Résumé du contenu de la page N° 1
OPERATION & PARTS MANUAL
GloBug
MODEL GB114BC
LIGHTING SYSTEM
(FOR USE WITH MQ SERIES GENERATORS)
Revision #3 (03/22/06)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALL TIMES.
Résumé du contenu de la page N° 2
PAGE 2 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)
Résumé du contenu de la page N° 3
HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MULTIQUIP CORPORATE OFFICE 18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 FAX: 310-537-3927 Email: mq@multiquip.com Internet: www.multiquip.com PARTS DEPARTMENT 800-427-1244 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 MAYCO PARTS 800-306-2926 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 SERVICE DEPARTMENT 800-478-1244 FAX: 310-537-4259 310-537-3700 TECHNICAL ASSISTANCE 800-478-1244 FAX: 310-631-5032
Résumé du contenu de la page N° 4
TABLE OF CONTENTS MQ GLOBUG LIGHTING MQ GLOBUG LIGHTING MQ GLOBUG LIGHTING COMPONENT DRA COMPONENT DRA COMPONENT DRAWINGS WINGS WINGS MQ GLOBUG LIGHTING MQ GLOBUG LIGHTING COMPONENT DRA COMPONENT DRAWINGS WINGS SYSTEM SYSTEM SYSTEM SYSTEM SYSTEM Nameplate and Decals.......................................42-43 Here's How To Get Help ............................................ 3 T-Handle Assy. ...................................................44-45 Table Of Contents .............................
Résumé du contenu de la page N° 5
PARTS ORDERING PROCEDURES When ordering parts, please supply the following information: ❒❒❒❒❒ Dealer account number ❒❒❒ Dealer name and address ❒❒ ❒❒❒ Shipping address (if different than billing address) ❒❒ ❒❒❒❒❒ Return fax number ❒❒❒❒❒ Applicable model number ❒❒❒❒❒ Quantity, part number and description of each part ❒❒❒❒❒ Specify preferred method of shipment: ✓ FedEx or UPS Ground Note: Unless otherwise indicated by customer, all ✓ FedEx or UPS Second Day or Third Day orders are treated as “Stan
Résumé du contenu de la page N° 6
GLOBUG LIGHTING SYSTEM — SAFETY MESSAGE ALERT SYMBOLS Potential hazards associated with the GloBug Lighting FOR YOUR SAFETY AND THE SAFETY OF OTHERS! System operation will be referenced with Hazard Symbols Safety precautions should be followed which appear throughout this manual, and will be referenced at all times when operating this in conjunction with Safety Message Alert Symbols. equipment. Failure to read and understand the Safety Messages and HAZARD SYMBOLS Operating Instructions could re
Résumé du contenu de la page N° 7
GLOBUG LIGHTING SYSTEM — SAFETY MESSAGE ALERT SYMBOLS CAUTION - Rotating Parts CAUTION - Equipment Damage Messages NEVER operate equipment with covers, Other important messages are provided throughout this or guards removed. Keep fingers, hands, manual to help prevent damage to your lighting system, hair and clothing away from all moving other property, or the surrounding environment. parts to prevent injury. CAUTION - Accidental Starting This lighting system, other ALWAYS place the power sourc
Résumé du contenu de la page N° 8
GLOBUG LIGHTING SYSTEM — RULES FOR SAFE OPERATION ■ NEVER touch the hot exhaust manifold, WARNING - READ THIS MANUAL muffler or cylinder. Allow these parts to cool before servicing engine or mixer. Failure to follow instructions in this manual may lead to Serious Injury or even Death. This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used ■ High Temperatures – Allow the engine to
Résumé du contenu de la page N° 9
GLOBUG LIGHTING SYSTEM — RULES FOR SAFE OPERATION ■ ALWAYS make sure that the GloBug is secure on firm level LIFTING/TRANSPORTING THE GLOBUG ground so that it cannot slide or shift around, endangering ■ ALWAYS use the lifting hanger, when lifting of the GloBug workers. Also keep the immediate area free of bystanders. is required. ■ ALWAYS keep area behind GloBug clear of people while raising and lowering mast. ■ To prevent the GloBug from overturning, NEVER use in winds that exceed 22 mph(10m/
Résumé du contenu de la page N° 10
