N° 4
SAFETY CONSIDERATIONS This manual is a guide for properly installing the Williamson-Thermoflo Wall-mounted split air conditioner. Improper installation can result in unsafe and dangerous conditions that will void the factory warranty. Prior to installation, read these instructions and any instructions that are packaged with separate pieces of equipment that make up the system. Please read these instructions thoroughly and carefully before attempting installation or operation. Failure to follow t
Résumé du contenu de la page N° 5
ACCESSORIES The following accessories are supplied with the air conditioner. • The quantities are indicated in parenthesi s. Accessories in the Indoor Unit Case “AAA” batteries for Remote control Installation plate (1) Remote control (1) remote control (2) holder (1) Owner’s manual (1) Installation manual (1) Service manual (1) Warranty (1) Interconnecting wiring and conduits from the outdoor unit to the indoor unit are not provided with the air conditioner. Accessories in the Outdoor Unit Case
Résumé du contenu de la page N° 6
INSTALLATION RECOMMENDATIONS (INDOOR UNIT) 3 1. Before fixing the installation plate to a wall, you must determine the position of the 2 /4 in (70 mm) hole through which the conduit, piping and drain hose pass to connect the indoor unit to the outdoor unit. The piping and conduit can be con- nected from the: Rear, Right or Left side of indoor unit. INCORRECT CORRECT 2. Determine the position of the pipe and drain hose hole using one of the figures shown, and drill the hole with an inner 3 diamet
Résumé du contenu de la page N° 7
INSTALLATION RECOMMENDATIONS (OUTDOOR UNIT) Attach the outdoor unit with 4 anchor bolts and nuts (not supplied) positioned as per dimensions A, B. 24SRAO-HE 9SRAO-HE 12SRAO-HE | 15SRAO-HE 18SRAO-HE A (in) 21 3/8 25 24 3/8 23 B (in) 13 13 3/8 15 15 A 24 in minimum Air inlet 9 in minimum 12 in minimum Air outlet 24 in minimum 16 in minimum Caution: The outdoor unit should not be exposed to strong winds or where it is very dusty. - Take your neighbors into consideration so that they will not be dis
Résumé du contenu de la page N° 8
ELECTRICAL INSTALLATION 1. The air conditioner shall be installed by a qualified technician in accordance with national and local electrical codes. 2. A disconnect switch shall be installed near the outdoor unit for easy disconnect of power to the air conditioner. 3. An electrical circuit dedicated to the air conditioner shall be used for the power supply to the air conditioner. 4. Interconnecting wiring and conduits from the outdoor unit to the indoor unit are not provided with the air conditi
Résumé du contenu de la page N° 9
INDOOR UNIT OUTDOOR UNIT WIRING SYSTEM DIAGRAMS 9SRA-HE | 12SRA-HE | 15SRA-HE (115V - 60Hz) INDOOR UNIT L1 DISPLAY AND 9 RECEIVE BOARD N Terminal block of indoor unit FUSE 2 COMPULSIVE SWITCHING 3.15 A PIPE SENSOR 2 ACN BU 3 3 TEMP SENSOR 2 3 2 1 ACL BN 5 2 2 IN FAN CMU OR 5 STEP 1 1 MOTOR INDOOR CONTROL BOARD INDOOR UNIT WIRING DIAGRAM L1 N 3 2 1 Terminal block of outdoor unit OUTDOOR UNIT Power supply, 1 phase, 60 Hz BN CAPACITOR RD L1 R PROTECTOR WH C S N COMPRESSOR HIGH PRESSURE SWITCH BU
Résumé du contenu de la page N° 10
INDOOR UNIT OUTDOOR UNIT WIRING SYSTEM DIAGRAMS 18SRA-HE | 24SRA-HE (208-230V - 60Hz) INDOOR UNIT L1 DISPLAY AND 9 RECEIVE BOARD L2 Terminal block of indoor unit FUSE COMPULSIVE SWITCHING 2 3.15 A PIPE SENSOR 2 ACN BU 3 3 TEMP SENSOR 2 3 2 1 ACL BN 5 2 2 IN FAN CMU OR 5 STEP 1 1 MOTOR INDOOR CONTROL BOARD INDOOR UNIT WIRING DIAGRAM L1 L2 3 2 1 Terminal block of outdoor unit OUTDOOR UNIT Power supply, 1 phase, 60 Hz BN CAPACITOR RD L1 R PROTECTOR WH C S L2 COMPRESSOR HIGH PRESSURE SWITCH BU NO
Résumé du contenu de la page N° 11
ELECTRICAL CONNECTIONS FOR INDOOR AND OUTDOOR UNITS INDOOR UNIT 1. The indoor unit is powered from the outdoor unit. A sufficient length of conduit and wiring shall be used from the outdoor unit to the indoor unit. 2. To access the terminal block inside the indoor unit, remove the screw on the cover plate. (See Fig. A.) 3. Connect the inter unit conductors to terminals marked 1,2,3, on the indoor unit corresponding to the same numbered terminals from the outdoor unit. (See Fig.B.) Figure A
Résumé du contenu de la page N° 12
