Résumé du contenu de la page N° 1
www.regency-fi re.com
Owners &
Freestanding Woodstove
Installation Manual
MODELS: F2400M S2400M
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
918-154b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 01/18/07
Résumé du contenu de la page N° 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fi re may result. For your safety, follow the instal- lation instructions, contact local building,
Résumé du contenu de la page N° 3
TABLE OF CONTENTS THE REGENCY FREESTANDING WOOD STOVE SAFETY LABEL MAINTENANCE Safety Label for F2400m ...............................................4 Maintenance ................................................................ 21 Safety Label for S2400M ...............................................5 Creosote ...................................................................... 21 Maintenance OfGold-plated Doors ..............................21 Latch Adjustment ..............................
Résumé du contenu de la page N° 4
SIDE SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Freestanding Woodstove (F2400M). improved. Check the label on the unit and if We have printed a copy of the contents here there is a difference, the label on the unit is the for your review. correct one. SAFETY LABEL FOR F2400M BACK M O L K FRONT Regency Freestanding Woodstove 4 SIDE
Résumé du contenu de la page N° 5
SIDE SAFETY LABEL This is a copy of the label that accompanies NOTE: Regency units are constantly being improved. Check the label on the unit and if each Regency Medium Freestanding Step Stove (S2400M). We have printed a copy of there is a difference, the label on the unit is the the contents here for your review. correct one. SAFETY LABEL FOR S2400M DO NOT REMOVE THIS LABEL LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE HOME INSTALLATION 245 MODEL: REGENCY MEDIUM FREES
Résumé du contenu de la page N° 6
INSTALLATION UNIT DIMENSIONS 27-3/8” (695mm) 24-7/8” (632mm) 6-5/8” (168mm) 24” (610mm) Regency Freestanding Woodstove 6 30-3/8" (772mm) 29-1/8" (740mm)
Résumé du contenu de la page N° 7
INSTALLATION even reduced heat output. Too tall a chimney 10) In seismically active areas, Regency rec- RESIDENTIAL may prompt excessive draft which can result ommends that your unit is secured to the in very short burn times and excessive heat fl oor by using the bolt down holes inside INSTALLATION output. The use of an inexpensive fl ue pipe the pedestal (the same ones used in Mobile damper may be helpful in reducing excessive Home installations). 1) Please read this entire manual before you
Résumé du contenu de la page N° 8
INSTALLATION On pedestal units there are two locations where Note: Once the knockout is removed there ROOM AIR outside air may be adapted to the unit. If us- are two tabs remaining. Bend both ing the bottom of the pedestal, do not remove tabs out for ease of installation when IMPORTANT knockout from the rear of the pedestal. Only attaching outside air. For installation using room air for combustion, remove rear knockout if outside air will be remove knockout from the pedestal, and/or from
Résumé du contenu de la page N° 9
INSTALLATION Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36" From From Flue Min. Min.Hearth Unit Unit Center-line
Résumé du contenu de la page N° 10
INSTALLATION Rear Heat Defl ector Pedestal Assembly STOVE ASSEMBLY Assembly for F2400M F2400M & S2400M PRIOR TO (815-555) (020-915) INSTALLATION The rear heat defl ector is supplied with the stove 1) For easier assembly, tip the stove on its All units require either the pedestal or 4 legs at- and must be installed unless the optional airmate back (onto a soft surface to prevent scratch- tached to the base. The F2400M stove requires has been selected. It stops the heat radiated from ing). ei
Résumé du contenu de la page N° 11
INSTALLATION 8) To complete your chimney installation, install Leg and Bottom Shield Assembly STEP-BY-STEP the double wall connector pipe from the F2400M & S2400M stove’s fl ue collar to the chimney support CHIMNEY AND device. Bottom Shield 020-911 CONNECTOR 9) If you are using a horizontal connector, Legs (set of 4) INSTALLATION the chimney connector should be as high Steel - Painted Black 850-125 as possible while still maintaining the 18" Cast - Painted Black 850-126 Note: The