GLOBUG LIGHTING SYSTEM — RULES FOR SAFE OPERATION BALLOON SAFETY AND CARE ■ When transporting the GloBug over smooth roads, place mast in stow position. Tighten the lamp adjustment lever ■ To prevent serious burns, NEVER touch or unzip the and mast adapter set screw firmly to secure the balloon balloon envelope when the lamp is on. to the mast before transporting. This will prevent the ■ To prevent the balloon from deformation, NEVER use GloBug balloon/light assembly from falling down or being
Résumé du contenu de la page N° 11
GLOBUG LIGHTING SYSTEM — RULES FOR SAFE OPERATION Maintenance Safety DANGER - GloBug Electric Shock Hazards ■ NEVER lubricate components or attempt service on a running ALWAYS keep electrical cords in good condition. Worn, GloBug. bare or frayed wiring can cause electrical WET ■ ALWAYS allow the GloBug a proper amount of time to cool HANDS shock, thus causing Bodily Harm or before servicing. even Death. ■ Keep the GloBug in proper running condition. NEVER grab or touch a live power cord with wet
Résumé du contenu de la page N° 12
GLOBUG LIGHTING SYSTEM — OPERATION AND SAFETY DECALS Machine Safety Decals The GloBug is equipped with a number of safety decals, Figures 1A through 1C. These decals are provided for operator safety and maintenance information. The illustrations below and on the next page show these decals as they appear on the machine. Should any of these decals become unreadable, replacements can be obtained from your dealer. Figure 1A. Operation and Safety Decals PAGE 12 — GLOBUG LIGHTING SYSTEM — OPERATION
Résumé du contenu de la page N° 13
GLOBUG LIGHTING SYSTEM — OPERATION AND SAFETY DECALS Figure 1B. Operation and Safety Decals (Continued) GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06) — PAGE 13
Résumé du contenu de la page N° 14
GLOBUG LIGHTING SYSTEM — OPERATION AND SAFETY DECALS Figure 1C. Operation and Safety Decals (Continued) PAGE 14 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)
Résumé du contenu de la page N° 15
GLOBUG LIGHTING SYSTEM — SPECIFICATIONS Table 1. Specifications GloBug MC odel GB114B IC nput Voltage 120 VA Fe requency 60 Hz Single-Phas Ms ax. Current 9.5 Amp W) ind Stability with Generator 65 mph (80.46 kph W) eight (less generator) 243 lbs. (110 kg Lamp Le amp Type (1)1000 Watt Metal Halidad L0 umens 112,00 L) ight Coverage (360°) 150 ft. (45.72 meters S. urface Temperature (Longitudinal) 476.6°F (247°C) Max S. urface Temperature (Transversal) 417.2°F (214°C) Max Fan Motor Bz alloon Fan M
Résumé du contenu de la page N° 16
GLOBUG LIGHTING SYSTEM — DIMENSIONS Figure 2. Dimensions TABLE 2. DIMENSIONS Reference Reference D) escription Dimension ft. (mm. D) escription Dimension ft. (mm. Letter Letter AeW) heel Bas 2F .66 ft. (811 mm.M) ax. Height (Mast Deployed Position) 16.41 ft. (5,004 mm. B)H) eight (Mast Stowed Position5G .5 ft. (1,676 mm. L) ength (Front to Rear Wheel) 3.41 ft. (1,041 mm. CtH) andle Heigh 2H .91 ft. (889 mm.L) ength (Front Wheel to Outrigger) 4.83 ft. (1,473 mm. DhB) alloon Bag Lengt 2I .25 ft
Résumé du contenu de la page N° 17
GLOBUG LIGHTING SYSTEM — FLOODLIGHT FOOTCANDLE PLOT Based on 360°glare-free coverage. Figure 3. Floodlight Footcandle Plot (Bal120-Standard) GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06) — PAGE 17
Résumé du contenu de la page N° 18
GLOBUG LIGHTING SYSTEM — FLOODLIGHT FOOTCANDLE PLOT Based on 360°glare-free coverage. Figure 4. Floodlight Footcandle Plot (BAL120R-Reflector) PAGE 18 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)
Résumé du contenu de la page N° 19
GLOBUG LIGHTING SYSTEM — FLOODLIGHT FOOTCANDLE PLOT 360 degree coverage Figure 5. Floodlight Footcandle Plot (BAL-115D-Drum Shaped) GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06) — PAGE 19
Résumé du contenu de la page N° 20
GLOBUG LIGHTING SYSTEM — GENERAL INFORMATION The lighting system can be raised vertically in excess of 31.5 feet The Multiquip GloBug Lighting System is a general purpose (9.6 meters) by means of a manual winch. The tower tensioning floodlight tower intended for emergency and remote lighting system is designed to provide the necessary tension to safely conditions. The GloBug can be powered by a variety of control the pivot of the tower. Outriggers must always be deployed Multiquip's series gen