Résumé du contenu de la page N° 1
�
�
�
�
�
�
�
�
�
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
Brookhaven
BEFORE INSTALLING AND
USING APPLIANCE
Direct Vent Model:
WARNING!
IF THE INFORMATION IN THIS
20DVT
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any
Résumé du contenu de la page N° 2
Brookhaven Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Important Curing/Burning Instructions ...............
Résumé du contenu de la page N° 3
Brookhaven Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified This appliance may be installed in an aftermarket per- installer in accordance with local building codes and with manently located, manufactured home or mobile home, current CSA-B149.1 Installation codes for Gas Burning where not prohibited by local codes. Appliances and Equipment. For USA Installations follow This appliance is only for use with the type of gas ind
Résumé du contenu de la page N° 4
Brookhaven Direct Vent Gas Fireplace 20DVT Fireplace Dimensions Rough E Opening Depth L Q K F N L O - Rough Opening Width M No drywall in this area. Rough Must use noncombustible Opening wall board such as DuraRock. Height J P D B C Gas Line Access G H A I Electrical Access Fig. 2 Fireplace specifications and framing dimensions. Ref. 20DVT A 20” (508 mm) B 29 ¹⁄₂” (749 mm) C 13 ¹⁄₂” (343 mm) D 19 ³⁄₄” (502 mm) E 14 ³⁄₄” (375 mm) 9459 20DVT specs F 15” (381 mm) 5/06 G 1 ¹⁄₂” (38 mm) H
Résumé du contenu de la page N° 5
Brookhaven Direct Vent Gas Fireplace Clearance to Combustibles Top of Unit to Ceiling ................................32” (813 mm) Front of Unit to Combustibles ...................36” (914 mm) Appliance Top of Standoff .........................................0” (0 mm) Bottom ......................................................0” (0 mm) Side .....................................................3/4” (19 mm) J I H Back .........................................................0” (0 mm) G Vent
Résumé du contenu de la page N° 6
Brookhaven Direct Vent Gas Fireplace Framing and Finishing Gas Specifications Max. Min. Air Check fireplace to make sure it is levelled Input Input Shutter Model Fuel Gas Control BTU/h BTU/h Setting and properly positioned. Sides & To mount the appliance: 20DVTRN Nat. Millivolt Hi/Lo 13,000 8,700 Bottom Half Open 1. Choose the location. Sides & 2. This unit comes with four (4) flanges pre-mounted 20DVTRP Prop. Millivolt Hi/Lo 13,000 8,700 Bottom on both sides
Résumé du contenu de la page N° 7
TP TPTH TH Brookhaven Direct Vent Gas Fireplace Remote ON/OFF Switch 1/2” Gas Supply Do not wire the remote ON/OFF wall switch for this gas 1/2” NPT x 1/2” Flare Shut- off Valve appliance into a 120v power supply. 3/8” Flex Line 1. Thread wire through the electrical knockout located (From Valve) on either side of the unit. Take care not to cut the wire or insulation on metal edges. Ensure the wire is secured and protected form possible damage. Run one end of the gas control valve and the ot
Résumé du contenu de la page N° 8
V Operable Brookhaven Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B J X B X I V K A CFM145a VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED V 1 2 Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12” (30cm) CFM145a 12” (30cm) DV Termin Location deck, or balcony 5/01/01 Rev. 12/05/01 sta B = Clearance t
Résumé du contenu de la page N° 9
Brookhaven Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner D C C F = Combustible G = 6" (152 mm) Combustible V G 6" (152 mm) Noncombustible V E 2" (51 mm) Noncombustible O V F 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4
Résumé du contenu de la page N° 10
Vertical dimension from the floor of the unit to the center of the horizontal vent pipe Brookhaven Direct Vent Gas Fireplace 30 Twist Lock Pipes 29 When using CFM Corporation twist-lock pipe it is not 28 necessary to use sealant on the joints. The only areas 27 26 of the venting system that need to be sealed with high 25 temperature silicone sealant are the sliding joints of any 24 telescopic vent section used in the system. 23 To join the twist lock pipes together, simply align the 22 beads
Résumé du contenu de la page N° 11
