Operator’s Manual
Manual del Operario
5550 WATTS
Model / Modelo
8550 STARTING WATTS
030235-01
WARNING ADVERTENCIA
Failure to read and follow the operator’s manual and all Si no se leen y siguen las indicaciones del Manual del
operating instructions can result in death, bodily injury, Operario y todas las instrucciones de uso, se pueden
and/or property damage. producir daños materiales, lesiones o incluso la muerte.
Manual No. 199408GS
SAVE THESE INSTRUCTIONS
Revision - (06/15/2006)
Résumé du contenu de la page N° 2
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them. Because Briggs & Stratton does not necessarily kn
Résumé du contenu de la page N° 3
Table of Contents Safety Rules .................................................................2 Equipment Description..............................................................................4 Assembly .....................................................................4 Unpack Generator......................................................................................4 Shipment Contents.....................................................................................4 Install Wheel
Résumé du contenu de la page N° 4
SAVE THESE INSTRUCTIONS Safety Rules This is the safety alert symbol. It is used to Using a generator indoors WILL KILL YOU alert you to potential personal injury IN MINUTES. hazards. Obey all safety messages that follow this symbol to avoid possible injury or Exhaust contains carbon monoxide, a death. poison gas you cannot see or smell. The safety alert symbol ( ) is used with a signal word (DANGER, WARNING, CAUTION), a pictorial and/or a safety message to alert you to hazards. DANGER indic
Résumé du contenu de la page N° 5
WARNING WARNING Rapid retraction of starter cord (kickback) will � This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications. pull hand and arm toward engine faster than � Failure to use the appropriate U. S. Coast Guard approved you can let go. generator could result in death or serious injury and/or property Broken bones, fractures, bruises or sprains damage. could result. � When starting engine, pull cord slowly until resistance is felt
Résumé du contenu de la page N° 6
Equipment Description CAUTION Read this manual carefully and become Exceeding generators wattage/amperage capacity can familiar with your generator. Know its damage generator and/or electrical devices connected applications, its limitations and any hazards to it. involved. � DO NOT exceed the generator’s wattage/amperage capacity. See The generator is an engine–driven, revolving field, Don’t Overload Generator in the Operation section. alternating current (AC) generator. It was designed to Every
Résumé du contenu de la page N° 7
5. Install e-ring with pliers, squeezing from top of e-ring Type of Fuel to bottom of axle. 1. Always use clean, fresh, unleaded gasoline with a 6. Repeat steps 4 and 5 to secure second wheel. minimum of 87 octane/87 AKI (91 RON) with equipment. DO NOT mix oil with fuel. DO NOT 7. Tip generator so that engine side is down. modify the engine fuel system or carburetor to run on 8. Line up holes in support leg (E) with holes in alternative fuels. generator frame. NOTE: Fuel with up to 10% ethanol (
Résumé du contenu de la page N° 8
System Ground Generator Location The generator has a system ground that connects the Clearances and Air Movement generator frame components to the ground terminals on WARNING the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded Exhaust heat/gases can ignite combustibles, to the generator frame). structures or damage fuel tank causing a fire. Special Requirements � Keep at least 5 ft. (152 cm) clearance on all sides of generator There may be Fede
Résumé du contenu de la page N° 9
Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. M L G K H D E A C I J B F A - 120 Volt AC, 20 Amp, Duplex Receptacles — F - Double Pole Circuit Breaker (AC) — A double May be used to supply electrical power for the pole circuit breaker is provided to protect all the operation of 12
Résumé du contenu de la page N° 10
120 Volt AC, 20 Amp, Duplex Receptacles Receptacles Both duplex receptacles (Figure 5) are protected against CAUTION overload by a double pole rocker switch circuit breaker. Receptacles may be marked with rating value greater than generator output capacity. � NEVER attempt to power a device requiring more amperage than generator or receptacle can supply. � DO NOT overload the generator. See Don’t Overload Generator in the Operation section. 120/240 Volt AC, 30 Amp, Locking Receptacle Use a NEMA
Résumé du contenu de la page N° 11
