Résumé du contenu de la page N° 1
Astoria™
Pellet Stove
• Horizontal Or Vertical Vent
• Freestanding Stove
• Mobile Home Approved
• Class A Chimney Retrofit
• Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
Tested and Listed by
Omni-Test Laboratories, Inc.
Portland, Oregon
Report # 028-S-42-2
ASTM E1509-2004
-- Please read this entire manual before installation and use of this pellet fuel-
burning room heater. Failure to follow these instructions could result in property
damage, bodily injury,
Résumé du contenu de la page N° 2
2 Introduction Introduction We welcome you as a new owner of an Astoria pellet heater. In purchasing an Astoria you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Astoria is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this pellet-burning heater. Please familiarize yourself with the Owner's Manual before operat
Résumé du contenu de la page N° 3
Table of Contents 3 Introduction Operation (continued) Introduction......................................................2 Manual Mode.....................................................22 Important Information .........................................2 Auto Mode........................................................23 Restrictor Adjustment.........................................24 Safety Precautions Restrictor Adjustment.........................................24 Safety Precautions .........
Résumé du contenu de la page N° 4
Gas 4 Safety Precautions • Do not operate the • Contact your local building heater if you smell officials to obtain a permit smoke coming from and information on any the heater. Turn the installation restrictions or MODE switch to inspection requirements Ok "OFF", monitor your in your area. Notify your heater, and call your insurance company of this dealer. heater as well. • Never use gasoline, • The exhaust system must gasoline-type lantern fuel, be completely airtight and kerosene, charcoal
Résumé du contenu de la page N° 5
Safety Precautions 5 • The heater will not operate • This heater must be during a power outage. If connected to a standard a power outage does 115 V., 60 Hz grounded occur, check the heater electrical outlet. Do not for smoke spillage and use an adapter plug or open a window if any sever the grounding plug. smoke spills into the room. Do not route the electrical cord underneath, in front of, or over the heater. • Keep foreign objects out • When installed in a mobile ? of the hopper. home, the
Résumé du contenu de la page N° 6
6 Specifications Heating Specifications Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5 Maximum Burn Time on Low Burn** ......................................................................67.5 Hours Hopper Capacity ..............................................................................................115
Résumé du contenu de la page N° 7
Installation (For Qualified Installers Only) 7 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pellet heater and notify your insurance company before proceeding with installation. Packing List • Thermostat & Wire • Scraper Rod Tool • Brush • Spare Fuses Installation Opti
Résumé du contenu de la page N° 8
8 Installation (For Qualified Installers Only) Clearances - Straight Installation Through the Wall Installations Interior Vertical Vents A A AAAAAAAA Vent Clearance* A A A AAAAAA A 2” Minimum** A A A AAAAAA A “Tee” 3” Minimum AAAAAAAA A AAAAAA A A AAAAAA A A AAAAAA A A AAAAAA A A AAAAAA A 9” Minimum 9” Minimum A AAAAAA A A AAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAAAAAAAA A A AAAAAA A A AAAAAA A Floor Protection 6” Minimum 6” Minimum A
Résumé du contenu de la page N° 9
Installation (For Qualified Installers Only) 9 Venting the Pellet Stove • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. • USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES). • No mo
Résumé du contenu de la page N° 10
10 Installation (For Qualified Installers Only) Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc…) must be sealed with 500° F. RTV silicone. Installing the Pellet Vent Seal each vent section (including adapters, elbows, etc...) by injecting a liberal amount of 500° F. RTV silicone into the gap between sections. • Horizontal sections must
Résumé du contenu de la page N° 11
