Model HQC45 Model HQCF45 QuickChill QuickChill / Freezer Model HQC90 QuickChill With Legs With Casters Table of Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Legs
Résumé du contenu de la page N° 3
Installation, Operation, Use and Care of HQC45 QuickChill, HQCF45 QuickChill / Freezer, & HQC90 QuickChill SAVE THESE INSTRUCTIONS GENERAL The HQC45 QuickChill is designed for rapid chilling of 45 pounds of food (9 pounds of food per pan 1 in five 12" x 20" x 2 ⁄2" pans or five 18" x 26" sheet pans) from 150°F to 37°F in approximately 90 minutes. The rapid chilling process preserves food quality, texture and nutritional value for up to 5 days. As many as 5 chillings can be handled per 8 hour sh
Résumé du contenu de la page N° 4
INSTALLATION Before installing, check the electrical service to make sure it agrees with the electrical specifications on the rating plate located inside the cabinet. UNCRATING Immediately after unpacking, check for possible shipping damage. If the chiller is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. DO NOT LAY THE CHILLER ON ITS FRONT, BACK OR SIDES. EXERCISE EXTREME CARE WHEN REMOVING THE CRATE BOTTOM ESPECIALLY WHEN THE LAST SHIPPIN
Résumé du contenu de la page N° 5
LOCATION Good air circulation at the condenser coil in the lower section is necessary to provide proper operation. The cabinet may be located in any one of the following three ways to assure satisfactory performance. • The unit can be situated so the lower back section is open to room air, allowing free air discharge. No side clearance and no top clearance is required. This is the preferred situation and provides the most effective cooling. • The unit can be provided with no side clearance, two
Résumé du contenu de la page N° 6
ELECTRICAL CONNECTIONS Line voltage supplied to the cabinet junction box must not be affected by the operation of other electrical equipment. Junction box is located at the rear of the lower section. The rear compressor cover is maintained in place with Velcro. Pull to remove it. WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG
Résumé du contenu de la page N° 7
OPERATION Display Main Switch Keypad STOP 12 3 NO START 45 6 YES OFF ON PRINT 78 9 # Key is used as "–" sign to enter negative numbers. CLEAR MUTE #0 Silences the Buzzer Printer Slot Fig. 4 0. MAIN MENU Displays on initial power up. Cabinet is idle. The Main Menu displays the time of day in the upper left corner. 10:35 1.CHLL 2.FRZE On the Chiller/Freezer cabinet, five menu options allow you to 3.DEFR 4.HOLD 5.SET select Chill, Freeze, Defrost, Hold or Set-Up. 10:35 1.CHLL Chiller only M
Résumé du contenu de la page N° 8
1.1 AUTOMATIC CHILL —(Controlled by probes, a non-timed chill.) From the main menu, press [1][1]. AUTOMATIC CHILL To begin Automatic Chill, press [YES]. OK TO START [YES/NO] The top row displays the food probe temperatures. The left value corresponds to the top probe; the right value corresponds to the Top Bottom bottom probe, etc. The temperature of the air, the AUTO mode Probe Probe indicator, and the chill cycle time are displayed on the bottom row. 34 45 37 The compressor operat
Résumé du contenu de la page N° 9
2. FREEZE MODE — From the main menu, press [2], when available. Freeze mode operates exactly like chill mode. Use the menus on page 7 except CHILL is replaced by FREEZE. Different target FREEZE METHOD:1.AUTO temperature and air set point may be entered in Set-Up Mode. 2.MANUAL 3.EXIT Different temperature ranges are available for chill and freeze modes. After a Freeze cycle is complete, the cabinet goes into Freezer Hold mode. 3. DEFROST MODE — From the main menu, press [3]. To begin a
Résumé du contenu de la page N° 10
5. SET UP MODE — From the main menu, press [5]. Set Up mode allows you to easily set four parameters for HQC45, HQC90; seven parameters for HQCF45. These parameters could be set according to the type of food, its surface, etc. The user may try different set ups to maximize performance and food quality. On a chiller only model, the grayed freezer temperatures setup menus are omitted. Blasting air differential and holding air differential temperatures are set at the factory. The setting for ta
Résumé du contenu de la page N° 11
The setting for the air temperature in freezer hold mode is shown. HOLDING FREEZER Air temperature will be maintained between the holding temperature TEMPERATURE: -6 and holding temperature plus differential. For Example: Holding Freezer Temperature = –6°F. Differential = 6 F°. Temperature will fluctuate between –6°F and 0°F. T. emperature Range Preset Holding Freezer Temp FF reezer Hold Mode–F 32° F to 20° – 6° Enter a value within the range. Press [YES] to continue. This applies onl
Résumé du contenu de la page N° 12
MAINTENANCE CLEANING Wash, rinse, and sanitize the product probes before and after use as you would any food- contact utensil that measures temperature. Chiller surfaces of stainless steel should be wiped clean with a damp cloth or mild cleaning solution. DO NOT flush with running water. Buzzer Avoid the use of solvents around plastic or painted areas; clean these with a damp cloth moistened with a solution of mild detergent and Buzzer Loudness Service Switch Adjustment Screw warm water. Clean