Résumé du contenu de la page N° 1
DO NOT
DISCARD
R
CLASSIC BAY 1200 PELLET STOVE
Portland
Tested and
O-T L
Listed by Oregon USA
Owner’s Manual
C US
OMNI-Test Laboratories, Inc.
Installation and Operation
Model:
CB1200M-MBK
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and • Leave this manual with
• Important operating and
follow these instruc- party responsible for use
m aint enanc e ins t ruc-
tions for safe installa- and operation.
tions included.
tion and operation.
WARNING
WARNING
Please
Résumé du contenu de la page N° 2
R CB 1200 Pellet Stove and Welcome to the Quadra-Fire Family! and fireplaces. And yet we are old-fashioned when it comes to Hearth & Home T echnologies welcomes you to our tradition of craftsmanship. Each unit is meticulously fabricated and surfaces excellence! In choosing a Quadra-Fire appliance, you have are hand -finished for lasting beauty and enjoyment. Our pledg e our assurance of commitment to quality , durability , and perfo
Résumé du contenu de la page N° 3
R CB 1200 Pellet Stove Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury . • NOTICE: Indicates practices which may cause damage to the fireplace or to property . TABLE OF CONTENTS Section 7: Appl
Résumé du contenu de la page N° 4
R CB 1200 Pellet Stove Listing and Code Approvals 1 A. Appliance Certification E. BTU & Efficiency Specifications Model CB1200 Pellet Stove Emissions Rating 0. 9 grams/hr . Laboratory OMNI T est Laboratories, Inc. *BTU Output 14,000 - 40,000 / hr Report No. 061-S-21-4 Heating Capacity up to 2,500 sq. ft. depending on climate zone Type Solid Fuel Room Heater/Pellet Fuel Hopper Capacity 80 lbs BurningT ype Fuel W ood Pellets or Shelled Corn Standard ASTM E1509-95, ULC S627-M93 and Shipping
Résumé du contenu de la page N° 5
R CB 1200 Pellet Stove Getting Started 2 A. Design, Installation & Location Consider- Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: ations • Windows 1. Appliance Location • Air Intakes NOTICE: Check building codes prior to installation. • Air Conditioner • Installation MUST comply with local, regional, state and national codes and regulations. • Overhang, soffits, porch roofs, adjacent walls • Consult insurance carrier , l
Résumé du contenu de la page N° 6
R CB 1200 Pellet Stove B. Locating Your Appliance & Chimney E. Negative Pressure WARNING! Risk of Asphyxiation! Negative pressure can Location of the appliance and chimney will af fect cause spillage of combustion fumes and soot. performance. • I ns t all t hr ough t he warm airs pace enc los ed by t he building Negative pressure results from the imbalance of air avail- envelope. This helps to produce more draft, especially able for the appliance to ope
Résumé du contenu de la page N° 7
R CB 1200 Pellet Stove F. Fire Safety G. Tools And Supplies Needed T o p ro vi d e re a so n a b l e fire sa fe ty , th e fo l l ow i ng sh o u l d b e Tools and building supplies normally required given serious consideration: for installation, unless installing into an existing • Install at least one smoke detector on each floor of your masonry fireplace: home. Safety Glasses Reciprocating Saw • Locate smoke detector away from the heating appliance Frami
Résumé du contenu de la page N° 8
R CB 1200 Pellet Stove Dimensions and Clearances 3 A. Appliance Dimensions 4-5/8 in 20- 7/16 in. 8-1/6 in. (118mm) (519mm) (205mm) 12-3/8 in (314mm) 14-1/4 in C L (362mm) 5.0 in 2-1/2 in C (127mm) L (64mm) 25-3/4 in. 27-5/8 in. (654mm) (692mm) 28-1/2 in. (724mm) Figure 8.2 - Top View with Top Vent Adapter Figure 8.1 - Top View 28-1/2 in. 25-3/4 in. (724mm) (629mm) 31-5/8 in. (803mm) C L 10-3/4 in. 8-1/16 in. (273mm) (205mm) 24-3/4 in. 26-1/2 in. (629mm) (673mm) Figure 8.3 - Side View Figure
Résumé du contenu de la page N° 9
R CB 1200 Pellet Stove B. Clearances to Combustibles (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Minimum Alcove Width 40-1/2 1029 A C Maximum Alcove Depth 36 915 Minimum Alcove Side W all 6 152 T op of Unit to Combustibles 12-1/2 318 B C WARNING Fire Risk. Inches Millimeters Straight Back Against Comply with all minimum clearances to Wall combustibles as specified. Back W all to Appliance 2 51 A Failure to comply may cause house fire. Side W all to
Résumé du contenu de la page N° 10
R CB 1200 Pellet Stove C. Hearth Pad Requirements (UL and ULC) Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door. L* K K M Figure 10.1 Inches Millimeters Hearth Pad Requirements Sides 2 51 K Back 2 51 L* Front 6 152 M *L Exception for Horizontal Installations: USA INSTALLATIONS : A non-combustible floor protec- tion is recommended
Résumé du contenu de la page N° 11