REFRIGERATION LINE CONNECTIONS When connecting the refrigerant tubing - Keep all tubing runs as short as possible. - Use the flare method for connecting tubing. - Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection. - Check carefully for leaks before starting the test run. Compressor 3-Way valve 2-Way valve Capillary tube Models 9SRA-HE 12SRA-HE 15SRA-HE 18SRA-HE 24SRA-HE Re
Résumé du contenu de la page N° 13
REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN INSTALLING UNIT Caution: The compressor POE oil for R-410A units is extremely susceptible to moisture absorption and could cause compressor failure. Do not leave system open to atmosphere any longer than necessary for installation. General Information Systems using R-410A refrigerant run at a pressure of approximately 1.6 times that of similar systems using R-22 and the energy efficiency is comparable. The R-410A refrigerant is a 50:50 mixture of R-32
Résumé du contenu de la page N° 14
TIGHTENING REFRIGERANT PIPING CONNECTIONS Caution: Remove the protection caps on the pipes and connect the assembly piping to each connector. First, tighten the nuts manually and then with a wrench by applying the tightening torque shown below. Flare nut size and tightening torque Class 2 (for R410A) Applicable size Diamètre (mm) x Tightening torque (Nm) 1/4 “ 17 x 14 to 18 3/8 “ 22 x 34 to 42 1/2 “ 26 x 49 to 61 5/8 “ 29 x 68 to 82 3/4 “ 36 x 100 to 120 Installation & service manual _11
Résumé du contenu de la page N° 15
SYSTEM EVACUATION Condensing unit liquid and suction valves are closed to contain the charge within the unit. The unit is shipped with the valve stems closed and caps installed. Do not open the valves until the system is evacuated. 1. Connect the vacuum pump with 250-micron capability to the services valves. 2. Evacuate the system to 250 microns or less using suction and liquid service valves. Using both valves is necessary for some compressors create a mechanical seal separating the sides of th
Résumé du contenu de la page N° 16
ADDITIONAL CHARGE AND DISTANCE Refrigerant suitable for a piping length of 20 ft (6 m) is charged in the outdoor unit at the factory. When the pipe is longer than 20 ft (6 m), additional charging is necessary. This operation can only be performed by a qualified refrigeration specialist. Additional amount must be added for each extra 3.3 ft (1 m), see the table below: 12SRA-HE | 15SRA-HE | Models 9SRA-HE 24SRA-HE 18SRA-HE Additional refrigerant 20 g (0.7 oz) 40 g (1.41 oz) 30 g (1.06 oz) Models 9
Résumé du contenu de la page N° 17
GAS LEAK CHECK Check that no gas escapes from the connections by using a leak detector or soapy water. A and B are the liquid and suction valves of the outdoor unit. C and D are the extremities of the indoor unit flared connections. Indoor unit check points C D A B Liquid and suction valves Installation & service manual _14
Résumé du contenu de la page N° 18
CHECKING AND TESTING OPERATIONS Perform the operation test after completing the gas leak check of the flare nut connections and the electrical connections. 1. To begin the test, turn on the power. 2. Press the auxiliary control button in the indoor unit or use the remote control to start the unit. 3. Check that all air conditioner functions are operating normally. A protection feature prevents the air conditioner from being started immediately after the unit has been turned off. There is a delay
Résumé du contenu de la page N° 19
TECHNICAL SPECIFICATIONS SPECIFICATIONS 15SRA-HE 18SRA-HE 24SRA-HE MODELS 9SRA-HE 12SRA-HE Performance ratings Nominal capacity 9 000 12 000 15 000 18 000 24 000 BTU/h Cooling S.E.E.R BTU/hW Cooling 15 13.5 14 13.5 13 Refrigerant type R-410A R-410A R-410A R-410A R-410A Dehumidifying capacity 4.1 Pt./H 1.9 3.1 3.5 5.2 Airflow circulation (High) 647 765 CFM 382 441 559 Indoor sound rating (High-Medium-Low) 47-44-40 48-44-40 52-49-45 dB(A) 44-40-33 45-42-34 Outdoor sound rating 55 56 59 dB(A) 50 52
Résumé du contenu de la page N° 20
OUTLINE AND DIMENSIONS Models: 9SRA-HE | 12SRA-HE | 15SRA-HE | 18SRA-HE | 24SRA-HE C Indoor unit B Outdoor unit D H E I In 9SRA-HE 12SRA-HE 15SRA-HE 18SRA-HE 24SRA-HE A 10 7/8 10 7/8 12 5/8 12 5/8 13 B 31 1/2 31 1/2 38 3/4 38 3/4 43 1/2 C 8 1/4 8 1/4 7 1/2 7 1/2 9 1/4 D 31 3/4 33 7/8 33 7/8 37 1/2 38 1/4 E 11 12 12 14 14 1/2 F 23 25 25 32 1/4 36 G 1/2 5/8 5/8 1 1/2 1 1/2 H 11 1/4 12 12 13 3/4 14 1/4 I 14 1/8 14 3/4 14 3/4 16 1/4 16 1/4 Installation & service manual _17 A G F