Operation WARNING Rapid retraction of starter cord (kickback) will Starting the Engine pull hand and arm toward engine faster than you can let go. Disconnect all electrical loads from the generator. Use the Broken bones, fractures, bruises or sprains following start instructions: could result. 1. Make sure unit is on a level surface. � When starting engine, pull cord slowly until resistance is felt and IMPORTANT: Failure to start and operate the unit on a then pull rapidly to avoid kickback. lev
Résumé du contenu de la page N° 12
Connecting Electrical Loads Stopping the Engine 1. Let engine stabilize and warm up for a few minutes 1. Turn OFF and unplug all electrical loads from after starting. generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned 2. Plug in and turn on the desired 120 and/or 240 Volt ON. AC, single phase, 60 Hz electrical loads. 2. Let engine run at no-load for several minutes to NOTE: stabilize internal temperatures of engine and � DO NOT connect 240 Volt
Résumé du contenu de la page N° 13
6. Repeat steps 4 and 5 for each additional load. Don’t Overload Generator Capacity Rated* Additional Tool or Appliance (Running) Surge (Starting) You must make sure your generator can supply enough Watts Watts rated (running) and surge (starting) watts for the items you Essentials will power at the same time. Follow these simple steps: Light Bulb - 75 watt 75 - 1. Select the items you will power at the same time. Deep Freezer 500 500 2. Total the rated (running) watts of these items. This is Su
Résumé du contenu de la page N° 14
Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. Maintenance Schedule - Fill in Dates as You Complete Regular Service Service Dates Service Dates Before Each Every 25 Hours Every 50 Hours Every 100 Hours Maintenance Task Use or Yearly or Yearly or Yearly X Clean debris X Check oil level X¹ Change engine oil X² Service air cleaner X Service spark plug X Service spar
Résumé du contenu de la page N° 15
Generator Maintenance Oil Generator maintenance consists of keeping the unit clean WARNING and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air Unintentional sparking can result in fire or slots in the generator must not become clogged with electric shock. snow, leaves, or any other foreign material. NOTE: DO NOT use water or other liquids to clean When adjusting or making repairs to yo
Résumé du contenu de la page N° 16
SAE 30: 40 °F and higher (5 °C and higher) is good for all Changing Engine Oil purpose use above 40°F, use below 40°F will cause hard Change the oil after the first 5 hours of operation. Change starting. oil every 50 hours thereafter. If you are using your 10W-30: 0 to 100 °F (-18 to 38 °C) is better for varying generator under extremely dirty or dusty conditions, or in temperature conditions. This grade of oil improves cold extremely hot weather, change the oil more often. weather starting, b
Résumé du contenu de la page N° 17
Service Air Cleaner Service Spark Plug Your engine will not run properly and may be damaged if Change the spark plug every 100 hours of operation or you run it with a dirty air cleaner. once each year, whichever comes first. This will help your engine to start easier and run better. Replace the air cleaner every 25 hours of operation or once each year, whichever comes first. Replace more often 1. Clean area around spark plug. if operating under dirty or dusty conditions. 2. Remove and inspect sp
Résumé du contenu de la page N° 18
Engine Air Cooling System WARNING Over time debris may accumulate in cylinder cooling fins Running engines produce heat. Temperature of and cannot be observed without partial engine disassembly. muffler and nearby areas can reach or exceed For this reason, we recommend you have an authorized 150°F (65°C). Briggs & Stratton service dealer clean the cooling system Severe burns can occur on contact. (Figure 15) per recommended intervals (see Maintenance Exhaust heat/gases can ignite combustibles, S
Résumé du contenu de la page N° 19
Change Oil Storage While engine is still warm, drain oil from crankcase. Refill The generator should be started at least once every seven with recommended grade. days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than Oil Cylinder Bore 30 days, use the following guidelines to prepare it for � Remove spark plug and pour about 1/2 ounce (15 ml) storage. of clean engine oil into the cylinder. Generator Storage � Install spark plug and pull start
Résumé du contenu de la page N° 20
Troubleshooting Problem Cause Correction 1. One of the circuit breakers is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord set. 3. Check and repair. AC output is available. 4. Connected device is bad. 4. Connect another device that is in good condition. 1. Short circuit in a connected load. 1. Disconnect shorted electrical load. 2. Engine speed is too slow. 2. Contact authorized service