Résumé du contenu de la page N° 12
INSTALLATION MASONRY CHIMNEY Ensure that a masonry chimney meets the mini- mum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. MASONRY FIREPLACE There are listed kits availabl
Résumé du contenu de la page N° 13
INSTALLATION COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS Method A: 12" (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specifi cation for Clay Fire Linings) or its equivalent. Keep a minimum of 12" (304.8 mm) of brick masonry between the clay liner and wall combustibles. The clay liner shall run from th
Résumé du contenu de la page N° 14
INSTALLATION RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft (refer to Table 1). 3) Add 4% overall for each 1000' above sea Recommended Flue Height level. Elevation Example a) Example b) 0' 18' 21' 1) At sea level minimum height is 12' straight. Example: a) 1000' 18.72' 21.84' 1-1/2 ft. of horizontal run = 3 ft. 2000' 19.44' 22.68' 2) Add the following vertical height to compen- one "T" = 3 ft. 5000' 21.60' 25.20' sate for: Total Addition (at sea le
Résumé du contenu de la page N° 15
INSTALLATION MOBILE HOME INSTALLATION In addition to standard installation instructions Once you have properly marked the position of your unit and the fl oor protection as outlined in the following requirements are mandatory for the Residential Installation items #1 through #8, installation in a mobile home. a supply of fresh air has to be supplied to your unit. Cut a minimum 4" (102mm) diameter hole 1) The stove must be permanently bolted to the fl oor of the Mobile Home using the fl oor th
Résumé du contenu de la page N° 16
INSTALLATION SIMPSON DURA-PLUS Slide the tube into the left hand side, as far LISTED COMPONENTS Qty.Part # Description as possible and then bring it back into the 1 6DVL8693 Connector Kit hole on the right hand side until it locks into FOR MOBILE HOME 1 6DP-MH9096 Mobile Home Kit position. If the tube will not slide in easily, INSTALLATION simply use a pair of vise grips or pliers and ICC EXCEL 2100 tap it into place with a hammer. A tighter fi t The Regency F2400M and S2400M Freestand-
Résumé du contenu de la page N° 17
INSTALLATION 4) Push the ash plug into the hole inside the BRICK INSTALLATION STEP-BY-STEP fi rebox and replace all the bricks except for the brick over the ash plug (see brick OPTIONAL Firebrick is included to extend the life of your diagram in the Brick Installation section). stove and radiate heat more evenly. Check to ACCESSORIES see that all fi rebricks are in their correct posi- 5) Place the ash plug tool beside the lid, then tions and have not become misaligned during INSTALLATION s
Résumé du contenu de la page N° 18
White Low (Red) High (Black) INSTALLATION Blower/Fan (846-515) 1) Remove the two screws from the top of the fan housing. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the two screws removed earlier. CAUTION: The connection cord should not be in contact with any hot surfaces. Do not route cord under or in front of unit. Read the Fan Operation instructions before using. Neutral Green Manual/ Live Ground Fan Auto 120V AC
Résumé du contenu de la page N° 19
OPERATING INSTRUCTIONS 9) During the fi rst few days it may be more OPERATING FIRST FIRE diffi cult to start the fi re. As you dry out your fi rebrick and your masonry fl ue, your draft INSTRUCTIONS When your installation is completed and in- will increase. spected you are ready for your fi rst fi re. With your unit now correctly installed and safety 10) For those units installed at higher elevations inspected by your local authority, you are now 1) Open control fully. or into sub-standard masonr
Résumé du contenu de la page N° 20
OPERATING INSTRUCTIONS Push the ashes down the hole into the ash 4) If you have smoke detectors, prevent smoke FAN OPERATION drawer, the large pieces can be left in the spillage as this may set off a false alarm. fi rebox and burned during the next fi re or Automatic removed through the door opening. 5) Do not overfi re heater. If the chimney con- To operate the fan automatically, push the bot- nector, fl ue baffl e or the stove top begin to tom switch on the side of the fan housing to 2) Always