Résumé du contenu de la page N° 1
Résumé du contenu de la page N° 2
The engine exhaust from this product contains chemicals known to the State The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands. Keep this owner's manual handy, so you can refer to it at any time. This owner's manual is considered a permanent part of the generator and should remain with the generator if resold. The i
Résumé du contenu de la page N° 3
Congratulations on your selection of a Honda generator. We are certain you will be pleased with your purchase of one of the finest generators on the market. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. As you read this manual, you will find information preceded by a VI symbol. That information is intended to he
Résumé du contenu de la page N° 4
A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. And using this generator safely is an important responsibility. To help you make informed decisions about safety, we have provided operating procedures and other information on labels and in this manual. This information alerts you to potential hazards that could hurt you or others. Of course, it is not practical or possible to warn you about all the hazar
Résumé du contenu de la page N° 5
CONTENTS SAFETY ....................................................................................................... 5 Safety Label Locations ........................................................................ 5 Safety Information ............................................................................... 7 COMPONENT IDENTIFICATION ............................................................... 9 CONTROLS ......................................................................
Résumé du contenu de la page N° 6
MAINTENANCE ....................................................................................... 29 The Importance of Maintenance ....................................................... 29 Maintenance Safety ........................................................................... 30 Emission Control System Information ............................................. 31 Air Index .............................................................................................. 33 ....
Résumé du contenu de la page N° 7
SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda generator dealer for a replacement. ISMAllDN SWlTCH IUS IEEN INSTALLED BY A LIUNPD EUCTMCIU. / I DO NOT USE INDOORS. EXHAUST GAS CONTAINS POISONOUS (WARNING CARBON MONOXIDE. NE PAS UTlLlSER DANS UN ENOROIT FERME A CAUSE DU I RISOUE DEMPOISONNEMENT DU GAZ. I . NO LO USE EN LUG
Résumé du contenu de la page N° 8
1 MADE IN JAPAN ($ ' EM2500X HONDA MOTOR co., LTD. CAUTION DC VOLTAGE 12V WITH RECOMMENDED OIL FREQUENCY CURRENT 8.3A BEFORE USING. RATED OUTPUT 2.3kVA FOR DETAILED EXPLANATION. FUEL GASOLINE SEE THE OWNER'S MANUAL. PHASE (PETROL) 8 4 I \ MADE IN JAPAN ' EM 1800X HONDA MOTOR co., LTD. CAUTION DC VOLTAGE 12V BE SURE TO FILL CRANKCASE VOLTAGE CURRENT 8.3A WITH RECOMMENDED OIL FREQUENCY BEFORE USING. RATED OUTPUT 1.5kVA FOR DETAILED EXPLANATION, MAX
Résumé du contenu de la page N° 9
SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency. Understand the use of all generator controls, outpu
Résumé du contenu de la page N° 10
~~~ Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry. If the generator is stored outdoors, unprotected from the weather, check all electrical components on the control pane
Résumé du contenu de la page N° 11
COMPONENT IDENTIFICATION ~ ENGINE SWITCH VOLT METER AIR CLEANER SEDIMENT CUP RECOIL STARTER GRIP DC CIRCUIT PROTECTOR ENGINE SERIAL NUMBER 9
Résumé du contenu de la page N° 12
FUEL TANK CAP FUEL METER \ . PLUG CAP FRAME SERIAL NUMBER \ MUFFLER *Record the engine and frame serial numbers for your future reference. Refer to these serial numbers when ordering parts, and when making technical or warranty inquiries (see page 49 ). Frame serial number: Engine serial number: 10
Résumé du contenu de la page N° 13
CONTROLS ENGINE SWITCH To start and stop the engine. Switch position: OFF: To stop the engine. ON: To start and run the engine. ( [-[ ON - ENGINE SWITCH RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. riiZEi4 Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.
Résumé du contenu de la page N° 14
FUEL VALVE LEVER The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the ON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the fuel valve lever to the OFF position after stopping the engine. FUEL VALVE LEVER CHOKE LEVER The choke is used to provide proper starting mixture when the engine is cold. It can be opened and closed by operating the choke lever
Résumé du contenu de la page N° 15
AC CIRCUIT BREAKER The AC circuit breaker will automatically switch OFF if there is a short circuit or an overload of the generator at the AC receptacle. If the AC circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the AC circuit before switching the AC circuit breaker ON again. The AC circuit breaker may be used to switch the generator AC power ON or OFF. 13
Résumé du contenu de la page N° 16
OIL ALERT@ SYSTEM The Oil Ale& system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert? system will automatically stop the engine (the engine switch will remain in the ON position). If the engine stops and will not restart, check the engine oil level (see page 23 ) before troubleshooting in other areas. , OIL FILLER HOLE
Résumé du contenu de la page N° 17
VOLT METER The volt meter displays the voltage the generator is producing. VOLTAGE ADJUSTMENT KNOB Although voltage adjustment is usually not required, fine adjustments may be made by turning the voltage adjustment knob. Use the generator at the specified voltage (1 20 V). VOLT METER VOLTAGE ADJUSTMENT KNOB 15
Résumé du contenu de la page N° 18
DC TERMINALS The DC terminals may ONLY be used for charging 12 volt automotive type batteries. (+) terminal and The terminals are colored red to identify the positive black to identify the negative (-1 terminal. The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal). DC CIRCUIT PROTECTOR The DC circuit protector automatically
Résumé du contenu de la page N° 19
GENERATOR USE CONNECTIONS TO A BUILDING ELECTRICAL SYSTEM Connections for standby power to a building electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may elec
Résumé du contenu de la page N° 20
AC APPLICATIONS Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been ex