Résumé du contenu de la page N° 1
®
Model No. IMSB61502
IMSG61502
USER’S MANUAL
Serial No.
The serial number is found on a plastic
sign inside the spa behind the access
panel. Write the serial number in the
space above for reference.
Access Panel
QUESTIONS?
If you have questions, or if there
are missing parts, we will guar-
antee complete satisfaction
through direct assistance from
our factory.
TO AVOID UNNECESSARY
DELAYS, PLEASE CALL DIRECT
TO OUR TOLL-FREE CUSTOMER
HOT LINE. The trained techni-
cians on our customer hot line
Résumé du contenu de la page N° 2
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Choosing a L
Résumé du contenu de la page N° 3
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure 10. Never insert any object into any opening. that all users of the hydrotherapy spa are 11. Do not use breakable containers in or near adequately informed of all precautions. the hydrotherapy spa. 2. Use the hydrotherapy spa only a
Résumé du contenu de la page N° 4
20. DANGER—Risk of electric shock. Keep all physician before using the hydrotherapy spa. electrical appliances such as radios, tele- Pregnant women should not use the spa if phones, televisions, and lights at least five the water temperature is above 100°F; the feet away from the water. unborn child could be seriously harmed. This is especially important during the first 90 21. A wire connector is provided on the electron- days of the pregnancy. ics pack of the hydrotherapy spa to connect a 2 mi
Résumé du contenu de la page N° 5
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa. I
Résumé du contenu de la page N° 6
Before You Begin ® Congratulations for selecting the new IMAGE For your benefit, read this manual carefully before RENEW 615 hydrotherapy spa. The innovative using the RENEW 615. If you have questions after RENEW 615 spa allows you to enjoy all the benefits of reading the manual, call our Customer Service hydrotherapy in the comfort and privacy of your home. Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time Hydrotherapy is a proven method for soothi
Résumé du contenu de la page N° 7
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your 1. Check local building codes concerning th
Résumé du contenu de la page N° 8
Assembly Before beginning assembly, carefully read the ASSEMBLY REQUIRES THE FOLLOWING following information and instructions: TOOLS (not included): • Place all parts in a cleared area and remove the • One (1) phillips screwdriver packing materials from the spa shell. Do not dis- pose of the packing materials until assembly is • You may also need a small amount of soapy completed and the spa is operating. water. • During assembly, make sure that all parts are A wire connector is provided on th
Résumé du contenu de la page N° 9
3. Locate the three pillows. Each pillow can be 3 Pillow attached to the spa shell in a high position or a low position. To determine the high and low positions, Pillow Pillow attach one pillow to the spa shell, note its position, remove it, turn it 180°, and then re-attach it. Attach the three pillows in the desired positions. 4. The spa operates on a 240-volt power source and must be wired directly to a 30 amp Ground Fault Circuit Interrupter (GFCI) installed in your home. This procedure must
Résumé du contenu de la page N° 10
Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat five adults. Once you have tested the GFCI, you should verify the The spa holds 295 gallons of water and offers a heat- water flow from the pumping unit. Set the air control ing system (80°F to 104°F), a filtration system, and on the console to the lowest setting (see USING THE adjustable hydrotherapy jets. Follow the guidelines CONTROLS on page 12). The pumping unit will heat below to use and maintain the spa for your long-term
Résumé du contenu de la page N° 11
Spa Shell Diagram A P P A A D C A K F B K G J I E N M L P O H Refer to the diagram above. The function of each way to help sanitize the spa with minimal chemical component is explained below. treatment. A. The four adjustable, directional jets can be pivot- H. The skimmer cleans the surface of the water. ed to direct their water flow. To open the jets, turn the rims counterclockwise; to close the jets, turn I. The temperature probe monitors water temperature. the rims clockwise. If no air fl