R CB 1200 Pellet Stove Vent Information 4 B. Venting Termination Requirements A. Chimney and Exhaust Connection 1. Chimney & Connector : Use 3 or 4 inch (76-102mm ) diameter type "L" or "PL" venting system. It can be vented CAUTION vertically or horizontally . Do not terminate vent in any enclosed or semi-enclosed 2. Mobile Home: A p pr ov ed f or all Lis t ed pellet v e nt . I f us ing area such as a carport, garage, attic, crawl space, under a the
Résumé du contenu de la page N° 12
R CB 1200 Pellet Stove WARNING C. Equivalent Feet of Pipe Improper installation, adjustment, alteration, service or The table belo w can help you calculate the equivalent feet maintenance can cause injury or property damage. Refer of pipe which is a method used to determine pellet vent size. to the owner ’ s information manual provided with this a p p l i- Figure 12.1. ance. For assistance or additional information consult a qualified installer , service agenc
Résumé du contenu de la page N° 13
R CB 1200 Pellet Stove Venting Systems 5 A. Alcove A C D B Figure 13.1 Inches Millimeters Alcove Installation Minimum Alcove Height 44 1117 A Minimum Alcove Width 40-1/2 1029 B Maximum Alcove Depth 36 915 C Minimum Alcove Side W all 6 152 D not shown T op of Unit to Combustibles 12-1/2 318 All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . • I llustrations/diagrams are not drawn to scale. • Actual
Résumé du contenu de la page N° 14
R CB 1200 Pellet Stove B. Through The Wall NOTE: Horizontal termination cap must be a minimum of 12 inches. In Canada, where passage through a wall or partition of (305mm) from the wall. Approved for mobile home instal- combustible construction is desired, the installation shall lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed conform to CAN/CSA-B365 pellet venting or listed double wall pipe and a Quadra-Fire outside air
Résumé du contenu de la page N° 15
R CB 1200 Pellet Stove C. Vertical into Existing Class A Chimney W e recommend a minimum of 60 in. (1.5m) vertical, Rain Cap however above the eave is preferred. Both installatio ns are approved for mobile home instal- lations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pell et venting or listed double wall pipe and Flashing 24 in. (610mm) Quadra-Fire outside air kit in mobile homes. Single minimum wall pipe is approved for res
Résumé du contenu de la page N° 16
R CB 1200 Pellet Stove WARNING Fire Hazard Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFP A 21 1 • Factory-built chimney must be minimum6 in. (152mm) UL103 HT . E. Masonry Fireclay Flue Concrete Cap Liner with Airspace Flashing 1 in. (25mm) Clearance with Firestop 1 in. (25mm) Clearance 3 in. (76mm) Minimum 6 in. (152mm) Sheathing Minimum Cleanout Cover Airtight Clean-out Door Non-Combustible Hearth Pad Figure 16.1 F. Alternate Masonr
Résumé du contenu de la page N° 17
R CB 1200 Pellet Stove Mobile Home 6 A. Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit THE STRUCTURAL INTEGRITY OF THE MANUFAC- for installation in a mobile home. TURED HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. 1. An outside air inlet must be provided f or t he combust ion Do NOT cut through: air and must remain clear of leaves, debris, ice and/or • Floor joist, wall, studs or ceiling trusses. snow . It must be unrestricte
Résumé du contenu de la page N° 18
R CB 1200 Pellet Stove Appliance Set-Up 7 A. Outside Air Kit Instructions 2. Floor Installation a. Remove rear screen and set aside. Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose b. Install cover plate over hole in right rear floor. clamps, 1 collar assembly , termination cap assembly , 1 trim ring, 12 screws. c. Cut a 2 inch minimum hole in the floor to accommodate Tools Needed: Phillips head screw driver; wire cutters; flex hose. hole saw or jig saw . d.
Résumé du contenu de la page N° 19
R CB 1200 Pellet Stove C. Rear Vent and Rear Vent to Top Vent B. Top Vent Adapter Installation Adapter Installation 3 to 3 inch Top Vent Adapter 3 to 6 inch Top Vent Offset Adapter Installing the Top Vent Adapter 1. Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet. 2. Slide the top vent adapte r onto the rear exhaust outlet and adjust the assembly to a vertical position. 3. Drill 4 hole s with #26 drill bit (provided) into the b
Résumé du contenu de la page N° 20
R CB 1200 Pellet Stove E. Brick Clip Installation D. Optional Brick Set Installation 1. Remove the baffle first, follow instructions on page 34 . WARNING 2. Slide bottom of left rear brick in first; rotate top edge Risk of Injury . toward rear of appliance and then rotate outer edge • Brick may have small wires protruding from toward rear of appliance, until brick slides into place. the back of brick. Figure 20.1. 3. Repeat with righ