Résumé du contenu de la page N° 1
120 VOLTS
RET S E E S TT
ENM
00000005
120 VOLTS FULL POWER SELECTOR 120/240 VOLTS
RESET
120 120
ONLY 240V
RESET RESET
TEST
ENM
00000005
HOURS 1/10
240 VOLTS
Auto-Idle RESET
ON OFF
RESET
HOURS 1/10
®
PORTABLE GASOLINE
GENERATORS
OWNER’S OPERATION AND INSTALLATION MANUAL
Generator Models: RGH3000, RGH3000PR, RGH5500, RGH5500IE,
RGH7500IE, and RGH11000IE
IMPORTANT: Read and understand this manual before operating or servicing
generator. Improper use of generator can cause serious injury
Résumé du contenu de la page N° 2
® PORTABLE GASOLINE GENERATORS 1. Gasoline presents a hazard of fire or ex- • Do not use any worn or damaged SAFETY plosion. Gasoline is flammable. Its va- electric cords. Electric shock or dam- INFORMATION por is explosive. age to generator may result. • Keep fuel out of children’s reach. • Do not wear damp clothing or wet • Refuel generator in a well-vented shoes when using generator. WARNINGS area. Do not fill fuel tank in the dark. 4. Guard against burns. Hot engine parts IMPORTANT: Read th
Résumé du contenu de la page N° 3
FULL POWER 120 VOLTS 120/240 VOLTS RESET 120 120 ONLY 240V RESET RESET TEST ENM 00000005 HOURS 1/10 OWNER’S MANUAL SAFETY PRODUCT INFORMATION IDENTIFICATION Continued 9. Only a qualified electrical service per- son should service and repair generator. • Generator produces high voltage. Use extreme caution when working Gas Cap/Fuel Gauge on electrical parts. Control • Always remove spark plug wire from Panel spark plug before servicing. This will prevent accidental starting. • When working
Résumé du contenu de la page N° 4
® PORTABLE GASOLINE GENERATORS GENERAL VENTILATION HIGH AND LOW INFORMATION TEMPERATURE DANGER: Use only in well- vented areas. Make sure area has Reddy portable generators are rugged and OPERATION plenty of free-moving, fresh, out- compact. These models provide dependable, side air. Never run generator in Air temperature affects generator output. trouble-free service. The alternators are an enclosed or confined area. Output drops 1% for each 10° temperature brushless with revolving fields. Hon
Résumé du contenu de la page N° 5
OWNER’S MANUAL SPECIFICATIONS RGH5500 MODEL RGH3000 RGH3000PR RGH5500IE RGH7500IE RGH11000IE Electrical Rated Wattage 2500 2500 5000 7000 10,000 Rated Amperage 120 V 20.8 20.8 41.7 57 83.3 240 V –– –– 20.8 28.3 41.7 Receptacle 120-V Duplex –– –– Yes Yes Yes 120-V, 20-A Duplex –– –– –– –– –– 120-V, 15-A GFCI Yes Yes Yes Yes Yes 120-V Twist-Lock No No 30 Amp 30 Amp 30 Amp 120/240-V Twist-Lock No No 20 Amp 30 Amp 30 Amp 120-V Full-Power Switch No No Yes No No 120/240-V, 50-A No No No No Yes General
Résumé du contenu de la page N° 6
RESET TEST ® PORTABLE GASOLINE GENERATORS 120 VOLT ONLY: This position sends full GROUND FAULT CIRCUIT GENERATOR power to the 120V receptacles only. 240V INTERRUPTER RECEPTACLE power is not available. Use this position FEATURES All models have a 120-volt ground fault when powering 120V items only. circuit interrupter (GFCI) receptacle. The OIL ALERT SYSTEM 120/240 VOLT: This position sends full GFCI receptacle is on the control panel or The oil alert system protects the engine from power to the
Résumé du contenu de la page N° 7
OWNER’S MANUAL GENERATOR ENGINE OIL FUEL FEATURES We ship the generator without oil in the WARNING: Gasoline presents engine crankcase. You must add oil before Continued a hazard of fire or explosion. starting engine. See engine owner’s manual Gasoline is flammable. Its vapor for specific oil type. ENGINE CIRCUIT BREAKER is explosive. (Models RGH5500IE, • Keep fuel out of children’s CHECKING OIL LEVEL AND reach. RGH7500IE, and RGH11000IE) ADDING OIL • Refuel generator in a well- This circuit br
