03/03/27 14:18:50 31Z22600_001 The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands. Keep this owner’s manual handy, so you can refer to it at any time. This owner’s manual is considered a permanent part of the
Résumé du contenu de la page N° 3
03/03/27 14:18:56 31Z22600_002 Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a symbol. That information is intended to help you avoid damage to your gene
Résumé du contenu de la page N° 4
03/03/27 15:49:04 31Z22600_003 A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others. Of course, it is not practical or possible to warn you about all the hazards associated with operating
Résumé du contenu de la page N° 5
03/03/27 14:19:13 31Z22600_004 CONTENTS SAFETY ....................................................................................................... 5 Safety Label Locations ........................................................................ 5 Safety Information ............................................................................... 6 COMPONENT IDENTIFICATION ............................................................... 8 CONTROLS ................................................
Résumé du contenu de la page N° 6
03/03/27 14:19:16 31Z22600_005 TRANSPORTING/STORAGE ................................................................... 44 TROUBLESHOOTING .............................................................................. 47 WIRING DIAGRAM .................................................................................. 49 SPECIFICATIONS ..................................................................................... 51 ASSEMBLY .................................................................
Résumé du contenu de la page N° 7
03/03/27 14:19:34 31Z22600_006 SAFETY SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement. 5
Résumé du contenu de la page N° 8
03/03/27 14:19:41 31Z22600_007 SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency. Understand the use of all generator controls, output receptacl
Résumé du contenu de la page N° 9
03/03/27 14:19:53 31Z22600_008 Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. If the generator is stored outdoors, unprotected from the weather, check the ground-fault circuit interrupter (GFCI), and all other electrical co
Résumé du contenu de la page N° 10
03/03/27 17:19:21 31Z22600_009 COMPONENT IDENTIFICATION ENGINE SWITCH CONTROL PANEL CHOKE ROD AIR CLEANER FUEL VALVE LEVER RECOIL STARTER GRIP OIL FILTER CAP/DIP STICK ENGINE SERIAL NUMBER OIL DRAIN BOLT CONTROL PANEL 120 ONLY 120/240 1: Except EB3800X VOLTAGE SELECTOR SWITCH GFCI TEST BUTTON AC CIRCUIT PROTECTORS GFCI RESET BUTTON 120/240 AC RECEPTACLE 1 AUTO THROTTLE SWITCH CIRCUIT BREAKER GROUND TERMINAL AC RECEPTACLES 8
Résumé du contenu de la page N° 11
03/03/27 14:20:07 31Z22600_010 LIFTING HANGER TRANSPORT HANDLE FUEL TANK CAP FUEL GAUGE SPARK PLUG CAP STAND FRAME SERIAL NUMBER MUFFLER WHEEL *Record the engine and frame serial numbers for your future reference. Refer to these serial numbers when ordering parts, and when making technical or warranty inquiries (see page 62 ). Frame serial number: Engine serial number: 9
Résumé du contenu de la page N° 12
03/03/27 14:20:16 31Z22600_011 CONTROLS Engine Switch To start and stop the engine. Switch position: OFF: To stop the engine. ON: To run the engine. ENGINE SWITCH ON O OF FF F Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. STARTER GRIP 10
Résumé du contenu de la page N° 13
03/03/27 14:20:22 31Z22600_012 Fuel Valve Lever The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the fuel valve lever to the OFF position after stopping the engine. FUEL VALVE LEVER OFF ON Choke Rod The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke rod manually. Pull the rod o
Résumé du contenu de la page N° 14
03/03/27 14:20:32 31Z22600_013 Voltage Selector Switch (Dual Voltage System) The voltage selector switch switches the main power carrying windings of the generator to produce ‘‘120V ONLY’’ or ‘‘120/240V’’. If a 240V appliance is connected to the 4-prong receptacle, the switch must be in the ‘‘120/240V’’ position. If only a 120V appliance is being connected to any of the 120V 3-prong receptacles, select the ‘‘120V ONLY’’ position. Switch Position 120/240V: The 120V and 120/240V receptacles can be
Résumé du contenu de la page N° 15
03/03/27 14:20:40 31Z22600_014 Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine (the engine switch will remain in the ON position). The Oil Alert system should not take the place of checking the oil level before eachuse. If the engine stops and will not restart, check the engine oil level (se
Résumé du contenu de la page N° 16
03/03/27 14:20:49 31Z22600_015 Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle, or if the ground fault circuit interrupter (GFCI) detects a ground fault current. Check the following if the circuit breaker switches OFF automatically: When the GFCI RESET button is extended (page 18): Unplug all appliances from the receptacles and check the appliance for any defects as described in TROUBLESHO
Résumé du contenu de la page N° 17
03/03/27 14:20:54 31Z22600_016 Circuit Protector The circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at the 20A 120V, 30A 120V locking plug, or 120/240V locking plug receptacle. If a circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the circuit protector ON. CIRCUIT PROTECTORS ON 1 OFF 1: Except EB3800X 15
Résumé du contenu de la page N° 18
03/03/27 14:21:00 31Z22600_017 Ground Fault Circuit Interrupter (GFCI) Using the generator in rain, snow or near water can lead to death from electric shock. Keep the generator dry. All receptacles on the generator are protected by a ground fault circuit interrupter (GFCI) for protection against the shock hazard of ground fault current. The GFCI has TEST and RESET buttons and is connected to the circuit breaker. An example of ground fault current is the current which would flow through a person
Résumé du contenu de la page N° 19
03/03/27 14:21:05 31Z22600_018 Observe the following precautions to ensure proper GFCI operation and to reduce shock hazards: Use grounded 3-conductor extension cords, tools, and appliances, or double-insulated tools and appliances. Inspect cords and plugs, and replace if damaged. Do not use cord lengths greater than 164 feet (50 meters), and do not use multiple tools and appliances with built-in noise filters. Such use may activate the GFCI and trip the circuit breaker. 17
Résumé du contenu de la page N° 20
03/03/27 14:21:10 31Z22600_019 Inspection: Always check GFCI operation before using the generator. You risk electric shock if you operate this generator with a faulty GFCI (ground fault circuit interrupter). Test GFCI before use. If the GFCI fails testing, do not use your generator. Contact your Honda dealer. 1. Unplug all tools and appliances from the generator. 2. Start the engine. 3. Turn the circuit breaker to the ON position. 4. Turn the Auto Throttle switch to the OFF position. 5. Press th