Résumé du contenu de la page N° 12
Using the Controls Console Air Control L Air Control M Display Temperature Jet Light Temperature Up Button Button Button Down Button Refer to the diagram above. The function of each Air Controls: Determine the amount of air flowing control is explained below: through the spa jets during operation. Refer to the diagram below. Air control M controls air flow to the Jet Button: Turns the spa jets on and off. This is a jets labeled M. Air control L controls air flow to the jets two-speed button. If
Résumé du contenu de la page N° 13
Maintenance The hydrotherapy spa is designed to provide years of MAINTAINING THE SPA COVER enjoyment. Please follow the guidelines below to properly maintain your spa. The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner MAINTENANCE SCHEDULE on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover Daily entirely. Use a non-silicone-based vinyl conditioner on • Check the water level and refill the spa to
Résumé du contenu de la page N° 14
WATER CHEMISTRY ATTACHING AND REMOVING ACCESS PANELS CAUTION: The chemicals used to maintain the pH To locate the access panels, refer to the drawing on balance of the water and to sanitize the water can page 6. Turn off the power to the spa. To remove an be dangerous. Always follow these basic guide- access panel, first remove the four indicated screws. lines when handling the chemicals: Slide the access panel down and then pull the bottom 1. Always read and follow the directions on the of it a
Résumé du contenu de la page N° 15
To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE 1. Using the console, adjust the temperature to the The hydrotherapy spa is designed for year-round use. lowest setting. If you decide to store the spa for the winter, store it in 2. Shut off the power at the circuit breaker or GFCI. a warm, dry location. Follow the steps below to winter- 3. Remove the long access panel from the spa. ize the spa. 4. Remove the end of the drain hose from the spa. 1. Drain the spa (see DRAI
Résumé du contenu de la page N° 16
Trouble-shooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE of 6°F per hour. If you are using the spa indoors and the room temperature is main- a. Check to see if the GFCI breaker is tripped or tained at 70°F, it will take a
Résumé du contenu de la page N° 17
b. A clamp or seal inside the pump compartment 12. SYMPTOM: THE CONSOLE DISPLAYS THE may be loose. Check inside the pump compart- WORDS “COOL” OR “ICE” ment for excess water and watch the pump unit while it is operating to see if water drips from a. This is a normal function of the spa; no action any of the plumbing. If you can identify the is necessary. The word “COOL” will appear in location of the leak inside the spa jet unit, tight- the display if the temperature of the water is en the clamp
Résumé du contenu de la page N° 18
R0901A Part List—Model No. IMSB61502/IMSG61502 Key No. Qty. Description Key No. Qty. Description 1 1 Thermometer Fitting 35 1 Cover Ring 2 2 Long Access Panel 36 3 Nozzle Housing 3 3 Face Ring 37 4 Nozzle Retainer Ring 4 4 Small Rotator 38 4 1/4” Washer 5 2 Short Access Panel 39 1 Rotator 6 4 Pivot Ring 40 1 Light Cover, Red 7 32 #10 x 2” Sheet Metal Screw 41 1 Light Cover, Blue 8 1 Filter Cover 42 1 Diverter 9 8 Wood Screw 43 1 Basket 10 3 Medium Jet Housing 44 1 Filter Door 11 1 Spa
Résumé du contenu de la page N° 19
R0901A Exploded Drawing—Model No. IMSB61502/IMSG61502 11 9 38 38 29 29 13 9 38 13 38 8 20 28 9 33 29 27 52 16 14* 1 52 9 24 12 51 21 3 19 22 30 26 3 34 19 4 26 31 6 19 10 25 23 36 26 39 35 26 32 25 37 2 5 18 17 7 7 18 25 19
Résumé du contenu de la page N° 20
Ordering Replacement Parts To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be pre- pared to give the following information when calling: 1. The MODEL NUMBER of the product (IMSB61502/IMSG61502) ® 2. The NAME of the product (IMAGE RENEW 615) 3. The SERIAL NUMBER of the product (see the front cover of this manual) 4. The KEY NUMBER an