Résumé du contenu de la page N° 8
120 ONLY 120 240V ENM 00000005 HOURS 1/10 FULL POWER ® PORTABLE GASOLINE GENERATORS Always wear safety glasses when working BATTERY with battery. Make sure battery terminals (Models RGH5500IE, are clean. Make sure cable connections are RGH7500IE, and RGH11000IE) tight. Always shut down engine before removing WARNING: Battery gives off or attaching battery cables. Always remove explosive gases. Keep sparks, the negative (–) cable first. Always attach flames, and cigarettes away. Do negativ
Résumé du contenu de la page N° 9
HOURS 1/10 FULL POWER 120 120 ONLY 240V ENM 00000005 OWNER’S MANUAL BATTERY GENERATOR EXTENSION Continued GROUNDING CORDS Only use grounded extension cords. Be sure WARNING: You must prop- to use extension cord with proper wire gauge erly earth-ground generator be- size. See chart below. Nut fore starting. This will help guard against deadly electric shock. Recommended Minimum Wire Only use grounded plugs with Gauges (AWG) for Extension generator. Only use grounded ex- Cords Battery tensi
Résumé du contenu de la page N° 10
® PORTABLE GASOLINE GENERATORS 1. Make two lists of items you want pow- ent size motors. For example: an elec- STANDBY ered by generator. List all motors and tric motor nameplate states 5 amps at 120 volts. 5 amps x 120 volts = 600 INSTALLATION TO motor powered appliances in one. List all lights, small appliances, etc. in the watts running. Multiply this figure by HOME OR other. For standby service to home or 3. This will show the starting watts building, only include items you must needed. 600
Résumé du contenu de la page N° 11
240 VOLTS RESET RESET RESET RESET 120 VOLTS RESET 120 120 ONLY 240V RESET RESET TEST ENM 00000005 HOURS 1/10 OWNER’S MANUAL Model RGH11000IE also has a 120/240V, POWER CORD AND PLUG OPERATION 50-amp receptacle (see Figure 15). REQUIREMENTS GENERAL INFORMATION Models RGH3000 and RGH3000PR have 120V, 30-amp twist-lock receptacle only the 120V, 15-amp GFCI duplex recep- This generator is not large enough to power • NEMA L5-30P plug tacle. your entire home. Do not connect generator • Three-wir
Résumé du contenu de la page N° 12
® PORTABLE GASOLINE GENERATORS 4. Start the engine. OPERATION Choke Button A. Recoil Starter Continued Pulled Out Turn engine switch to the ON position (Closed Position) PRESTART (see Figures 19 and 20). Remove slack from starter rope by lightly pulling Operate generator on a firm, dry, and clean starter grip. Next, pull starter rope surface. The surface must be level. Protect briskly. generator from heavy dust, sand, dirt, rain, IMPORTANT: Do not let starter grip or snow. Do not locate generato
Résumé du contenu de la page N° 13
OWNER’S MANUAL Fuel Valve Lever STOPPING ENGINE OPERATION (Off Position) IMPORTANT: The engine speed is preset. Continued The throttle is locked in preset position. Do not adjust throttle. HIGH ALTITUDE OPERATION Follow the steps below to stop engine. This generator will not perform well at high 1. Remove all electrical loads from gen- altitudes without proper adjustment. See erator (see Disconnecting Electrical engine owner’s manual for details. Loads). Remove electrical loads one at ADDING ELE
Résumé du contenu de la page N° 14
