Résumé du contenu de la page N° 1
DONOT
DISCARD
Installation
Instructions
Models:
Installation and service of this
appliance should be performed by
ODGO324-IPI-LP
qualified personnel. Hearth & Home
Technologies suggests NFI certified
ODGO324-IPI-NG
or factory-trained professionals,
o r t e c h n i c i a n s
Outdoor Burner and Log Set
s u p e r v i s e d b y
Report # 324-L-15-4
an NFI certified
professional.
Check with your local
Résumé du contenu de la page N° 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Hearth & Home Technologies This owner’s manual should be retained for future reference. gas log set—an elegant and clean alternative to burning We suggest you keep it with your other important documents wood. The Hearth & Home Technologies gas log set you and product manuals. have selected is designed to provide the utmost in saf
Résumé du contenu de la page N° 3
WARNING WARNING Improper installation, adjustment, alteration, service HOT! DO NOT TOUCH. or maintenance can cause injury or property damage. SEVERE BURNS MAY RESULT. Refer to the owner’s information manual provided with CLOTHING IGNITION MAY RESULT. this appliance. For assistance or additional information Glass and other surfaces are hot during consult a qualified installer, service agency or the gas operation and cool down. supplier. CAUTION • Keep children away. • CAREFULLY SUPERVISE
Résumé du contenu de la page N° 4
• Gas Supply Pressure: Minimum inlet gas supply pressure must be 7.0 in. W.C. for natural gas or 11 in. W.C. for LP WARNING gas for the purpose of input adjustment. Maximum inlet Do NOT use this appliance if any part has been under gas pressure must not exceed 10.5 in. W.C. for natural water. Immediately call a qualified service technician gas or 13 in. W.C. for LP gas. The gas line supplying the to inspect the appliance and to replace any part of the appliance must be sufficient size to fu
Résumé du contenu de la page N° 5
Table 1 for Factory Built Fireplaces Table 2 for Masonary Built Fireplaces Free Opening Area (in square inches) of Chimney Damper for Venting combustion Free Opening Area (in square inches) of Chimney Damper for Venting combustion Chimney Ht. ODGO 324 ODGO 324 (Feet)* LP Gas Natural Gas Chimney Ht. ODGO 324 ODGO3 24 (Feet)* LP Gas Natural Gas 10 35.3 not approved 6 49.2 64 15 26.4 38.5 8 45.5 59.7 20 22.1 31.2 10 41.7 54.3 25 18.1 27.3 15 37.7 48.8 30 17.3
Résumé du contenu de la page N° 6
H. Lava Rock Installation Note: The state of Massachusetts requires that the • Pour Lava Rock into the burner pans to the point where chimney flue damper, when used with gas logs, be welded the burner pipe is covered. See Figure 5.. Be sure not to open or completely removed. In the Commonwealth of cover pilot assembly. Massachusetts this appliance must be installed by a • Inspect the pilot burner to ensure it is clear of any licensed plumber or gasfitter. lava rock. • The gas burns at the
Résumé du contenu de la page N° 7
K. Cleaning and Maintenance Instructions Always remember: • Do not place any combustible material near the appliance. • Do not place any paper, trash or other material on the log set or in the fireplace. • Do not touch any part of the appliance when it is in operation. • Do not operate this appliance without the fireplace screen closed. Your appliance is designed to be virtually maintenance free, although periodic visual inspection and cleaning is required. Follow the instructions below fo
Résumé du contenu de la page N° 8
• IPI Pilot Valve (IPI) L. Lighting Instructions FOR YOUR SAFETY READY BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an intermittent Pilot ignition (IPI) device which automatically lights the burner. DO NOT try to light the burner by hand. B. BEFORE LIGHTING,
Résumé du contenu de la page N° 9
M. Fequently Asked Questions Can I close the glass doors on my fireplace when using my gas logs? No. The gas log sets are designed for use in fireplaces with all fireplace doors fully opened. Operating your log set with the doors closed will cause overheating, premature failure of valve systems, and will void the warranty of your log set. What sort of maintenance do gas logs require? Vented gas logs do not require regular maintenance. However, it is a good idea to have valves, pilots and gas co
Résumé du contenu de la page N° 10
N. GO324 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV737 SRV709 SRV708 SRV816 SRV716 SRV728 SRV724 SRV808 SRV706 SRV707 SRV702 10 Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011
Résumé du contenu de la page N° 11
O. GO324 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. SRV737 SRV708 SRV709 SRV728 SRV716 SRV816 SRV724 SRV808 SRV707 SRV702 SRV706 Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011 11
Résumé du contenu de la page N° 12
Replacement Parts Grand Oak Gas Logs Service Parts Exploded Parts Diagram Beginning Manufacturing Date: 8/1/2010 ODGO Gas Logs Ending Manufacturing Date: Active 1 ODGO324 IPI Valve Assembly 15 ODGO 324 13 9 4 7 8 6 11 14 2 3 5 10 12 12 Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011
Résumé du contenu de la page N° 13
Grand Oak Gas Logs Service Parts Service Parts List Beginning Manufacturing Date: 8/1/2010 ODGO Gas Logs Ending Manufacturing Date: Active # Description of Part ODGO324 Qty. 1 Burner Pan & Grate Assembly (LP Gas) SRVODGOIPI-LP 1 1 Burner Pan & Grate Assembly (Natural Gas) SRVODGOIPI-NG 1 2 Switch 01-1070 1 3 *Pilot NG 07-1024 1 3 *Pilot LP 07-1023 1 4 Control Module 593-592 1 5 Battery Holder 593-594A 1 6 Valve NG 593-500 1 6 Valve LP 593-
Résumé du contenu de la page N° 14
Warranty 14 Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011
Résumé du contenu de la page N° 15
Hearth & Home Technologies • Grand Oak Gas Log Sets • 4004-320 2/2011 15
Résumé du contenu de la page N° 16
DONOT DISCARD Contact Information Please contact your Hearth & Home Technologies dealer with any questions or concerns. For the number of your nearest Hearth & Home Technologies dealer, please call 1-800-927-6841 or 1-888-427-3973. - NOTES - CAUTION DO NOT DISCARD THIS MANUAL • Read, understand • Leave this manual with • Important operating and follow these party responsible for a n d m a i n t e n a n c e instructions for safe use and operation. instructions included. i n s t a l l a t i