Résumé du contenu de la page N° 1
POWER TIMER QUIET POWERFUL
F565374
Operating Instructions
Air Conditioner
CS-W12EKR CU-W12EKR
ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Manufactured by:
© 2006 Panasonic HA Air-Conditioning (M) Sdn Bhd
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site,
and distribution is a violation of law.
40300 Shah Ala
Résumé du contenu de la page N° 2
Thank you for purchasing Panasonic Air Conditioner SAFETY PRECAUTIONS ■ Definition To prevent personal injury, injury to others, or property Warning damage, please observe During Installation During Installation the following. • Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric Incorrect operation due to shock or fi re. Please consult an authorized dealer or specialist for the installation work. failure to follow instructions • This
Résumé du contenu de la page N° 3
REGULATORY INFORMATION ■ Operation Condition The appliance is not intended for use by young children or the infi rm person without supervision. Use this air conditioner under the Young children should be supervised to ensure that they do not play with the appliance. following temperature range. Indoor E En nv vir iro onmental R nmental Re equir quire ements ments Temperature (°C) *DBT *WBT Maximum 32 23 COOLING Minimum 16 11 Battery Disposal Maximum 30 – HEATING The batteries must be recycled
Résumé du contenu de la page N° 4
FAN AUTO SPEED HEAT AIR COOL SWING DRY OFF OFF ON TIMER TIMER OFF/ON MODE QUIET FAN SPEED TEMP POWERFUL AIR SWING TIMER ON SET 123 OFF CANCEL SET RESET CLOCK PRODUCT OVERVIEW ■ About Remote Control Preparation Air intake I Indoor Unit ndoor Unit 1. Pull out the cover. Supersonic air purifying device Front panel Auto OFF/ON 2. Insert AAA or R03 button batteries. 3. Close the cover. 4. Press CLOCK. TIMER ER Receiver 5. Press to ON SET SET set time. Air filter 13 2 2 OFF CANCEL SET R
Résumé du contenu de la page N° 5
AUTO, HEAT, COOL, DRY ■ Operation Details AUTO - Automatic Operation • Unit selects the operation mode according to the room temperature. • Once the operation mode is selected, the unit will operate at the standard setting temperature as shown: Standard Room Operation setting temperature mode temperature FAN 23°C & AUTO Cool 25°C SPEED above HEAT AIR COOL 2 2 SWING Below DRY Dry 22°C 1 1 23°C OFF Select the Below OFF ON Heat 21°C TIMER TIMER Start the 20°C desired operation. OFF/ON
Résumé du contenu de la page N° 6
FAN SPEED, AIR SWING ■ Operation Details • There are 3 fan speeds, as well as automatic*. * For automatic fan speed, the speed of the indoor fan is automatically adjusted according to the operation. Select fan speed. FAN AUTO • Keeps the room ventilated. SPEED HEAT AIR • There are 5 options for vertical COOL SWING airfl ow direction. DRY OFF • If automatic vertical airfl ow OFF ON direction has been set, the louvers TIMER TIMER swing up and down automatically. OFF/ON • For HEATIN
Résumé du contenu de la page N° 7
POWERFUL, QUIET ■ Operation Details • To reach the desired set temperature quickly. It will operates for 15 minutes and returns to the desired setting. • To provide a quiet surrounding. FAN AUTO SPEED HEAT AIR COOL SWING DRY Enables OFF quiet OFF ON ■ Hint TIMER TIMER • To reduce power consumption operation. OFF/ON during cooling operation, close the MODE curtains to prevent the sunlight and heat from coming in. QUIET FAN SPEED TEMP POWERFUL AIR SWING TIMER ON SET 123 Enables p
Résumé du contenu de la page N° 8
TIMER ■ Operation Details • The timer allows you to turn the air conditioner on or off automatically. • The unit may start in preliminary operation before the actual set time when ON timer has been set. • The set timer repeats daily once set. • If there is a power failure, you can restore the previous setting (once 2 2 power is resumed) by pressing the button. Set the • If the timer is cancelled, press AUTO FAN to restore the previous setting. SPEED desired time. HEAT AIR 1
Résumé du contenu de la page N° 9
CARE & CLEANING ■ Washing Instructions • Do not use benzene, thinner or Switc Switch h of off f the po the pow wer suppl er supply y scouring powder. b bef efor ore e c cleaning leaning • Use only soaps ( pH7) or neutral ≃ household detergen. • Do not use water hotter than 40°C. FR FRO ONT P NT PANEL ANEL INDOOR UNIT Raise and pull to remove. • Wipe the unit gently with a soft, dry Wash and dry. cloth. AIR FILTER AIR FIL AIR FILTER TER • Air fi lters cleaning is needed every two weeks. Vac
Résumé du contenu de la page N° 10
SEASONAL INSPECTION AFTER EXTENDED NON-USE: • Checking of remote control batteries. • No obstruction at inlet and outlet vents. • After 15 minutes of operation, it is normal to have the following temperature difference between inlet and outlet vents: Cooling: ≥ 8°C Heating: ≥ 14°C 10
Résumé du contenu de la page N° 11
NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions: • Abnormal noise during operation. • Circuit breaker switches off frequently. • Water/foreign particles have entered the Remote Control. • Power cord becomes unnaturally warm. • Water leak from Indoor unit. • Switches or buttons are not functioning properly. 11 ENGLISH
Résumé du contenu de la page N° 12
Printed in Malaysia Matsushita Electric Industrial Co., Ltd. Web Site: http://www.panasonic.co.jp/global/ F565374 OPTH0604-00