® PORTABLE GASOLINE GENERATORS IMPORTANT: Keep generator level when MAINTENANCE WARNING: The muffler be- servicing. Never turn generator upside down comes very hot during operation. AND REPAIRS or stand it on end to service. The muffler remains hot for a Note: We supply the engine owner’s manual while after shutdown. Let engine WARNING: Only a qualified with generator. Refer to that manual for cool before storing. electrical service person should questions concerning engine maintenance service
Résumé du contenu de la page N° 15
White LINE Black Red Black Green/Yellow Green White White Red 120V, 15A 120/240V 20A 120V, 15A 120V, 30A Receptacle Circuit Receptacle Receptacle Receptacle White Breaker 20A Circuit T1 T2 GFCI Breaker 25A Circuit Full Pwr Breaker Selector Red Black 20A Switch Circuit Breaker Black White T3 25A LINE T4 Hour Meter Yellow Green White Green Black Black Red Red Black Red Black Green Main Capacitor Auxiliary Windings Phase Stator White White Stator T2 T1 T3 T4 Rotor T1 T2 T3 T4 T1 T4 T3 T2 Green Whi
Résumé du contenu de la page N° 16
Green 120V, 15A Receptacle ® PORTABLE GASOLINE GENERATORS WIRING DIAGRAMS Continued Green/Yellow Green Black 120/240V 30A 120V, 15A 120V, 15A Circuit Receptacle Receptacle Receptacle Breaker 20A White White Circuit Duplex T1 Red GFCI White Breaker 30A White T2 Circuit Breaker 20A Black Circuit Breaker T3 30A LINE Hour Meter T4 White Yellow Green Black Black Red Black Black Red Auxiliary Main Capacitor Windings Phase Stator White White T2 T1 T3 T4 Rotor Stator T1 T4 T3 T2 T1 T2 T3 T4 Green White
Résumé du contenu de la page N° 17
OWNER’S MANUAL TECHNICAL REPLACEMENT PARTS CENTRALS These Parts Centrals are privately owned SERVICE PARTS businesses. They have agreed to support our You may have further questions about in- Note: Use only original replacement parts. customer’s needs by providing original re- stallation, operation, or troubleshooting. This will protect your warranty coverage for placement parts and accessories. parts replaced under warranty. If so, contact DESA International’s Techni- Baltimore Electric cal Ser
Résumé du contenu de la page N° 18
® PORTABLE GASOLINE GENERATORS 1 7 ILLUSTRATED PARTS LIST FOR MODELS RGH3000 AND 2 4 RGH3000PR ALTERNATOR ASSEMBLY 22 5 This list contains replaceable parts used in 6 3 14 your generator. When ordering parts, fol- 21 20 low the instructions listed under Replace- 15 ment Parts on page 17 of this manual. 13 19 17 16 15 13 7 12 8 18 9 7 10 11 7 KEY PART KEY PART NO. NUMBER DESCRIPTION QTY. NO. NUMBER DESCRIPTION QTY. 099722-02 Alternator Assembly 1 14 27001005S Engine Flange 1 1 100074-01 Top Cover
Résumé du contenu de la page N° 19
OWNER’S MANUAL 23 ILLUSTRATED PARTS LIST FOR MODELS RGH5500, RGH5500IE, AND RGH7500IE 25 24 ALTERNATOR ASSEMBLY 22 9 15 21 This list contains replaceable parts used in your generator. When ordering parts, fol- 20 19 low the instructions listed under Replace- 9 10 ment Parts on page 17 of this manual. 8 14 7 18 6 5 13 16 12 4 1 17 2 11 3 PART NUMBER FOR MODEL KEY RGH5500 NO. RGH5500IE RGH7500IE DESCRIPTION QTY. 099723-02 099723-04 Alternator Assembly 1 1 099844-01 099844-01 End Cover 1 2 099701-0
Résumé du contenu de la page N° 20
® PORTABLE GASOLINE GENERATORS 19 ILLUSTRATED 18 PARTS LIST 20 8 13 FOR MODEL RGH11000IE 17 ALTERNATOR ASSEMBLY 15 21 This list contains replaceable parts used in 26 your generator. When ordering parts, follow the instructions listed under Replacement 10 Parts on page 17 of this manual. 12 24 14 5 11 23 25 1 2 6 4 16 22 9 7 3 KEY PART NO. DESCRIPTION NUMBER QTY. 1 Stator * 1 2 Rotor * 1 3 Draw Bolt 103188-01 1 4 Fan 103191-01 1 5 Balancing Disc 103192-01 1 6 Lifting Eyes 103193-01 2 7 D.E. Brac