Installation (For Qualified Installers Only) 11 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the b floor (Some states do not require this; check with your local building Use the lag bolts (used department). See the illustration to secure the stove to to the right. the pallet) to screw the pedestal to the floor. • The heater must be grounded to the steel chassis of the mobile home (Some states do not requir
Résumé du contenu de la page N° 12
12 Installation (For Qualified Installers Only) Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met. • Minimum height is 60" • Maximum depth is 48" • Minimum width is 46" • Minimum clearance of 9" on each side and 3" on back Baffle Installation Install the baffles included with the stove (see page 29 for detai
Résumé du contenu de la page N° 13
Installation (For Qualified Installers Only) 13 Thermostat Installation ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). A thermostat is included with this heater (part # 99300650). Follow the directions below to install. 1 Attach the thermostat wire to the circuit board Pull the cover off the thermostat (see the illustration below). Route the wire through the back of the heater (away from any
Résumé du contenu de la page N° 14
14 Installation (For Qualified Installers Only) Installation Example: Direct "Through-the-wall" Installation Horizontal Rain Cap Type "L" Outside Air Vent 12” Minimum House Shield - prevents discoloration to outside of home - HIGHLY RECOMMENDED A AAAAAAAAAAAA A A A A A Seal each vent section (including AAAAAAAAAAAA A A A 3” Minimum adapters, elbows, Wall Thimble (note AAAAAAA A etc...) by injecting a clearance between vent and liberal amount of combustibles) A AAAAA A A 500° F. RTV si
Résumé du contenu de la page N° 15
Installation (For Qualified Installers Only) 15 Installation Example: Interior Vertical Installation AAAAAAAAAAAAAA AA AAAAAAAA AA 2” Vent Minimum Clearance* A AAAAAA A AA A AAAAAA A AA “Tee” Outside A AAAAAA A AA Air Type "L" Vent (optional) A AAAAAA A AA A AAAAAA A AA A AAAAAA A AA 9” Minimum A AAAAAAAAAAAA A AA A AAAAAAAAAAAA A AA A AAAAAAAAAAAA A A AAAAAA A Floor Protection 6” Minimum A AAAAAA A AAAAAAAA Vertical Cap 24” Minimum Storm Collar AAAAAAAAAAAAAAAA Roof Flashing AAAAAAAAAAAAAA
Résumé du contenu de la page N° 16
16 Installation (For Qualified Installers Only) Installation Example: Class A Chimney Retrofit AAAAAAAAAAAA AAAAAAAA AA 2” Vent Minimum Clearance* A AAAAAA A AA “Tee” A AAAAAA A AA Outside Air Type "L" Vent A AAAAAA A AA (optional) A AAAAAA A AA A AAAAAA A AA A AAAAAAAAAAAA A 9” Minimum AA A AAAAAAAAAAAA A AA A AAAAAAAAAAAA A Floor Protection A AAAAAA A 6” Minimum Seal each vent AAAAAAAA section (including adapters, elbows, AAAAA etc...) by injecting a A AAAAAA A liberal amount of 500°
Résumé du contenu de la page N° 17
Installation (For Qualified Installers Only) 17 Installation Example: Masonry Fireplace Hearth Stove Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAAA AAAA AAAAAAAA AA AAAAA AAAAAAAAAA AAAA Seal each vent section (including AAAA AAAA AA A A AAAAA AAAA adapters, elbows, A AA A AAAA AAAA AAAAAA AAAA A AA A etc...) by injecting a A AA A AAAAAA AA A A AAAAAAA A AA A liberal amount of “L” Vent Flex 500° F. RTV AAAA AAAA AA A A AAAAA AAA
Résumé du contenu de la page N° 18
18 Installation (For Qualified Installers Only) Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove Vertical Cap Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. “L” Vent Seal each vent AA section (including AA adapters, elbows, etc...) by injecting a AAAA AA AAAA liberal amount of A AA A AA A AA A 500° F. RTV A AA A AA A AA A silicone into the gap AAAA AA AAAA between sections. AAAA AA “L” Vent Flex AAAA AA AAAAA Section Allow room for th
Résumé du contenu de la page N° 19
Installation (For Qualified Installers Only) 19 Installation Example: Freestanding Masonry Chimney Vertical Cap “L” Vent Cover Plate (non-combustible) Storm Collar Seal the cover plate with silicone. AAAAAAA AA AAAAAAA AA AAAAA AAA AA AAA AAA AAAA AAAA A A A AAAA A A AAAAA AAAA AAAAA AAAA AAAAAA AAAA AAA AAA AAAA A AA A Seal each vent A AAA AAAAAAA A A A AAAA A A AAAAAAAAA A AA A section (including adapters, elbows, AAAAA AAAA A A A AAAA A A AAAAAAA AAAA etc...) by injecting a AAAA AAAAAA A
Résumé du contenu de la page N° 20
20 Operation Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death. ! Do not unplug the stove to turn it off. This stove relies upon electricity to push the flue gases out the pellet vent – unplugging it may lead to smoke entering your room. ! Failure to maintain your heater will lead to a restricted combustion air system, leading to poo