Brookhaven Direct Vent Gas Fireplace Example: According to the vent graph (Page 10) the Horizontal plane means no vertical rise exists on this maximum horizontal vent length in a system with a 7.5’ portion of the vent assembly. (2.3 m) vertical rise is 20’ (6 m) and if a 90° elbow is • The maximum number of 90° elbows per side wall required in the horizontal vent it must be reduced to 17’ installation is three (3). (Fig. 11) (5.2 m). In Figure 13 Dimension A plus B must not be • If a 90°
Résumé du contenu de la page N° 12
Brookhaven Direct Vent Gas Fireplace Vent Opening for Combustible Wall 9 ³⁄₈” (240 mm) Framing X X Detail 9 ³⁄₈” (240 mm) Fireplace Hearth Opening for Noncombustible Wall FP1181 Fig. 17 Vertical height requirements. 7 ¹⁄₂” (190 mm) STEP 5 VO584-100 Measure the horizontal length requirement including a Fig. 15 Locate vent opening on wall. 2” (51 mm) overlap, i.e. from the elbow to the outside wall finish plus 2”, or the distance required if installing a STEP 2 second 90° elbow. (Fig. 18) Mea
Résumé du contenu de la page N° 13
Brookhaven Direct Vent Gas Fireplace STEP 7 STEP 4 Apply high temperature sealant to 4” (102 mm) and 7” Install the 4” (102 mm) flex vent pipe to the appliance (178 mm) collars or the termination one inch away from collar as described on Page 13. Secure the end with the the end. Guide the vent termination’s 4” and 7” collars first spring 6 ³⁄₄” (172 mm) from the flex pipe end to the into their respective vent pipes. Double check that the unit. vent pipes overlap the collars by 2” (51 mm). Se
Résumé du contenu de la page N° 14
Brookhaven Direct Vent Gas Fireplace 3. Install vent system. See Page 12, Steps 2 through 5. Vertical Through-the-Roof Application 4. Ensure a watertight seal is made around the vent This gas fireplace has been approved for: pipe coming through the wall. • Vertical installations up to 40’ (12 m) in height. Up 5. Apply high temperature sealant caulking (supplied) to a 10’ (3 m) horizontal vent run can be installed around the 4” and 7” snorkel collars. within the vent system using a maximum of
Résumé du contenu de la page N° 15
Brookhaven Direct Vent Gas Fireplace Attic Insulation Shield 1 + 2 + 3 + 4 = 270° 1 1 2 2 Upper Floor 3 3 11” 11” 4 (279mm) (279mm) 4 Ceiling Installation Joist FP1179 Firestop Spacer Fig. 24 Maximum elbow usage. 4. Proceed to plumb for additional openings through the Nails (4) FP1029 roof. In all cases, the opening must provide a mini- mum of 1” (25 mm) clearance to the vent pipe, i.e., Fig. 26 Place firestop spacer(s) and secure. the hole must be at least 9 ³⁄₈” x 9 ³⁄₈” (240 x 240 mm). 5
Résumé du contenu de la page N° 16
Brookhaven Direct Vent Gas Fireplace Venting Components Starter Kit - Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) Models 7TDVTK/TV - Hot Touch Termination Kits Model 7TDVTVTK/TV - Cool Touch Termination Kit Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS -Snorkel
Résumé du contenu de la page N° 17
Brookhaven Direct Vent Gas Fireplace Operating Instructions Glass Information Machine Machine Screw Screw Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass front removed, cracked or broken. • Replacement glass (complete with gasket and Pull Left Side Latch window frame) is available through your C
Résumé du contenu de la page N° 18
Brookhaven Direct Vent Gas Fireplace 6. Place the log front (J12). Place the two underside Installation of Logs holes of the log over the two pin studs of the bracket The logs are fragile and should be handled on the left and right sides of the front burner hous- with care. Keep the packaging material out ing. (Fig. 32) of the reach of children and dispose of the 7. Place ember material on top of burner. Scatter the mterial in a safe manner. ember material over the tiles on the front area o
Résumé du contenu de la page N° 19
L O HI Brookhaven Direct Vent Gas Fireplace Large Lava Rock Flame Characteristics The large bag of lava rock provided with this fireplace It is important to periodically perform a visual check of must be placed on the firebox base around the sides of the pilot and the burner flames. Compare them to Fig- the burner assembly and on the tray beneath the grate. ures 35 & 36. If any of the flames appear abnormal call Under no circumstances should this large lava rock a service person. be placed o
Résumé du contenu de la page N° 20
F O 3 2 ON 1 T O Brookhaven Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- er’s instructions. ally. When lighting the pilot follow these instruc- • If you cannot reach your gas supplier, call tions exactly. the Fire Department B. BEFORE LIGHTING sm